Looking at leaky can lights.

Leaky recessed-can lights were big energy wasters before they were sealed.

Views: 298


You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Adam Zielinski on March 24, 2011 at 12:01pm

Sealing up a can light with a foam board box is a code violation and unsafe.  If you do it, you need to use a non combustible material, like drywall, or one of the tenmat mineral wood recessed light covers.  http://www.tenmat-us.com/


The Cree LR6 LED conversion kits are nice, and should cut down on air leakage.  However if you install them in a non-IC rated can light housing, you still are not supposed to put insulation over the top of them.  So you would still have to baffle around the can in the attic.   The best option for Non-IC can lights is to remove them and replace them with IC rated fixtures, or some other alternative lighting. 


Comment by Jim Gunshinan on January 24, 2011 at 2:42pm

Haven't heard of that Bob, thanks for the heads up!


Comment by Bob Small on January 20, 2011 at 3:04pm
Have you seen the Cree LR6 LED conversion? www.creeLLS.com Lets you switch to an LED bulb in a sealed unit that screws in to your existing can housing. Great price too.
Comment by Jim Gunshinan on December 20, 2010 at 10:55am

Sorry, that was five years ago when Larry wrote his article.

Comment by Jim Gunshinan on December 20, 2010 at 10:54am

Larry Armanda, who used to call himself the "Can Man" because he spent a lot of time looking at and fixing recessed can light leaks, wrote about it for Home Energy in 2005 "Further Wrestling with Recessed-Can Lights" (Sept/Oct). He didn't find a great retrofit kit, but Builders Best and Lithonia Lighting put out some good kits for sealing the can lights. That was ten years ago, so things may have changed.


At our house the contractors used a non-expanding spray foam to seal the lights where the fixture meets the ceiling. (The retrofit kits have a spongy gasket that does the same thing.) Then our contractor made boxes out of foam board to insulate the can-lights on the attic side. There was one problem—the can lights with incandescent lights stay on for about two hours and then the thermal cut off switch turns them off. The insulation makes the light fixture heat up rapidly inside. Without a thermal cutoff switch, the fire danger would be pretty serious. We put CFLs in the can-lights and fixed that problem. We need a brighter light in one room, over a desk, and still have an incandescent there. It cuts off after a few hours and I take it as a signal to get away from my desk for a while! They should be CFLs that give that kind of light but we haven't found it yet.


Hope this helps!

Comment by dale conner on December 20, 2010 at 7:36am

Do you know of a good kit for converting the leaky lights to sealed ones? I pulled my leaky lights out of my house and replaced them with sealed lights but only because I was able to access them via the attic space.

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Grzegorz is now a member of Home Energy Pros
1 hour ago
Rod Fox replied to Rod Fox's discussion Utility Meter Accuracy
"Dennis, that's a ton of useful info and it will take me a bit to fully assimilate those…"
1 hour ago
Ben Haas replied to Rod Fox's discussion Utility Meter Accuracy
"Yup..... 1200 amp service to the compound.....  3 -400 amp panels, all single phase since 3…"
13 hours ago
Walter Ahlgrim replied to Rod Fox's discussion Utility Meter Accuracy
"The more I think about it if the problem cannot be the current transformers reading small loads,…"
18 hours ago
Dennis Heidner replied to Rod Fox's discussion Utility Meter Accuracy
"Note to readers 0.5A instead of 5A for reading with A/D.... the edit to correct that didn't…"
19 hours ago
Dennis Heidner replied to Rod Fox's discussion Utility Meter Accuracy
"Rod, I have some of the CT's that you referenced in the openenergymonitor system.  They…"
20 hours ago
Tauran Ivall replied to Tauran Ivall's discussion Energy Efficient Entry Door options out there?
"Graham, How did this Plasproinc door cost?  Do you have any photos you can share a link to?"
20 hours ago
Dennis Heidner replied to Rod Fox's discussion Utility Meter Accuracy
"1200A service... really?  or did you mean 200A.  That size service would likely result in…"
21 hours ago