sealed soffits near fan exhaust

sealing some soffits to fix ice damming

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Adin Maynard on July 30, 2011 at 4:47am
Bryce, thanks for the comment. Yes the flat was fully airsealed and brought up to R-60 with cellulose.  Each standard chute vent was improved, as can be seen in far left bay in image above. The few soffits near the bath fan were sealed to prevent exhaust air from bring brought back into the attic.  THere was plenty of 'low/high' ventilation, so this approach was taken. 
This past winter was crazy for ice damming. As a result, for attic retrofits, we are careful to improve and maintain soffit vents whenever possible.
Comment by Bryce Cramer on July 29, 2011 at 10:52am
Not sure if I understand how sealing the flow of air through the soffit will reduce ice damns. The better approach would be to stop the heat loss through the attic floor with a better insulation job. Then provide proper ventilation so that the roof deck remains cold and does not therefore melt snow that refreezes over a cold soffit. If the bathroom vent is just vented into the soffit area, I would think this would cause additional issues. The warm air (moist) air will hang inside the soffit area since the soffit is now sealed from the rest of the atiic....this should lead to moisture, mold and other problems in the roof deck above this soffit area.

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Christopher Talarico posted a discussion

Heating with Tankless Water Heater & Hydronic Air Handler vs. Gas Furnace

Hi,I've looked around online and haven't found a lot of good information on home heating with…See More
18 minutes ago
Profile IconSara Sabol, Christopher Talarico and Aaren Stewart joined Home Energy Pros
2 hours ago
Hal Skinner replied to Andy Gostisha's discussion Disguising Ductless Heat Pump Units
"Hi Andy. The bare metal units on a roof stick out like a sore thumb .  Coating them with our…"
3 hours ago
Paul Morin replied to Stephen Standley's discussion Which reading is more reliable on a Minneapolis Duct Blaster?
"Sorry for chiming in so late.  Sean’s comment early on in the discussion was the closest…"
6 hours ago
jerry gentile posted a status
"hello- anyone challenge the written QCI exam?"
9 hours ago
Kevin Jordan posted photos
13 hours ago
Susan E. Buchan's event was featured

EEBA Excellence in Building Conference at Doubletree Union Station Hotel

September 23, 2014 at 8am to September 25, 2014 at 2pm
yesterday
Susan E. Buchan posted an event

EEBA Excellence in Building Conference at Doubletree Union Station Hotel

September 23, 2014 at 8am to September 25, 2014 at 2pm
yesterday

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service