sealed soffits near fan exhaust

sealing some soffits to fix ice damming

Views: 770

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Adin Maynard on July 30, 2011 at 4:47am
Bryce, thanks for the comment. Yes the flat was fully airsealed and brought up to R-60 with cellulose.  Each standard chute vent was improved, as can be seen in far left bay in image above. The few soffits near the bath fan were sealed to prevent exhaust air from bring brought back into the attic.  THere was plenty of 'low/high' ventilation, so this approach was taken. 
This past winter was crazy for ice damming. As a result, for attic retrofits, we are careful to improve and maintain soffit vents whenever possible.
Comment by Bryce Cramer on July 29, 2011 at 10:52am
Not sure if I understand how sealing the flow of air through the soffit will reduce ice damns. The better approach would be to stop the heat loss through the attic floor with a better insulation job. Then provide proper ventilation so that the roof deck remains cold and does not therefore melt snow that refreezes over a cold soffit. If the bathroom vent is just vented into the soffit area, I would think this would cause additional issues. The warm air (moist) air will hang inside the soffit area since the soffit is now sealed from the rest of the atiic....this should lead to moisture, mold and other problems in the roof deck above this soffit area.

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Ed Minch commented on Tom White's video
Thumbnail

Measured Home Performance: Assessment with a Infrared Camera

"I find it best to scan one time before the Blower Door is used to check for insulation and…"
yesterday
Profile IconLarry Kinney and teplie_poly joined Home Energy Pros
yesterday
Dan Antonioli replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"Okay, a couple of things. The 1.0 kW per square meter reference is only under the most ideal lab…"
Saturday
Hans Joachim Preiss replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"Dan, Let me attempt to compare apples with apples: My solar thermal system is located in…"
Friday
Dan Antonioli replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"Hi Hans, I don't know where you're located but where I am a 2.5 kw pv system costs closer…"
Friday
Hans Joachim Preiss replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"I use the combination of solar PV and heatpump water heaters in the vast majority of net-zero…"
Friday
Amber Vignieri posted a blog post
Friday
William Zwack added a discussion to the group Job Board
Thumbnail

Residental Energy Specialist: Washington, DC (or possibly telework)

Position Summary: CSRA Incorporated is searching for a Sr. Residential Building Energy Efficiency…See More
Friday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service