Its raining in my attic!!

Not enough insulation depth to stop condensation from forming on the surface of this spray foam roof line. The BER does not recommend installing a flash and batt attic roof installation unless you install enough spray foam to ensure that the surface temperature of the insulation does not drop below the dewpoint temperature of the warm, humid inside air. Also, the surface texture of the insulation will not allow the batt insulation to maintain complete contact with the spray foam, rendering the batt insulation an R-value of close to zero. Not to mention that gravity will eventually pull the insulation down and away from the roof deck in any case. It only takes a small air space to completely devalue the batt insulation. We recommend either spraying the full IECC code required R-value depth in the roof deck, or a flash and net/spray in place fiber or cellulose insulation that is fully supported with rigid backing so it does not sag and separate from the spray foam surface. In any case, the spray foam should be at a sufficient depth to ensure no condensation will form on its own, regardless of what additional insulation you install beneath it.

Views: 333

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

John Nicholas replied to Sean Lintow Sr's discussion Blower Doors & Methods Used in the group Best Practices (Residential)
"Different houses, different problems, different approaches. A multipoint gives you a slope. The…"
2 hours ago
John Nicholas replied to Sean Lintow Sr's discussion Blower Doors & Methods Used in the group Best Practices (Residential)
"Bud,  I pretty much agree with Sean's points.  Given the time it takes to set up the…"
2 hours ago
Bud Poll replied to Sean Lintow Sr's discussion Blower Doors & Methods Used in the group Best Practices (Residential)
"A multi-point will take longer, but what will it do for the home owner?  Will it change the…"
4 hours ago
Sean Lintow Sr replied to Sean Lintow Sr's discussion Blower Doors & Methods Used in the group Best Practices (Residential)
"Hmmm good question - personally for air-leakage I would go with multi-point, preferably run from…"
5 hours ago
Richard Beyer posted a discussion

Media Reports Spray Polyurethane Foam Insulation spontaneously combusted a $5M Connecticut Home... "The Conclusion"

OFFICE OF THE FIRE MARSHAL1212 WHITTEMORE RDMIDDLEBURY, CONNECTICUT Fire Investigation Report –…See More
16 hours ago
Profile IconDavid Hepinstall and Matthew joined Home Energy Pros
22 hours ago
Steve Leombruno posted a blog post

Static power energy box

Just wondering if You've heard of this Static power energy box that boasts energy consumption…See More
yesterday
Bud Poll replied to Sean Lintow Sr's discussion Blower Doors & Methods Used in the group Best Practices (Residential)
"Hi Sean, I have a question for you.  If you were only interested in providing the best audit…"
yesterday

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service