Comment by Chris Petroskas on October 2, 2014 at 8:53am

Sure, it is terrible for the pipe and the heating system in general BUT, it does look pretty cool!

Comment by Eric Kjelshus on July 15, 2014 at 6:44am

I took 3 HOBO's and put in flue gas B1 pipe very top - mid way - at breaching ( in basement)  with a over sized 80% my house before change out but after sealing and high R was done, when from R-13 attic to R49 and sealed all holes walls from r-6 to R-20 and sealed with new windows.  went from 97,000 BTU to 34,000 BTUs/hr at 0'  I took the stat at 1' droop  and put a 5 gal bucket  under the hoz run.  At top of flue pipe never got to 250' and stayed  wet the whole time.  I rotted the flue/furnace/ in 4 mo.   You have to dry out the flue each hour to keep the pipe from just coming apart and fall down.  If you keep flue gas ( in my case) above 265'  with both hot water heater and furnace  above 265' will dry out the flue and will last very very long time.  I do my best to keep the flue gas temp as high as I can, Its the heat that's keeps the flue gas up the flue and out of the building,  unless you use a power vent  or PVC flue pipe.   

Comment by Bob Blanchette on July 14, 2014 at 7:40pm

+1 if flue gasses are too cool it will simply rot the pipe out. That's a big reason that double wall pipe (b vent) is used even when it's not required by code for low clearance.

Comment by Eric Kjelshus on May 28, 2014 at 7:07pm

I saw this a lot in the 60-70'.   not so much with 95% furnaces.   This will drop the flue temp some 100'  then the flue will condensate - stays wet then it just rots  outside in.   For fun turn the stat up to 85'  then use the IR photo to see heat loss.    Then look at temp at top of flue if under dew point then drip.  This will just rot the boiler/furnace/hot water and flue pipe

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Hannah Finch posted a blog post
4 hours ago
Hannah Finch updated an event
Thumbnail

RaterFest! 2015 - Mark LaLiberte Keynote at Estes Park

September 18, 2015 at 3pm to September 20, 2015 at 3pm
RaterFest! is EnergyLogic’s  incredible two and a half day training conference nestled amongst the…See More
4 hours ago
Kerry posted videos
5 hours ago
John Meniatis posted videos
5 hours ago
Steve Schmidt joined Sean Lintow Sr's group
Thumbnail

Best Practices (Residential)

Best Building, Retrofitting, or even Auditing Practices - what are they, what should change, what…See More
5 hours ago
Profile IconDonna Lynn Saufley, John J Gilchrist, Steve Schmidt and 2 more joined Home Energy Pros
6 hours ago
Jerry Lawrence posted an event
Thumbnail

BPI Building Analyst Certification Workshop at ThermalStar

April 20, 2015 at 8am to April 24, 2015 at 5pm
The BPI Building Analyst Certification class is the most convenient way to get certified by BPI and…See More
6 hours ago
Hal Skinner replied to Hal Skinner's discussion 'YGRENE' super fund for energy upgrade financing
"I think it would be best to keep the questions and answers on this open forum for all to see. Cali…"
8 hours ago

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service