Thompson SFP House Detail

Cross-section of frost-protected shallow foundation for 12" truss-wall framing system.

Views: 472

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Robert Riversong on September 6, 2012 at 10:52am

I forgot to include the BSC link: http://www.buildingscience.com/documents/insights/bsi-003-concrete-...

The other consideration is the very high global warming potential of XPS, for which a new analysis by Alex Wilson and friends shows becomes worse over its lifetime at more than about R-15-20.

http://www2.buildinggreen.com/blogs/insulation-keep-us-warm-not-war...

http://www2.buildinggreen.com/content/global-warming-potential-insu...

Comment by Robert Riversong on September 6, 2012 at 10:47am

David,

This represents a balance between minimizing heat loss from a radiant slab into the ground and allowing sufficient downward heat loss to maintain the foundation as frost-proof (as well as moderately earth-coupling the house to the ground in the event of prolonged periods without supplemental heat, such as power outages or winter vacations).

Most proponents of superinsulated building would put more than R-10 under the slab, particularly a heated slab, with Passive House folks sometimes using as much as R-40. So I consider 2" XPS a minimum for this application, which includes FPSF, radiant and solar thermal mass slab.

Comment by David Williams on September 6, 2012 at 9:48am

Extruded (of course).  I also like the way that you achieve the R15 edge requirement.  I have modeled energy loss comparing 2" XPS with 1" XPS in well drained + soils climate zone 6. and have reservations about the added cost of 2" under the slab.  Knowing that you only get 1 shot at getting this right, I wonder what you thoughts are and where you would draw the line between 1" & 2".

Can you offer a link to the Building Science Corp reference?

Comment by Robert Riversong on September 6, 2012 at 9:18am

David,

Yes, that should have been noted in the section. I use a Tu-Tuf 4 mil laminated vapor barrier that is designed for sub-slab applications and is highly tear-resistant. All seams are taped, as well as all seams of the XPS (not EPS) insulation board.

It is a bad idea to put any "reservoir" layer of sand between the vapor barrier and the slab - Building Science Corp addresses this - as it is likely to create moisture problems. The slab finisher loves it because he can power trowel the slab and get home to his Budweiser sooner, but a vapor barrier does not cause slab cracking or curling.

Comment by David Williams on September 6, 2012 at 8:56am

Do you have a moisture barrier below the slabs' EPS?  I have found that a 1" layer of sand, placed over the EPS helped to protect both the insulation and vapor barrier.  This may have also provided some amount of moisture control during the curing phase.  I have had concrete contractors exclaim that slabs poured over EPS are very prone to cracking because of the way the the moisture escapes form the curing slab.

I have not had these cracking issues, on the radiant heated slabs that I have done over the past 30 years, but I have seen them in slabs that did not have proper edge insulation. 

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Chris Heenan replied to Dale Hoffmeyer's discussion Friends and Family Referral Marketing
"I wish this forum had thumbs up buttons."
21 minutes ago
Russ Eisenberg replied to Dale Hoffmeyer's discussion Friends and Family Referral Marketing
"I like a 2 prong approach.  Refer someone and the referrer gets $X and the referral gets $x…"
50 minutes ago
Brian Toll replied to Dale Hoffmeyer's discussion Friends and Family Referral Marketing
"We get a handful of audit referrals each month by offering a $25 bounty to our customers through…"
1 hour ago
Tom White's video was featured

Hayward Healthy Home Principles and Products

Bill Hayward discusses the principles that were used to build the first Hayward Healthy Home and how the products were evaluated for toxicity before they wer...
1 hour ago
jackie harsha is now a member of Home Energy Pros
1 hour ago
Diane Chojnowski replied to Jan Green's discussion Retrofitting a 1979 Home to NAHB Silver or Gold - Pending Cert
"Jan, please post your slide deck or presentation here. We'd love to see it!"
1 hour ago
Jan Green posted a discussion

Retrofitting a 1979 Home to NAHB Silver or Gold - Pending Cert

I'm excited to be the lone speaker for the last in a series of lectures for the Scottsdale Green…See More
yesterday
Crosbey Archery liked Crosbey Archery's blog post How to improve the air quality in your home ?
Saturday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service