ConfusedThermostat

Do you think that the HVAC Guy knew that this was not the optimal location for this thermostat? If we could only get everyone in our industries to do the right thing! Right Lee?

Views: 203

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Guy DuBois on January 17, 2012 at 4:54pm

It is a return and yes, I too believe that the problem is the cold air in the wall cavity that the T-stat is mounted to. This is a kneewall. I've heard some say that a T-stat in proximity to a return = bad. Seems to me that as you pointed out, the problem is with outdoor air migration into any cavity on which the stat may be mounted.

Comment by Evan Mills on December 9, 2011 at 9:51am

Help us understand a little more about what's implied by this photo.

Are we looking at a supply grill with cold air coming up the plenum behind the tstat, or are we looking at a return with some sort of cold air leakage into the return?  Judging by the warm grille surface, I'm assuming it's a return.  If so, isn't the problem more about the entry of cold air into the wall cavity (and influencing the tstat) than it is about the tstat location per se?

Either way, tstat surface seems to be at a similar temp as the rest of the room surfaces, but of course quite cold on/in the wall it's mounted to.  What's do we know about the resulting temperature where its sensor is?

Comment by Chris Heenan on December 1, 2011 at 4:37pm

shame shame. 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Stacy Hunt posted blog posts
3 hours ago
Kirsten Richnavsky added a discussion to the group Building Performance Institute (BPI)
Thumbnail

FREE BPI webinar: OSHA's Confined Spaces Rule Impacts Home Performance Workers

Check out this FREE webinar BPI is hosting on OSHA's Confined Spaces Rule Impacts Home Performance…See More
4 hours ago
SmithWatson posted a blog post

Dealing with the 5 Most Common Furnace and Heating Problems

Most people are reminded of the furnace repair service just when the fall or winter arrives.…See More
10 hours ago
SmithWatson shared Lester Shen's blog post on MySpace
10 hours ago
w d posted a discussion

AERC testing and Solar Grates update

AERC of WCMA has been created to test the effectiveness of window attachments and to design an…See More
19 hours ago
Profile IconRob Pender, Sheldon White and jerrycarter joined Home Energy Pros
20 hours ago
Morgan M Audetat commented on Tom White's blog post Embodied Energy: Minimizing Waste with Off-Site Construction
"What is new…"
20 hours ago
Mark posted events
23 hours ago

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service