ZPD House

Targeted airsealing, series leakage testing, duct balancing, and blower door testing can be performed. The ZPD House can be projected onto a screen for larger audiences.

Views: 268

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Dale@EnergyWright on March 1, 2011 at 7:22pm
Thanks, Jack and Michael. That was the idea behind designing it.  Most of the folks we train are kinesthetic learners, they see a problem and go hands-on to fix the problem.  Pressure diagnostics is a little different, it requires folks to build a mental framework of a particular building's interactive pressures, determine the issues and solutions, fix it, then confirm it was corrected properly.  Not an easy task when much of the reconstruction work happens in your head.  We expect this pressure diagnostics simulator will provide the intuitive mental exercises needed to make for effective auditors and technicians in the field.
Comment by Jack Baikoff on March 1, 2011 at 4:00pm
This looks like a wonderful educational tool
Comment by Michael Dunseith on February 19, 2011 at 2:15pm
AWESOME Dale

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

George Matthews replied to George Matthews's discussion Shortridge 8400 Flowhood for A/C airflow testing in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Here are the pics of the flowhood and airdata manometer"
yesterday
Sarah Holloway posted a photo
yesterday
Joe Urycki added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

TEC blower door and UEI combustion analyzer for sale

For sale is one used TEC Minneapolis blower door system: Includes model 3 fan with rings A and B,…See More
yesterday
John Nicholas replied to Kevin Emerson's discussion Studies re: radon mitigation and energy efficiency
"The Nay side is well represented with the links already posted. I presented a neutral side, with…"
Friday
Ray Lehman replied to Kevin Emerson's discussion Studies re: radon mitigation and energy efficiency
"Hey John, Thanks for the information.  Very good empirical data. While I agree that running…"
Friday
John Nicholas replied to Kevin Emerson's discussion Studies re: radon mitigation and energy efficiency
"I have no links, just some anecdotal evidence. I had several Blower Door Tests done on my own home.…"
Friday
Chris Laumer-Giddens commented on Chris Laumer-Giddens's blog post Raising the BARrier in North Carolina Mountain Home, Air Tight Ceiling
"@Joe Nagan, We have found this technique to be WAY simpler and A LOT less labor than making a…"
Thursday
Judy Rachel replied to Blake Shurtz's discussion Testing spillage on induced draft furnace?
"I hope the attached picture is clear enough for you to see.  As the caption on the picture…"
Thursday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by