Comment by Jennifer Stutzman on July 1, 2015 at 6:46am

Beer can radiator?

Comment by Chris Petroskas on October 2, 2014 at 8:53am

Sure, it is terrible for the pipe and the heating system in general BUT, it does look pretty cool!

Comment by Eric Kjelshus on July 15, 2014 at 6:44am

I took 3 HOBO's and put in flue gas B1 pipe very top - mid way - at breaching ( in basement)  with a over sized 80% my house before change out but after sealing and high R was done, when from R-13 attic to R49 and sealed all holes walls from r-6 to R-20 and sealed with new windows.  went from 97,000 BTU to 34,000 BTUs/hr at 0'  I took the stat at 1' droop  and put a 5 gal bucket  under the hoz run.  At top of flue pipe never got to 250' and stayed  wet the whole time.  I rotted the flue/furnace/ in 4 mo.   You have to dry out the flue each hour to keep the pipe from just coming apart and fall down.  If you keep flue gas ( in my case) above 265'  with both hot water heater and furnace  above 265' will dry out the flue and will last very very long time.  I do my best to keep the flue gas temp as high as I can, Its the heat that's keeps the flue gas up the flue and out of the building,  unless you use a power vent  or PVC flue pipe.   

Comment by Bob Blanchette on July 14, 2014 at 7:40pm

+1 if flue gasses are too cool it will simply rot the pipe out. That's a big reason that double wall pipe (b vent) is used even when it's not required by code for low clearance.

Comment by Eric Kjelshus on May 28, 2014 at 7:07pm

I saw this a lot in the 60-70'.   not so much with 95% furnaces.   This will drop the flue temp some 100'  then the flue will condensate - stays wet then it just rots  outside in.   For fun turn the stat up to 85'  then use the IR photo to see heat loss.    Then look at temp at top of flue if under dew point then drip.  This will just rot the boiler/furnace/hot water and flue pipe

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Empower Efficiency added a discussion to the group Job Board
Thumbnail

Position Opening: Local Community Outreach Specialist, Energy Efficiency (San Carlos, CA)

Local Community Outreach Specialist, Energy Efficiency (San Carlos, CA) Job Title: Local Community…See More
16 hours ago
Amber Vignieri posted a blog post

Elevate Energy Mythbusters: Windows & Attics Edition

This blog post is guest written by former staff member Eric Keeley.Great enthusiasm for home energy…See More
17 hours ago
Glen Gallo replied to Diane Chojnowski's discussion Poll: What is you favorite or most important home performance diagnostic or measurement tool?
"I agree with Ted. If I could bring just one piece of equipment it would be the blower door. It has…"
20 hours ago
Glen Gallo replied to Shaun 's discussion Commercial duct testing
"If above the ceiling tiles the wall is a finished assembly and there is insulation on or under the…"
20 hours ago
Tom White's video was featured

Combustion Appliance Zone Testing (CAZ) Made Easy (March 24, 2016)

Combustion Appliance Zone Testing (CAZ) Made Easy (March 24, 2016) -Gauge Fundamentals -Adapting to the new BPI standard -RESNET testing requirements -NFPA testing requirements -Best practices for best results
20 hours ago
Profile IconLaura Capps and Bret Abrams joined Home Energy Pros
yesterday
Olivia Taylor posted a blog post

5 Key Reasons Why Rooftop Solar Is Popular In The US

The rapid switch from traditional electricity to clean, economical and renewable solar energy is…See More
Thursday
Adam Swain posted a blog post

Top 5 Tips For Hiring A Crawl Space Contractor

A homes crawl space is one of the few places most homeowners try to avoid at all cost, and for good…See More
Wednesday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service