Cross-section of frost-protected shallow foundation for 12" truss-wall framing system.

Views: 481

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Robert Riversong on September 6, 2012 at 10:52am

I forgot to include the BSC link: http://www.buildingscience.com/documents/insights/bsi-003-concrete-...

The other consideration is the very high global warming potential of XPS, for which a new analysis by Alex Wilson and friends shows becomes worse over its lifetime at more than about R-15-20.

http://www2.buildinggreen.com/blogs/insulation-keep-us-warm-not-war...

http://www2.buildinggreen.com/content/global-warming-potential-insu...

Comment by Robert Riversong on September 6, 2012 at 10:47am

David,

This represents a balance between minimizing heat loss from a radiant slab into the ground and allowing sufficient downward heat loss to maintain the foundation as frost-proof (as well as moderately earth-coupling the house to the ground in the event of prolonged periods without supplemental heat, such as power outages or winter vacations).

Most proponents of superinsulated building would put more than R-10 under the slab, particularly a heated slab, with Passive House folks sometimes using as much as R-40. So I consider 2" XPS a minimum for this application, which includes FPSF, radiant and solar thermal mass slab.

Comment by David Williams on September 6, 2012 at 9:48am

Extruded (of course).  I also like the way that you achieve the R15 edge requirement.  I have modeled energy loss comparing 2" XPS with 1" XPS in well drained + soils climate zone 6. and have reservations about the added cost of 2" under the slab.  Knowing that you only get 1 shot at getting this right, I wonder what you thoughts are and where you would draw the line between 1" & 2".

Can you offer a link to the Building Science Corp reference?

Comment by Robert Riversong on September 6, 2012 at 9:18am

David,

Yes, that should have been noted in the section. I use a Tu-Tuf 4 mil laminated vapor barrier that is designed for sub-slab applications and is highly tear-resistant. All seams are taped, as well as all seams of the XPS (not EPS) insulation board.

It is a bad idea to put any "reservoir" layer of sand between the vapor barrier and the slab - Building Science Corp addresses this - as it is likely to create moisture problems. The slab finisher loves it because he can power trowel the slab and get home to his Budweiser sooner, but a vapor barrier does not cause slab cracking or curling.

Comment by David Williams on September 6, 2012 at 8:56am

Do you have a moisture barrier below the slabs' EPS?  I have found that a 1" layer of sand, placed over the EPS helped to protect both the insulation and vapor barrier.  This may have also provided some amount of moisture control during the curing phase.  I have had concrete contractors exclaim that slabs poured over EPS are very prone to cracking because of the way the the moisture escapes form the curing slab.

I have not had these cracking issues, on the radiant heated slabs that I have done over the past 30 years, but I have seen them in slabs that did not have proper edge insulation. 

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Jim Gunshinan's blog post was featured

A Healthy Home and a Healthy Bottom Line

There has been a lot of interest of late in the weatherization and broader home performance…See More
11 hours ago
Jonathan Beers commented on Home Energy Magazine's blog post Natural Gas is Becoming Less Attractive
"The carbon intensity of electricity use (lbs. of CO2/MWh) varies a lot from region to region. For…"
11 hours ago
Diane Chojnowski posted events
13 hours ago
Diane Chojnowski's 4 events were featured
13 hours ago
Diane Chojnowski updated an event
Thumbnail

Midwest Energy Solutions Conference at Chicago Hilton & Towers

March 7, 2017 to March 8, 2017
Once a year, MEEA invites all energy stakeholders to gather at our annual Midwest Energy Solutions…See More
14 hours ago
Home Energy Magazine's blog post was featured

Natural Gas is Becoming Less Attractive

The United States and Canada have been fortunate to have access to natural gas for space heating,…See More
14 hours ago
Home Energy Magazine posted a blog post

Natural Gas is Becoming Less Attractive

The United States and Canada have been fortunate to have access to natural gas for space heating,…See More
17 hours ago
Jim Gunshinan posted a blog post

A Healthy Home and a Healthy Bottom Line

There has been a lot of interest of late in the weatherization and broader home performance…See More
17 hours ago

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service