Its raining in my attic!!

Not enough insulation depth to stop condensation from forming on the surface of this spray foam roof line. The BER does not recommend installing a flash and batt attic roof installation unless you install enough spray foam to ensure that the surface temperature of the insulation does not drop below the dewpoint temperature of the warm, humid inside air. Also, the surface texture of the insulation will not allow the batt insulation to maintain complete contact with the spray foam, rendering the batt insulation an R-value of close to zero. Not to mention that gravity will eventually pull the insulation down and away from the roof deck in any case. It only takes a small air space to completely devalue the batt insulation. We recommend either spraying the full IECC code required R-value depth in the roof deck, or a flash and net/spray in place fiber or cellulose insulation that is fully supported with rigid backing so it does not sag and separate from the spray foam surface. In any case, the spray foam should be at a sufficient depth to ensure no condensation will form on its own, regardless of what additional insulation you install beneath it.

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Mike Kandel added a discussion to the group Building Performance Institute (BPI)
Thumbnail

BPI's Home Energy Auditing Standard Published as ANSI Standard

The Building Performance Institute, Inc. (BPI) is proud to announce that BPI-1100-T-2014: Home…See More
51 minutes ago
Mike Kandel posted a discussion

BPI's Home Energy Auditing Standard Published as ANSI Standard

The Building Performance Institute, Inc. (BPI) is proud to announce that BPI-1100-T-2014: Home…See More
52 minutes ago
Hal Skinner posted a discussion
1 hour ago
Todd St.Clair joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
4 hours ago
Todd St.Clair replied to Jim Falakos's discussion Treat Software in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"How long ago did you buy this, if it was good for 5 months? And how much would you take for this."
4 hours ago
Bud Poll replied to Bud Poll's discussion Basing air exchange on house volume??
"Hi Sean, yes I am struggling with this and that is why I opened the discussion, so a definite…"
6 hours ago
Lynda Wright is now a member of Home Energy Pros
6 hours ago
Sean Lintow Sr replied to Bud Poll's discussion Basing air exchange on house volume??
"Sorry Bud but I think you need to clarify your issues with using volumes to calculate ACH As for…"
17 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service