WT*

You tell me?

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Eric Kjelshus on July 15, 2014 at 6:44am

I took 3 HOBO's and put in flue gas B1 pipe very top - mid way - at breaching ( in basement)  with a over sized 80% my house before change out but after sealing and high R was done, when from R-13 attic to R49 and sealed all holes walls from r-6 to R-20 and sealed with new windows.  went from 97,000 BTU to 34,000 BTUs/hr at 0'  I took the stat at 1' droop  and put a 5 gal bucket  under the hoz run.  At top of flue pipe never got to 250' and stayed  wet the whole time.  I rotted the flue/furnace/ in 4 mo.   You have to dry out the flue each hour to keep the pipe from just coming apart and fall down.  If you keep flue gas ( in my case) above 265'  with both hot water heater and furnace  above 265' will dry out the flue and will last very very long time.  I do my best to keep the flue gas temp as high as I can, Its the heat that's keeps the flue gas up the flue and out of the building,  unless you use a power vent  or PVC flue pipe.   

Comment by Bob Blanchette on July 14, 2014 at 7:40pm

+1 if flue gasses are too cool it will simply rot the pipe out. That's a big reason that double wall pipe (b vent) is used even when it's not required by code for low clearance.

Comment by Eric Kjelshus on May 28, 2014 at 7:07pm

I saw this a lot in the 60-70'.   not so much with 95% furnaces.   This will drop the flue temp some 100'  then the flue will condensate - stays wet then it just rots  outside in.   For fun turn the stat up to 85'  then use the IR photo to see heat loss.    Then look at temp at top of flue if under dew point then drip.  This will just rot the boiler/furnace/hot water and flue pipe

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Chris Laumer-Giddens posted a blog post

Mini-Split Heat Pumps are Quirky, Especially their Capacity

Mini-Split Heat Pumps are Quirky and Still EffectiveThe name "mini-splits" generally refers to heat…See More
7 hours ago
Jan Green posted an event

Solar Course for Appraisers at SRP's Pera Club

November 13, 2014 to November 14, 2014
"As the US continues to search for energy alternatives, properties improved with solar PV…See More
7 hours ago
Hal Skinner replied to Hal Skinner's discussion What an RCC can do with no R- insulation in the walls.
"Just like paint.  RFoller and brush or strong airless sprayer.  It has the consistency of…"
11 hours ago
Hal Skinner replied to Hal Skinner's discussion What an RCC can do with no R- insulation in the walls.
"ty and thermal emission leveld of many materials including bricks and white paint.  They do…"
11 hours ago
Hal Skinner added a discussion to the group The RCC Classroom (Radiant Control Coatings)
Thumbnail

Walmart goes green in Texas

We applied cour RCC to 5 Walmart superstores in Texas.  Worked great and they wanted it.  Then they…See More
11 hours ago
Kim Tanner replied to Trip Smith's discussion Where to spend my marketing dollars?
"Direct mail doesn't do very much, in my opinion, unless you have awesome coupons! Honestly,…"
12 hours ago
Hal Skinner replied to Hal Skinner's discussion What an RCC can do with no R- insulation in the walls.
"Mornn Trip and Bud, In this case all I can do is report it exactly as it was told to me.  I…"
12 hours ago
Bud Poll replied to Hal Skinner's discussion What an RCC can do with no R- insulation in the walls.
"Hi Hal, I have no experience with your RCC product, but I can comment in regards to using a radiant…"
15 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service