Comment by Chris Petroskas on October 2, 2014 at 8:53am

Sure, it is terrible for the pipe and the heating system in general BUT, it does look pretty cool!

Comment by Eric Kjelshus on July 15, 2014 at 6:44am

I took 3 HOBO's and put in flue gas B1 pipe very top - mid way - at breaching ( in basement)  with a over sized 80% my house before change out but after sealing and high R was done, when from R-13 attic to R49 and sealed all holes walls from r-6 to R-20 and sealed with new windows.  went from 97,000 BTU to 34,000 BTUs/hr at 0'  I took the stat at 1' droop  and put a 5 gal bucket  under the hoz run.  At top of flue pipe never got to 250' and stayed  wet the whole time.  I rotted the flue/furnace/ in 4 mo.   You have to dry out the flue each hour to keep the pipe from just coming apart and fall down.  If you keep flue gas ( in my case) above 265'  with both hot water heater and furnace  above 265' will dry out the flue and will last very very long time.  I do my best to keep the flue gas temp as high as I can, Its the heat that's keeps the flue gas up the flue and out of the building,  unless you use a power vent  or PVC flue pipe.   

Comment by Bob Blanchette on July 14, 2014 at 7:40pm

+1 if flue gasses are too cool it will simply rot the pipe out. That's a big reason that double wall pipe (b vent) is used even when it's not required by code for low clearance.

Comment by Eric Kjelshus on May 28, 2014 at 7:07pm

I saw this a lot in the 60-70'.   not so much with 95% furnaces.   This will drop the flue temp some 100'  then the flue will condensate - stays wet then it just rots  outside in.   For fun turn the stat up to 85'  then use the IR photo to see heat loss.    Then look at temp at top of flue if under dew point then drip.  This will just rot the boiler/furnace/hot water and flue pipe

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Richard Beyer posted a discussion

Media Reports Spray Polyurethane Foam Insulation spontaneously combusted a $5M Connecticut Home... "The Conclusion"

OFFICE OF THE FIRE MARSHAL1212 WHITTEMORE RDMIDDLEBURY, CONNECTICUT Fire Investigation Report –…See More
6 hours ago
Profile IconDavid Hepinstall and Matthew joined Home Energy Pros
12 hours ago
Steve Leombruno posted a blog post

Static power energy box

Just wondering if You've heard of this Static power energy box that boasts energy consumption…See More
16 hours ago
Bud Poll replied to Sean Lintow Sr's discussion Blower Doors & Methods Used in the group Best Practices (Residential)
"Hi Sean, I have a question for you.  If you were only interested in providing the best audit…"
19 hours ago
Martin Geib posted an event
Thumbnail

WUFI Pro Training at 475 Headquarters

March 13, 2015 from 9am to 5pm
475 is proud to partner with WUFI Pro developer, Manfred Kehrer, for this training. Manfred…See More
yesterday
Tom White posted videos
yesterday
Michael Knezovich's event was featured

10th Annual North American Passive House Conference at Hyatt Regency Chicago

September 9, 2015 to September 13, 2015
The largest, longest running passive house focused even in North America. Presented by Passive…See More
yesterday
Tom White's video was featured

Adrian Camilleri on Choice Architecture and Translated Attributes

Dr. Adrian Camilleri (http://adriancamilleri.net/) discusses the concept of "choice architecture". Use it to improve your home performance sales strategies!
yesterday

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service