Comment by Eric Kjelshus on July 15, 2014 at 6:44am

I took 3 HOBO's and put in flue gas B1 pipe very top - mid way - at breaching ( in basement)  with a over sized 80% my house before change out but after sealing and high R was done, when from R-13 attic to R49 and sealed all holes walls from r-6 to R-20 and sealed with new windows.  went from 97,000 BTU to 34,000 BTUs/hr at 0'  I took the stat at 1' droop  and put a 5 gal bucket  under the hoz run.  At top of flue pipe never got to 250' and stayed  wet the whole time.  I rotted the flue/furnace/ in 4 mo.   You have to dry out the flue each hour to keep the pipe from just coming apart and fall down.  If you keep flue gas ( in my case) above 265'  with both hot water heater and furnace  above 265' will dry out the flue and will last very very long time.  I do my best to keep the flue gas temp as high as I can, Its the heat that's keeps the flue gas up the flue and out of the building,  unless you use a power vent  or PVC flue pipe.   

Comment by Bob Blanchette on July 14, 2014 at 7:40pm

+1 if flue gasses are too cool it will simply rot the pipe out. That's a big reason that double wall pipe (b vent) is used even when it's not required by code for low clearance.

Comment by Eric Kjelshus on May 28, 2014 at 7:07pm

I saw this a lot in the 60-70'.   not so much with 95% furnaces.   This will drop the flue temp some 100'  then the flue will condensate - stays wet then it just rots  outside in.   For fun turn the stat up to 85'  then use the IR photo to see heat loss.    Then look at temp at top of flue if under dew point then drip.  This will just rot the boiler/furnace/hot water and flue pipe

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Bret Curry replied to Hal Skinner's discussion An example of what an RCC can do with no R- insulation in the walls.
"What is the emissivity of the RCC used on this project? Thanks "
4 minutes ago
Elizabeth Coe joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
6 minutes ago
Steven Lewis replied to George Kopf's discussion Extremely long wait for hot water
"There is a pump kit that will install under a sink or in a bathroom.  This pump will be…"
54 minutes ago
Steven Lewis replied to Aaren Stewart's discussion Let's solve this HVAC quiz!!!
"answer ! - It is a dungeon Answer 2 - it has been placed on part time work so it has lost its…"
59 minutes ago
Matt Bolado posted a discussion

Plenum Pressure Match

I'm seeking an explanation on how to do a plenum pressure match using the Retrotec Duct Blaster.…See More
1 hour ago
Kim Tanner replied to Trip Smith's discussion Where to spend my marketing dollars?
"Hi Trip It's based off my experience here, at The Energy Conservatory (yes, we make the…"
1 hour ago
Casey Gesell posted a status
1 hour ago
Craig Foley replied to George Kopf's discussion Real Estate Professionals need our support - but how?
"Thanks for the shoutout George. MA DOER worked with my company on an initiative to educate real…"
2 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service