Its raining in my attic!!

Not enough insulation depth to stop condensation from forming on the surface of this spray foam roof line. The BER does not recommend installing a flash and batt attic roof installation unless you install enough spray foam to ensure that the surface temperature of the insulation does not drop below the dewpoint temperature of the warm, humid inside air. Also, the surface texture of the insulation will not allow the batt insulation to maintain complete contact with the spray foam, rendering the batt insulation an R-value of close to zero. Not to mention that gravity will eventually pull the insulation down and away from the roof deck in any case. It only takes a small air space to completely devalue the batt insulation. We recommend either spraying the full IECC code required R-value depth in the roof deck, or a flash and net/spray in place fiber or cellulose insulation that is fully supported with rigid backing so it does not sag and separate from the spray foam surface. In any case, the spray foam should be at a sufficient depth to ensure no condensation will form on its own, regardless of what additional insulation you install beneath it.

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Hal Skinner commented on Hal Skinner's group The RCC Classroom (Radiant Control Coatings)
"Kurt, check your emails.  Sent you a friend request you need to confirm then I can send you a…"
2 hours ago
Kevin Jordan replied to Kevin Jordan's discussion Does anyone have pointers on approaching real estate induatry.
"thank you sir!! If you have any other tips Id appreciate. I am new in this industry and I go and…"
2 hours ago
Bud Poll replied to Kurt Shafer's discussion Where can I find the best radiant barrier to install under my roof?
"Hi Kurt, You mentioned "On a RESNET discussion some insulation experts agreed that insulation…"
3 hours ago
Kurt Shafer commented on Hal Skinner's group The RCC Classroom (Radiant Control Coatings)
"Wow, I am very sad to hear about your eyes.  Would have been super to do that comparison. Good…"
4 hours ago
Hal Skinner commented on Hal Skinner's group The RCC Classroom (Radiant Control Coatings)
"My dads house has an attached garage.  It was converted to living space around 20 years…"
4 hours ago
Kurt Shafer commented on Hal Skinner's group The RCC Classroom (Radiant Control Coatings)
"Hal, do I see a terrific chance for you to show us all the power of your RCC? Your father's…"
5 hours ago
Hal Skinner replied to Kevin Jordan's discussion Does anyone have pointers on approaching real estate induatry.
"Kevin, Several years ago I worked closely with a general contractor and a real estate…"
5 hours ago
Hal Skinner commented on Hal Skinner's group The RCC Classroom (Radiant Control Coatings)
"That same RCC, used as paint on the ceiling of living space, will do the same as if it was applied…"
5 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service