WT*

You tell me?

Views: 244

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Jennifer Stutzman on July 1, 2015 at 6:46am

Beer can radiator?

Comment by Chris Petroskas on October 2, 2014 at 8:53am

Sure, it is terrible for the pipe and the heating system in general BUT, it does look pretty cool!

Comment by Eric Kjelshus on July 15, 2014 at 6:44am

I took 3 HOBO's and put in flue gas B1 pipe very top - mid way - at breaching ( in basement)  with a over sized 80% my house before change out but after sealing and high R was done, when from R-13 attic to R49 and sealed all holes walls from r-6 to R-20 and sealed with new windows.  went from 97,000 BTU to 34,000 BTUs/hr at 0'  I took the stat at 1' droop  and put a 5 gal bucket  under the hoz run.  At top of flue pipe never got to 250' and stayed  wet the whole time.  I rotted the flue/furnace/ in 4 mo.   You have to dry out the flue each hour to keep the pipe from just coming apart and fall down.  If you keep flue gas ( in my case) above 265'  with both hot water heater and furnace  above 265' will dry out the flue and will last very very long time.  I do my best to keep the flue gas temp as high as I can, Its the heat that's keeps the flue gas up the flue and out of the building,  unless you use a power vent  or PVC flue pipe.   

Comment by Bob Blanchette on July 14, 2014 at 7:40pm

+1 if flue gasses are too cool it will simply rot the pipe out. That's a big reason that double wall pipe (b vent) is used even when it's not required by code for low clearance.

Comment by Eric Kjelshus on May 28, 2014 at 7:07pm

I saw this a lot in the 60-70'.   not so much with 95% furnaces.   This will drop the flue temp some 100'  then the flue will condensate - stays wet then it just rots  outside in.   For fun turn the stat up to 85'  then use the IR photo to see heat loss.    Then look at temp at top of flue if under dew point then drip.  This will just rot the boiler/furnace/hot water and flue pipe

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Seth Romme commented on Home Energy Magazine's blog post Natural Gas is Becoming Less Attractive
"Thanks for the post! While true from the clean & environmental side, we (eFree Advisors)…"
1 hour ago
David Ware added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

Weatherization and Testing Equipment for sale - Wisconsin

2000 Chev. W-4500 Tiltmaster Truck           Outfitted with shelving specific to insulation…See More
2 hours ago
David Ware joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
3 hours ago
Kobus Niemand commented on Alfie Davis's blog post Ways to Give Your Kitchen a Beautiful Makeover
"I got some new black and white granite tops to replace the old laminated stuff. They really change…"
5 hours ago
Kobus Niemand commented on Home Energy Magazine's blog post Natural Gas is Becoming Less Attractive
"Well after the greatest natural disaster in human history, who can blame…"
5 hours ago
Kobus Niemand commented on Alfie Davis's blog post Chic New Trends in Kitchen Renovation
"Nice tips! Thanks for the recommendations! With tiles for the kitchen, do you go with dark or light…"
5 hours ago
Alfie Davis posted a blog post
10 hours ago
Profile IconAlfonso Scott, Susan Benford, HomeWiz and 2 more joined Home Energy Pros
23 hours ago

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service