An ingenius way to vent out your bathroom fan.

An ingenius way to vent out your bathroom fan.

Sometimes the things we see are mind-blowing.

Views: 1024

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Jim Mikel on March 20, 2011 at 6:52pm

Jack, that is too funny!  I can only imagine how fast the blower door was turned off.  I had a similar situation where the owner had their dryer vent hooked up mutually with their bathroom fan (that the owner said did not work).  The only difference is that when the blower door turned on, lint was flying around that had been stuck in the bathroom vent!

Comment by Jack Baikoff on March 20, 2011 at 6:37pm
It's in Long Island, New York state. The owner did this himself after the installation of a bathroom fan. I've heard of at least one other instance of a bathroom fan being vented into a soil stack since I've taken this picture. There, when an auditor started the blower-door test the house filled with the stench coming from the bathroom fan.
Comment by Jim Mikel on March 19, 2011 at 7:44pm
Where was this?  In Missouri the building inspection codes are sooooo tough.  They would never allow it.
Comment by Eric Gribin on February 11, 2011 at 7:23am

What are they spending on air freshener?

Comment by Michael Dunseith on February 7, 2011 at 5:38pm

Mark,

BPI  requires that bath fans be vented outside.

No mention of soil stack pipes!

Kinda defeats the purpose of a bath fan to remove odors!

Comment by Mark Richardson on February 7, 2011 at 4:35pm

Yea, and the inside too!

wow...

Comment by Michael Dunseith on February 7, 2011 at 3:53pm
LOL, Thats a good one. Hose straight, no bends or Kinks. Love the duct tape. Cant make this stuff up.  I wonder what the program people would say? After all it is vented to the outside!

Groups

Latest Activity

Victor Rols Lindsay commented on Building Performance Institute's group Building Performance Institute (BPI)
"Does anyone know what/ how/ where in Ontario Canada to become BPI certified? The contact I have in…"
18 hours ago
Victor Rols Lindsay joined Building Performance Institute's group
Thumbnail

Building Performance Institute (BPI)

BPI is the nation's premier standards development, quality assurance and credentialing organization…See More
19 hours ago
Safe-R Insulation commented on Chris Laumer-Giddens's blog post Rock Wool Insulation for Floor of High Performance Tiny House
"Thanks for sharing this much information about roof wall…"
yesterday
Lindsay Bachman's 4 events were featured
Friday
Profile IconChris Hoskins and Ken Goodrich joined Home Energy Pros
Friday
Diane Chojnowski commented on Diane Chojnowski's event Better Buildings Peer Exchange Call: Home Improvement Catalyst: Keeping the Ball Rolling with Homeowners by Delivering More Value
"Hi Victor, All the BBRN Peer Exchange Calls are archived so you can listen anytime. Check out over…"
Friday
Victor Rols Lindsay commented on Diane Chojnowski's event Better Buildings Peer Exchange Call: Home Improvement Catalyst: Keeping the Ball Rolling with Homeowners by Delivering More Value
"Hi Diane, Unfortunately some of us are unable to partake in this webinar/ forum. Is there a…"
Friday
Ken Summers replied to Gregory Cisco's discussion Abandoning under-slab HVAC ductwork which fills with groundwater seasonally.
"My largest concern is moisture. I have seen mold forming on interior walls in the heating season…"
Thursday