Comment by Eric Kjelshus on July 15, 2014 at 6:44am

I took 3 HOBO's and put in flue gas B1 pipe very top - mid way - at breaching ( in basement)  with a over sized 80% my house before change out but after sealing and high R was done, when from R-13 attic to R49 and sealed all holes walls from r-6 to R-20 and sealed with new windows.  went from 97,000 BTU to 34,000 BTUs/hr at 0'  I took the stat at 1' droop  and put a 5 gal bucket  under the hoz run.  At top of flue pipe never got to 250' and stayed  wet the whole time.  I rotted the flue/furnace/ in 4 mo.   You have to dry out the flue each hour to keep the pipe from just coming apart and fall down.  If you keep flue gas ( in my case) above 265'  with both hot water heater and furnace  above 265' will dry out the flue and will last very very long time.  I do my best to keep the flue gas temp as high as I can, Its the heat that's keeps the flue gas up the flue and out of the building,  unless you use a power vent  or PVC flue pipe.   

Comment by Bob Blanchette on July 14, 2014 at 7:40pm

+1 if flue gasses are too cool it will simply rot the pipe out. That's a big reason that double wall pipe (b vent) is used even when it's not required by code for low clearance.

Comment by Eric Kjelshus on May 28, 2014 at 7:07pm

I saw this a lot in the 60-70'.   not so much with 95% furnaces.   This will drop the flue temp some 100'  then the flue will condensate - stays wet then it just rots  outside in.   For fun turn the stat up to 85'  then use the IR photo to see heat loss.    Then look at temp at top of flue if under dew point then drip.  This will just rot the boiler/furnace/hot water and flue pipe

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Susan E. Buchan posted a status
"EEBA's Conference in St. Louis last week was a great success! Presentations at http://www.eeba.org/conference/2014-presentations."
10 hours ago
Jan Green replied to George Kopf's discussion Real Estate Professionals need our support - but how?
"It helps for companies to understand what the public wants and to educate them so that realtors are…"
10 hours ago
Hal Skinner replied to Hal Skinner's discussion An example of what an RCC can do with no R- insulation in the walls.
"Hi Bret and thans for the offer.   I sent you a friend request so I can send you a…"
10 hours ago
Kevin Jordan shared George Kopf's discussion on Facebook
10 hours ago
Kevin Jordan replied to George Kopf's discussion Real Estate Professionals need our support - but how?
"so who funds the greening of the inventory? would this be company by company?"
10 hours ago
Don Fitchett commented on Home Energy Magazine's blog post A Day in the Life of Learning
"This is a great addition to the July edition. Our PLC training uses the three areas too, but more…"
10 hours ago
Bret Curry replied to Hal Skinner's discussion An example of what an RCC can do with no R- insulation in the walls.
"Hal, Not sure if you serve the Little Rock market, or know of a company who does. If you know of…"
11 hours ago
Robert Cameron's discussion was featured

Air duct testing questions.

Many towns are now adopting the 2012 code about duct testing.  This is a great thing. However I…See More
11 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service