Thompson SFP House Detail

Cross-section of frost-protected shallow foundation for 12" truss-wall framing system.

Views: 404

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Robert Riversong on September 6, 2012 at 10:52am

I forgot to include the BSC link: http://www.buildingscience.com/documents/insights/bsi-003-concrete-...

The other consideration is the very high global warming potential of XPS, for which a new analysis by Alex Wilson and friends shows becomes worse over its lifetime at more than about R-15-20.

http://www2.buildinggreen.com/blogs/insulation-keep-us-warm-not-war...

http://www2.buildinggreen.com/content/global-warming-potential-insu...

Comment by Robert Riversong on September 6, 2012 at 10:47am

David,

This represents a balance between minimizing heat loss from a radiant slab into the ground and allowing sufficient downward heat loss to maintain the foundation as frost-proof (as well as moderately earth-coupling the house to the ground in the event of prolonged periods without supplemental heat, such as power outages or winter vacations).

Most proponents of superinsulated building would put more than R-10 under the slab, particularly a heated slab, with Passive House folks sometimes using as much as R-40. So I consider 2" XPS a minimum for this application, which includes FPSF, radiant and solar thermal mass slab.

Comment by David Williams on September 6, 2012 at 9:48am

Extruded (of course).  I also like the way that you achieve the R15 edge requirement.  I have modeled energy loss comparing 2" XPS with 1" XPS in well drained + soils climate zone 6. and have reservations about the added cost of 2" under the slab.  Knowing that you only get 1 shot at getting this right, I wonder what you thoughts are and where you would draw the line between 1" & 2".

Can you offer a link to the Building Science Corp reference?

Comment by Robert Riversong on September 6, 2012 at 9:18am

David,

Yes, that should have been noted in the section. I use a Tu-Tuf 4 mil laminated vapor barrier that is designed for sub-slab applications and is highly tear-resistant. All seams are taped, as well as all seams of the XPS (not EPS) insulation board.

It is a bad idea to put any "reservoir" layer of sand between the vapor barrier and the slab - Building Science Corp addresses this - as it is likely to create moisture problems. The slab finisher loves it because he can power trowel the slab and get home to his Budweiser sooner, but a vapor barrier does not cause slab cracking or curling.

Comment by David Williams on September 6, 2012 at 8:56am

Do you have a moisture barrier below the slabs' EPS?  I have found that a 1" layer of sand, placed over the EPS helped to protect both the insulation and vapor barrier.  This may have also provided some amount of moisture control during the curing phase.  I have had concrete contractors exclaim that slabs poured over EPS are very prone to cracking because of the way the the moisture escapes form the curing slab.

I have not had these cracking issues, on the radiant heated slabs that I have done over the past 30 years, but I have seen them in slabs that did not have proper edge insulation. 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Paul Raymer's blog post was featured

What does it take to be a certified Home Energy Professional Quality Control Inspector (HEP QCI)?

A quality control program requires knowing a lot about a lot of different subjects.  A HEP (BPI…See More
2 hours ago
Bryan Pringle replied to Bryan Pringle's discussion Dense packed cellulose in basement?
"Can you tell me more about how the plastic makes the moisture worse?   I understand that in…"
5 hours ago
Profile IconMatthew Cooke, yasmine smith, myacand heat and 2 more joined Home Energy Pros
5 hours ago
Bryan Pringle replied to Bryan Pringle's discussion Dense packed cellulose in basement?
"I like cellulose because of its air leakage reduction property and the ease of making a quality…"
5 hours ago
Bryan Pringle replied to Bryan Pringle's discussion Dense packed cellulose in basement?
"This example is the reverse of my suggestion.  I would do high end vapor barrier against…"
5 hours ago
Al Heath replied to Bryan Pringle's discussion Dense packed cellulose in basement?
"Really?  Go back and read these posts again.... "play ground for mold."  I…"
5 hours ago
Mary Desilva posted blog posts
6 hours ago
Kim Tanner posted a video

Single Family Residential Air Leakage Testing

This session will cover the basics of air leakage testing on a single family home as well as issues that affect the accuracy and repeatability of the test. T...
6 hours ago

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service