sealed soffits near fan exhaust

sealing some soffits to fix ice damming

Views: 769


You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Adin Maynard on July 30, 2011 at 4:47am
Bryce, thanks for the comment. Yes the flat was fully airsealed and brought up to R-60 with cellulose.  Each standard chute vent was improved, as can be seen in far left bay in image above. The few soffits near the bath fan were sealed to prevent exhaust air from bring brought back into the attic.  THere was plenty of 'low/high' ventilation, so this approach was taken. 
This past winter was crazy for ice damming. As a result, for attic retrofits, we are careful to improve and maintain soffit vents whenever possible.
Comment by Bryce Cramer on July 29, 2011 at 10:52am
Not sure if I understand how sealing the flow of air through the soffit will reduce ice damns. The better approach would be to stop the heat loss through the attic floor with a better insulation job. Then provide proper ventilation so that the roof deck remains cold and does not therefore melt snow that refreezes over a cold soffit. If the bathroom vent is just vented into the soffit area, I would think this would cause additional issues. The warm air (moist) air will hang inside the soffit area since the soffit is now sealed from the rest of the atiic....this should lead to moisture, mold and other problems in the roof deck above this soffit area.


  • Add Videos
  • View All


Latest Activity

Benny hani replied to Benny hani's discussion Manual J online
"Thanks Bob"
6 hours ago
Benny hani replied to Benny hani's discussion Manual J online
"Thank you Isaac"
6 hours ago
Bob Blanchette commented on Amber Vignieri's blog post Even with Polar Vortex, Hourly Pricing Participants Saved
"Looks like the days of paying a fixed amount per KWh are rapidly coming to an end. Many utilities…"
8 hours ago
Bob Blanchette replied to Benny hani's discussion Manual J online
"Be sure the size that you ACCURATELY calculate actually gets installed. Often…"
8 hours ago
Bob Blanchette replied to Sean Lintow Sr's discussion Water Saver or Gimmick? in the group Best Practices (Residential)
"The problem is these devices NEVER pay for themselves. Water is cheap, about $3 per 1,000 gallons…"
8 hours ago
Bud Poll replied to Rob Madden's discussion Blower Door Testing on Energy Star v3 home
"Where was the blower set up, front door, other?  Was if located in an unobstructed area, not a…"
20 hours ago
David N. Armington liked John Poole's discussion Two Part Epoxy and Repair of Structural Wood
David N. Armington joined John Poole's group

Historic Home

Historic and vintage homes are significant to our cultural heritage, yet often lack energy…See More

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service