Comment by Chris Petroskas on October 2, 2014 at 8:53am

Sure, it is terrible for the pipe and the heating system in general BUT, it does look pretty cool!

Comment by Eric Kjelshus on July 15, 2014 at 6:44am

I took 3 HOBO's and put in flue gas B1 pipe very top - mid way - at breaching ( in basement)  with a over sized 80% my house before change out but after sealing and high R was done, when from R-13 attic to R49 and sealed all holes walls from r-6 to R-20 and sealed with new windows.  went from 97,000 BTU to 34,000 BTUs/hr at 0'  I took the stat at 1' droop  and put a 5 gal bucket  under the hoz run.  At top of flue pipe never got to 250' and stayed  wet the whole time.  I rotted the flue/furnace/ in 4 mo.   You have to dry out the flue each hour to keep the pipe from just coming apart and fall down.  If you keep flue gas ( in my case) above 265'  with both hot water heater and furnace  above 265' will dry out the flue and will last very very long time.  I do my best to keep the flue gas temp as high as I can, Its the heat that's keeps the flue gas up the flue and out of the building,  unless you use a power vent  or PVC flue pipe.   

Comment by Bob Blanchette on July 14, 2014 at 7:40pm

+1 if flue gasses are too cool it will simply rot the pipe out. That's a big reason that double wall pipe (b vent) is used even when it's not required by code for low clearance.

Comment by Eric Kjelshus on May 28, 2014 at 7:07pm

I saw this a lot in the 60-70'.   not so much with 95% furnaces.   This will drop the flue temp some 100'  then the flue will condensate - stays wet then it just rots  outside in.   For fun turn the stat up to 85'  then use the IR photo to see heat loss.    Then look at temp at top of flue if under dew point then drip.  This will just rot the boiler/furnace/hot water and flue pipe

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Rick Karg replied to Carly@AirCycler's discussion The (Small) Cost of Ventilation Without Recovery
"As a member of the ASHRAE 62.2 committee (and president of Residential Energy Dynamics, the author…"
Friday
Bradford E. White replied to Elizabeth Guinn's discussion ERV in need of backflow preventer.
"I would use an in-line backdraft damper such as Artis Industries or the ones made by Fantech and…"
Thursday
Kim Tanner posted a video

Wireless Air Leakage Testing

This webinar will discuss the use of WiFi technology to conduct and document blower door and duct leakage tests for compliance with local energy codes. The s...
Thursday
Profile IconPerry Grossman, Daniel Pate and Ottawa Furnace Filters joined Home Energy Pros
Thursday
Kirsten Richnavsky added a discussion to the group Building Performance Institute (BPI)
Thumbnail

Breaking the link between unhealthy homes and unhealthy kids

Listen in on IAQ Radio to a discussion on reducing the household triggers that cause asthmaattacks…See More
Thursday
Kirsten Richnavsky posted a discussion

Breaking the link between unhealthy homes and unhealthy kids

Listen in on IAQ Radio to a discussion on reducing the household triggers that cause asthmaattacks…See More
Thursday
Kim Tanner posted events
Thursday
Ottawa Furnace Filters posted a blog post

Some Useful Information about Furnace Air Filters

There is not much we can do about the air pollution outside of a house in Ottawa, Canada, but we…See More
Thursday

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service