Its raining in my attic!!

Not enough insulation depth to stop condensation from forming on the surface of this spray foam roof line. The BER does not recommend installing a flash and batt attic roof installation unless you install enough spray foam to ensure that the surface temperature of the insulation does not drop below the dewpoint temperature of the warm, humid inside air. Also, the surface texture of the insulation will not allow the batt insulation to maintain complete contact with the spray foam, rendering the batt insulation an R-value of close to zero. Not to mention that gravity will eventually pull the insulation down and away from the roof deck in any case. It only takes a small air space to completely devalue the batt insulation. We recommend either spraying the full IECC code required R-value depth in the roof deck, or a flash and net/spray in place fiber or cellulose insulation that is fully supported with rigid backing so it does not sag and separate from the spray foam surface. In any case, the spray foam should be at a sufficient depth to ensure no condensation will form on its own, regardless of what additional insulation you install beneath it.

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Hal Skinner commented on Hal Skinner's group The RCC Classroom (Radiant Control Coatings)
"That same RCC, used as paint on the ceiling of living space, will do the same as if it was applied…"
11 minutes ago
John Nicholas commented on Michael Stuart's group INFRARED THERMOGRAPHY USERS
"Don,  You are incorrect!  This is *NOT* the only course available that meets the ASNT…"
22 minutes ago
Craig Bird commented on Hal Skinner's group The RCC Classroom (Radiant Control Coatings)
"Correct, that is exactly what I said"
56 minutes ago
Hal Skinner commented on Hal Skinner's group The RCC Classroom (Radiant Control Coatings)
"At 1.7% enterng the structure, that Radiant barrier is now going to allow the R-rated insulation/s…"
1 hour ago
Craig Bird commented on Hal Skinner's group The RCC Classroom (Radiant Control Coatings)
"And how much of that 1.7% of the suns energy that got through the RB or RCC gets into the house,…"
1 hour ago
Hal Skinner commented on Hal Skinner's group The RCC Classroom (Radiant Control Coatings)
"OK.  This might be rudamentary here.  I want to make sure everyone understands how SOLAR…"
2 hours ago
Craig Bird commented on Hal Skinner's group The RCC Classroom (Radiant Control Coatings)
"Hal - I would disagree that radiant heat "goes through" fibrous insulation. Radiant heat…"
2 hours ago
Hal Skinner commented on Hal Skinner's group The RCC Classroom (Radiant Control Coatings)
"Hi KLurt. I would isagree with the comment that the attic floor is heated by the…"
2 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service