Thompson SFP House Detail

Cross-section of frost-protected shallow foundation for 12" truss-wall framing system.

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Robert Riversong on September 6, 2012 at 10:52am

I forgot to include the BSC link: http://www.buildingscience.com/documents/insights/bsi-003-concrete-...

The other consideration is the very high global warming potential of XPS, for which a new analysis by Alex Wilson and friends shows becomes worse over its lifetime at more than about R-15-20.

http://www2.buildinggreen.com/blogs/insulation-keep-us-warm-not-war...

http://www2.buildinggreen.com/content/global-warming-potential-insu...

Comment by Robert Riversong on September 6, 2012 at 10:47am

David,

This represents a balance between minimizing heat loss from a radiant slab into the ground and allowing sufficient downward heat loss to maintain the foundation as frost-proof (as well as moderately earth-coupling the house to the ground in the event of prolonged periods without supplemental heat, such as power outages or winter vacations).

Most proponents of superinsulated building would put more than R-10 under the slab, particularly a heated slab, with Passive House folks sometimes using as much as R-40. So I consider 2" XPS a minimum for this application, which includes FPSF, radiant and solar thermal mass slab.

Comment by David Williams on September 6, 2012 at 9:48am

Extruded (of course).  I also like the way that you achieve the R15 edge requirement.  I have modeled energy loss comparing 2" XPS with 1" XPS in well drained + soils climate zone 6. and have reservations about the added cost of 2" under the slab.  Knowing that you only get 1 shot at getting this right, I wonder what you thoughts are and where you would draw the line between 1" & 2".

Can you offer a link to the Building Science Corp reference?

Comment by Robert Riversong on September 6, 2012 at 9:18am

David,

Yes, that should have been noted in the section. I use a Tu-Tuf 4 mil laminated vapor barrier that is designed for sub-slab applications and is highly tear-resistant. All seams are taped, as well as all seams of the XPS (not EPS) insulation board.

It is a bad idea to put any "reservoir" layer of sand between the vapor barrier and the slab - Building Science Corp addresses this - as it is likely to create moisture problems. The slab finisher loves it because he can power trowel the slab and get home to his Budweiser sooner, but a vapor barrier does not cause slab cracking or curling.

Comment by David Williams on September 6, 2012 at 8:56am

Do you have a moisture barrier below the slabs' EPS?  I have found that a 1" layer of sand, placed over the EPS helped to protect both the insulation and vapor barrier.  This may have also provided some amount of moisture control during the curing phase.  I have had concrete contractors exclaim that slabs poured over EPS are very prone to cracking because of the way the the moisture escapes form the curing slab.

I have not had these cracking issues, on the radiant heated slabs that I have done over the past 30 years, but I have seen them in slabs that did not have proper edge insulation. 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

daniel manriquez replied to Trip's discussion Starting a Home Weatherization Business. Considering it...
"I would talk to Daniel Tait at http://www.nexusenergycenter.org/ . They do a lot of work with…"
39 minutes ago
Tom White's video was featured

Main St Nevada City, Historic Victorian energy upgrade story, Balance Point HP, Debra Little

Energy upgrade of historic 1866 Victorian by Gavin Healy & Dan Perunko of Balance Point Home Performance; Nevada City, CA. Extensive retrofit: attic, wall & ...
1 hour ago
Profile IconRamon Aguirre, John Kane, Bobby Hight and 3 more joined Home Energy Pros
3 hours ago
Jim Gunshinan commented on Jim Gunshinan's blog post My Energy Upgrade California—The Numbers Are In
"Thanks Nate for more good stuff to chew on—and nutritional! We may be running out to Home…"
12 hours ago
Tom Conlon commented on Jim Gunshinan's blog post My Energy Upgrade California—The Numbers Are In
"Jim,I just got around to re-reading your four-part series and I think this is a really interesting…"
12 hours ago
Nate Adams commented on Jim Gunshinan's blog post My Energy Upgrade California—The Numbers Are In
"$50 in health ain't much... not with my crappy high deductible plan. It buys half of a cold…"
12 hours ago
tedkidd commented on Jim Gunshinan's blog post My Energy Upgrade California—The Numbers Are In
"Yep, this thread has some good discussion. Back to dehumidification.  This may be…"
16 hours ago
Jim Gunshinan commented on Jim Gunshinan's blog post My Energy Upgrade California—The Numbers Are In
"Thanks for the clarification Nate. If I had the ability to precisely measure what $50 of health…"
18 hours ago
Nate Adams commented on Jim Gunshinan's blog post My Energy Upgrade California—The Numbers Are In
"Jim, Just a clarification, it's not DEhumidification I'm worried about in your climate,…"
18 hours ago
Chris McTaggart posted events
18 hours ago
Jim Gunshinan commented on Jim Gunshinan's blog post My Energy Upgrade California—The Numbers Are In
"Hi Nate, I'm glad this post has generated so much good discussion, since that is its main…"
18 hours ago
Diane Chojnowski's group was featured
Thumbnail

Facebook Pages

Does your company or organization have a Facebook Page?This group is for pros who have facebook…See More
18 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service