Bob Kretvix replied to Paul Bowman's discussion Unknown Old Insulation
"At least you know now.  So many materials contain asbestos its probably more difficult to say it doesn't than it does.  Good luck."
Nov 28, 2012
Bob Kretvix replied to Paul Bowman's discussion Unknown Old Insulation
"All I can say is that if it isn't known and has the appearance of something that could contain asbestos (i.e., not clearly fiberglass or mineral wool, etc), OSHA requires that it be PRESUMED to contain asbestos and treated as such until negated…"
Oct 11, 2012
Bob Kretvix replied to Paul Bowman's discussion Unknown Old Insulation
"Never saw this, but looks a little like air-cell pipe insulation. This is considered Presumed Asbestos Containing Material.  You should have it tested by an accredited Asbestos Inspector before doing anything to disturb it. "
Oct 11, 2012
Bob Kretvix replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"You can also get types where you plug in the dimensions and it gives readings in cfm. "
Sep 28, 2012
Bob Kretvix replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"You really didn't answer how you use that cfm number.  Are you just comparing relative cfm values for each room, or do you have a specific cfm number that indicates excessive leakage?  If just a relative number, why not just use your…"
Sep 28, 2012
Bob Kretvix replied to Damien Herold's discussion Tired of climbing ladders and reaching to find air leaks during blower door test I have a solution!!!
"Can you explain how you would use the thermoanemometer and your criteria for air flow to determine excessive leakage?  Besides, doesn't the anemometer measure just velocity (fpm) not volume of air (cfm) unless you know the ft2 area of the…"
Sep 27, 2012
Bob Kretvix replied to Dmitri A Martin's discussion Spray Foam Liability
"You are right about the significant cost for air sampling.  As an Industrial Hygienist, that is primarily what I do for a living (in addition to home performance audits) - we are the experts in indoor air quality and chemical exposure…"
Feb 9, 2012
Bob Kretvix replied to Ti Mougne's discussion Dirty Sock Syndrome in high efficiency HVAC units
"Dirty Sock Syndrome is actually caused by a combination of bacterial "slime" (biofilm) and mold, such as yeasts, that typically grow on the coils of the unit.  The biofilm has been described as being like the slippery, slimy surface…"
Feb 2, 2012
Bob Kretvix replied to Dmitri A Martin's discussion Ambient Combustable Gas
"Dmitri Gas leak detectors are generalized meters which can detect a wide variety of combustible vapors, not just natural gas and propane. Alcohols, gasoline, paint solvents, nail polish remover, aerosol propellants (e.g., butane) are examples. …"
Dec 29, 2011
Bob Kretvix commented on Mike Majors's video
Thumbnail

Conserve101 - Swimming Pool Energy Savings Tips

"I should also mention that the video showed a sand filter.  My experience as a pool owner for the last 50 yrs (since I was 7 yrs old) is that the sand filters have to be run much longer.  And in many cases they don't ever get the…"
Jun 23, 2011
Bob Kretvix commented on Mike Majors's video
Thumbnail

Conserve101 - Swimming Pool Energy Savings Tips

"Mike - Good video.  But also be aware of some new technology out this year that can decrease pool pump energy costs dramatically.  Hayward and Pentair just introduced new high efficiency pumps this season. Rather than running full out all…"
Jun 23, 2011
Bob Kretvix replied to Evan Mills's discussion How's the water? Managing energy use in Pools.
"Tom, Why did you have to change the plumbing in the San Diego pool?  I just purchased a Hayward Ecostar that essentially does the same thing as the Pentair for an existing pool without any noticeable problems. But you are right - these new…"
Jun 2, 2011
Jon LaMonte replied to Bob Kretvix's discussion Is It Conflict of Interest for BPI Energy Auditors To Sell Weatherization Products and Home Improvements? in the group Building Performance Institute (BPI)
"I have to agree with your last comment the most. What we are doing is what more people in our industry SHOULD be doing. Simply talking."
Apr 9, 2011
Jon LaMonte replied to Bob Kretvix's discussion Is It Conflict of Interest for BPI Energy Auditors To Sell Weatherization Products and Home Improvements? in the group Building Performance Institute (BPI)
"We have the Home Performance w/ Energy Star program here through Georgia Power. The program has a specific protocol and the reports give an ABCD priority to the findings of the audit. The only problem with the program is that the homeowner must…"
Apr 9, 2011
Bob Kretvix replied to Bob Kretvix's discussion Is It Conflict of Interest for BPI Energy Auditors To Sell Weatherization Products and Home Improvements? in the group Building Performance Institute (BPI)
"Thanks Tom.  I'll take a look.  However, I just purchased a home inspection software, Home Gauge, which also has good reviews from a variety of places. I loaded with all my pre-written energy audit recommendations rather than using…"
Apr 9, 2011
Tom Lewis replied to Bob Kretvix's discussion Is It Conflict of Interest for BPI Energy Auditors To Sell Weatherization Products and Home Improvements? in the group Building Performance Institute (BPI)
"On the flip side of the coin, Bob, one could easily say that there are as many or MORE non-auditor contractors who will scam the customer. So the argument might be that the best judge for the best measures with the best ROI could in fact be the…"
Apr 9, 2011

Profile Information

Company
EHS Innovators LLC
Professional Certification
BPI Building Analyst/Envelope Professional, Certified Industrial Hygienist (CIH), Certified Building Science Thermographer (CBST), Certified Environmental Trainer (CET)
Professional Interests
Resolving indoor air quality, moisture/mold and energy conservation issues using a holistic building science approach.
Website URL
http://www.ehsi.com
LinkedIn Profile
Bob Kretvix, CIH, CET, CBST

Comment Wall

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

  • No comments yet!
 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Joe Konopacki posted an event

Duct & Envelope Tightness (DET) Verifier at Temperature Equipment Corporation

May 8, 2015 from 8:30am to 4:30pm
The Duct & Envelope Tightness Certification (DET) was designed by the Illinois Association of…See More
6 hours ago
Paul Raymer posted a blog post

Shades of Gray in Residential Construction Morality

I was called in to perform a last minute duct test for a modular home builder.  He was all in a…See More
8 hours ago
Alfie Davis posted a blog post

Tiles Flooring – A Better Choice than Concrete Flooring

This article can change one’s perception about flooring and can act as an excellent guide in…See More
10 hours ago
Charlie Hewitt posted a blog post

Residential Electric Load Disaggregation

“What gets measured gets managed” is a quote often attributed to the venerable management expert…See More
22 hours ago
Kurt Albershardt replied to Larry Schaffert's discussion How to correctly insulate exterior wall in a 1900 house?
"Balloon framed houses make for easy upgrades IME.  We cover the open bays from the sill plate…"
22 hours ago
Kurt Albershardt replied to William Fisher's discussion Can tankless water heaters provide hot water even when the groundwater is fairly cold?
"There are a number of approaches that can work depending on the specifics of your situation. What…"
22 hours ago
Bob Mariani joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
yesterday
Bob Mariani replied to William Parlapiano's discussion Equipment for Sale Updated April 9, 2015 in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"I would be interested in a package deal for the items marked as "Available"  Email…"
yesterday

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service