WT*

You tell me?

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Eric Kjelshus on July 15, 2014 at 6:44am

I took 3 HOBO's and put in flue gas B1 pipe very top - mid way - at breaching ( in basement)  with a over sized 80% my house before change out but after sealing and high R was done, when from R-13 attic to R49 and sealed all holes walls from r-6 to R-20 and sealed with new windows.  went from 97,000 BTU to 34,000 BTUs/hr at 0'  I took the stat at 1' droop  and put a 5 gal bucket  under the hoz run.  At top of flue pipe never got to 250' and stayed  wet the whole time.  I rotted the flue/furnace/ in 4 mo.   You have to dry out the flue each hour to keep the pipe from just coming apart and fall down.  If you keep flue gas ( in my case) above 265'  with both hot water heater and furnace  above 265' will dry out the flue and will last very very long time.  I do my best to keep the flue gas temp as high as I can, Its the heat that's keeps the flue gas up the flue and out of the building,  unless you use a power vent  or PVC flue pipe.   

Comment by Bob Blanchette on July 14, 2014 at 7:40pm

+1 if flue gasses are too cool it will simply rot the pipe out. That's a big reason that double wall pipe (b vent) is used even when it's not required by code for low clearance.

Comment by Eric Kjelshus on May 28, 2014 at 7:07pm

I saw this a lot in the 60-70'.   not so much with 95% furnaces.   This will drop the flue temp some 100'  then the flue will condensate - stays wet then it just rots  outside in.   For fun turn the stat up to 85'  then use the IR photo to see heat loss.    Then look at temp at top of flue if under dew point then drip.  This will just rot the boiler/furnace/hot water and flue pipe

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Profile IconKevin Jordan, Hannah Strong, Rich Snyder and 1 more joined Home Energy Pros
1 hour ago
EnergyLogic Academy posted events
1 hour ago
EnergyLogic Academy updated an event
Thumbnail

RESCAZ- RESNET Combustion Safety Testing: North Carolina at Wilmington, NC

November 7, 2014 from 6pm to 7pm
The health and safety of the home energy auditor’s clients should be the top priority when…See More
2 hours ago
EnergyLogic Academy updated an event
Thumbnail

RESNET Phase 2 Rater Training - Field Training at EnergyLogic Academy - Berthoud CO

September 22, 2014 to September 24, 2014
The EnergyLogic Academy will be hosting the second phase of HERS Rater Training August 4th - 7th,…See More
2 hours ago
Hal Skinner replied to Scott Katznelson's discussion Database of zip code or county by climate zone
"Hi Scott. I dont know of a database that you are referring to.  I was always under the…"
2 hours ago
Rich Snyder joined Rich Brunco's group
Thumbnail

Cape Cod Energy Pros

Recent BPI classmates, a place to share referals and informationSee More
3 hours ago
Scott Katznelson posted a discussion

Database of zip code or county by climate zone

HI.  I'm looking for a database that could help me assess the average energy use of a home (per…See More
9 hours ago
Hal Skinner replied to Hal Skinner's discussion The 'Touchy - Feely' sales pitch. in the group Radiant Control Coatings
"The 2nd bestsales tool I ever came up with.  aI will be happy to send anyone a test strip like…"
16 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service