Its raining in my attic!!

Not enough insulation depth to stop condensation from forming on the surface of this spray foam roof line. The BER does not recommend installing a flash and batt attic roof installation unless you install enough spray foam to ensure that the surface temperature of the insulation does not drop below the dewpoint temperature of the warm, humid inside air. Also, the surface texture of the insulation will not allow the batt insulation to maintain complete contact with the spray foam, rendering the batt insulation an R-value of close to zero. Not to mention that gravity will eventually pull the insulation down and away from the roof deck in any case. It only takes a small air space to completely devalue the batt insulation. We recommend either spraying the full IECC code required R-value depth in the roof deck, or a flash and net/spray in place fiber or cellulose insulation that is fully supported with rigid backing so it does not sag and separate from the spray foam surface. In any case, the spray foam should be at a sufficient depth to ensure no condensation will form on its own, regardless of what additional insulation you install beneath it.

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Hal Skinner replied to Hal Skinner's discussion How much heat energy is lost through the floor of a house?
"Good morning Bud, Took a quick look at the site and a couple others listed on the Yahoo…"
1 hour ago
Bud Poll replied to Hal Skinner's discussion How much heat energy is lost through the floor of a house?
"Hi Hal, Search "Basecalc basement heat loss".  From memory Canada (nrcan) has/had a…"
2 hours ago
Michael Dunseith posted photos
15 hours ago
Hal Skinner replied to Hal Skinner's discussion How much heat energy is lost through the floor of a house?
"II just remembered seeing a report by a federal adency, many years ago, that basically said …"
18 hours ago
Don Fitchett commented on Tom White's video
Thumbnail

Alliant Energy's PowerHouse TV: Sealing Leaky Ductwork

"Very educational. thanks for sharing Tom."
21 hours ago
Hal Skinner posted a discussion

How much heat energy is lost through the floor of a house?

I am asking this as I do not recall anyone speaking of any study to this end.  Many comments about…See More
21 hours ago

Mike Braun just added their location.
(via Member Map)

22 hours ago
Bud Poll replied to Bud Poll's discussion Another benefit from air sealing
"From my work in NY City many years ago, the critters I saw would never have fit through a quarter…"
yesterday

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service