Comment by Jennifer Stutzman on July 1, 2015 at 6:46am

Beer can radiator?

Comment by Chris Petroskas on October 2, 2014 at 8:53am

Sure, it is terrible for the pipe and the heating system in general BUT, it does look pretty cool!

Comment by Eric Kjelshus on July 15, 2014 at 6:44am

I took 3 HOBO's and put in flue gas B1 pipe very top - mid way - at breaching ( in basement)  with a over sized 80% my house before change out but after sealing and high R was done, when from R-13 attic to R49 and sealed all holes walls from r-6 to R-20 and sealed with new windows.  went from 97,000 BTU to 34,000 BTUs/hr at 0'  I took the stat at 1' droop  and put a 5 gal bucket  under the hoz run.  At top of flue pipe never got to 250' and stayed  wet the whole time.  I rotted the flue/furnace/ in 4 mo.   You have to dry out the flue each hour to keep the pipe from just coming apart and fall down.  If you keep flue gas ( in my case) above 265'  with both hot water heater and furnace  above 265' will dry out the flue and will last very very long time.  I do my best to keep the flue gas temp as high as I can, Its the heat that's keeps the flue gas up the flue and out of the building,  unless you use a power vent  or PVC flue pipe.   

Comment by Bob Blanchette on July 14, 2014 at 7:40pm

+1 if flue gasses are too cool it will simply rot the pipe out. That's a big reason that double wall pipe (b vent) is used even when it's not required by code for low clearance.

Comment by Eric Kjelshus on May 28, 2014 at 7:07pm

I saw this a lot in the 60-70'.   not so much with 95% furnaces.   This will drop the flue temp some 100'  then the flue will condensate - stays wet then it just rots  outside in.   For fun turn the stat up to 85'  then use the IR photo to see heat loss.    Then look at temp at top of flue if under dew point then drip.  This will just rot the boiler/furnace/hot water and flue pipe

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Paul Raymer posted an event
Thumbnail

MA Crew Chief/BPI Building Analyst Training at Bristol Community College at Commonwealth Landing

September 12, 2016 at 9am to September 16, 2016 at 4:30pm
Bristol Community College has created a hands-on training cabin in their laboratory.  This class…See More
3 hours ago
Daniel Morrison replied to John Nicholas's discussion Slab Edge Insulation - A Side Thread to Melissa's Question
"John, I just collaborated with Steve Baczek on a few videos for ProTradeCraft about slab insulation…"
11 hours ago
Profile IconMichael Sumpter and Bill Gartner joined Home Energy Pros
yesterday
Malcolm Jackson joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
yesterday
Amber Vignieri liked tedkidd's discussion What if more efficient homes were actually worth more?
yesterday
Amber Vignieri posted a blog post
yesterday
Eric Kjelshus replied to Rob Madden, Solar Home Broker's discussion Indoor Air Quality Monitors and Meters
"I have been using air advice for 5 yr or so - I end up with a report in 35 min I can e-mail or show…"
yesterday
Profile IconShane Matteson, Jay Cooper and Mike Harris joined Home Energy Pros
Thursday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service