Its raining in my attic!!

Not enough insulation depth to stop condensation from forming on the surface of this spray foam roof line. The BER does not recommend installing a flash and batt attic roof installation unless you install enough spray foam to ensure that the surface temperature of the insulation does not drop below the dewpoint temperature of the warm, humid inside air. Also, the surface texture of the insulation will not allow the batt insulation to maintain complete contact with the spray foam, rendering the batt insulation an R-value of close to zero. Not to mention that gravity will eventually pull the insulation down and away from the roof deck in any case. It only takes a small air space to completely devalue the batt insulation. We recommend either spraying the full IECC code required R-value depth in the roof deck, or a flash and net/spray in place fiber or cellulose insulation that is fully supported with rigid backing so it does not sag and separate from the spray foam surface. In any case, the spray foam should be at a sufficient depth to ensure no condensation will form on its own, regardless of what additional insulation you install beneath it.

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Profile IconPing Wang, Whitney Cooper and Mike Burton joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
5 minutes ago
Ping Wang commented on Michael Stuart's group INFRARED THERMOGRAPHY USERS
"Hello Everyone, we produce and export Infrared heating lamp used for various food oven,industrial…"
9 minutes ago
Ping Wang joined Michael Stuart's group
Thumbnail

INFRARED THERMOGRAPHY USERS

This group is dedicated to knowledge sharing and discussion of infrared thermography for building…See More
14 minutes ago
Ping Wang shared Leslie McDowell, BPI's group on Facebook
17 minutes ago
Hal Skinner replied to Hal Skinner's discussion How much heat energy is lost through the floor of a house?
"Hello again Bud. The ORNL test that determined the R rating of R-0.0083 was based on…"
19 minutes ago
Ping Wang shared Diane Chojnowski's group on Facebook
28 minutes ago
Tom Mallard replied to Hal Skinner's discussion How much heat energy is lost through the floor of a house?
"For self-heating homes I'm using an insulation board under the joists to be able to use that…"
2 hours ago
Kevin Jordan shared a profile on Facebook
2 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service