Comment by Jennifer Stutzman on July 1, 2015 at 6:46am

Beer can radiator?

Comment by Chris Petroskas on October 2, 2014 at 8:53am

Sure, it is terrible for the pipe and the heating system in general BUT, it does look pretty cool!

Comment by Eric Kjelshus on July 15, 2014 at 6:44am

I took 3 HOBO's and put in flue gas B1 pipe very top - mid way - at breaching ( in basement)  with a over sized 80% my house before change out but after sealing and high R was done, when from R-13 attic to R49 and sealed all holes walls from r-6 to R-20 and sealed with new windows.  went from 97,000 BTU to 34,000 BTUs/hr at 0'  I took the stat at 1' droop  and put a 5 gal bucket  under the hoz run.  At top of flue pipe never got to 250' and stayed  wet the whole time.  I rotted the flue/furnace/ in 4 mo.   You have to dry out the flue each hour to keep the pipe from just coming apart and fall down.  If you keep flue gas ( in my case) above 265'  with both hot water heater and furnace  above 265' will dry out the flue and will last very very long time.  I do my best to keep the flue gas temp as high as I can, Its the heat that's keeps the flue gas up the flue and out of the building,  unless you use a power vent  or PVC flue pipe.   

Comment by Bob Blanchette on July 14, 2014 at 7:40pm

+1 if flue gasses are too cool it will simply rot the pipe out. That's a big reason that double wall pipe (b vent) is used even when it's not required by code for low clearance.

Comment by Eric Kjelshus on May 28, 2014 at 7:07pm

I saw this a lot in the 60-70'.   not so much with 95% furnaces.   This will drop the flue temp some 100'  then the flue will condensate - stays wet then it just rots  outside in.   For fun turn the stat up to 85'  then use the IR photo to see heat loss.    Then look at temp at top of flue if under dew point then drip.  This will just rot the boiler/furnace/hot water and flue pipe

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

George Matthews commented on George Matthews's event Proof is Possible Tour by the Home Performance Workshop
"Here is the flyer for the Advanced Techniques and Tools in Home Performance Friday October 7th at…"
2 hours ago
George Matthews posted an event

Proof is Possible Tour by the Home Performance Workshop at Truitt and White Lumber Conference Room

October 7, 2016 from 9am to 1pm
Building Energy Performance Testing is sponsoring the Proof is Possible Tour to come to the San…See More
3 hours ago
George Matthews replied to George Matthews's discussion Shortridge 8400 Flowhood for A/C airflow testing in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Here are the pics of the flowhood and airdata manometer"
Saturday
Sarah Holloway posted a photo
Friday
Joe Urycki added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

TEC blower door and UEI combustion analyzer for sale

For sale is one used TEC Minneapolis blower door system: Includes model 3 fan with rings A and B,…See More
Friday
John Nicholas replied to Kevin Emerson's discussion Studies re: radon mitigation and energy efficiency
"The Nay side is well represented with the links already posted. I presented a neutral side, with…"
Friday
Ray Lehman replied to Kevin Emerson's discussion Studies re: radon mitigation and energy efficiency
"Hey John, Thanks for the information.  Very good empirical data. While I agree that running…"
Friday
John Nicholas replied to Kevin Emerson's discussion Studies re: radon mitigation and energy efficiency
"I have no links, just some anecdotal evidence. I had several Blower Door Tests done on my own home.…"
Friday