Its raining in my attic!!

Not enough insulation depth to stop condensation from forming on the surface of this spray foam roof line. The BER does not recommend installing a flash and batt attic roof installation unless you install enough spray foam to ensure that the surface temperature of the insulation does not drop below the dewpoint temperature of the warm, humid inside air. Also, the surface texture of the insulation will not allow the batt insulation to maintain complete contact with the spray foam, rendering the batt insulation an R-value of close to zero. Not to mention that gravity will eventually pull the insulation down and away from the roof deck in any case. It only takes a small air space to completely devalue the batt insulation. We recommend either spraying the full IECC code required R-value depth in the roof deck, or a flash and net/spray in place fiber or cellulose insulation that is fully supported with rigid backing so it does not sag and separate from the spray foam surface. In any case, the spray foam should be at a sufficient depth to ensure no condensation will form on its own, regardless of what additional insulation you install beneath it.

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Hal Skinner replied to Hal Skinner's discussion How our ceramic based RCC works in the group Radiant Control Coatings
"Hey Tom, I will find the ORNL repoprt and post it.  It was a test on a ballasted roof sample.…"
5 hours ago
Tom Mallard replied to Hal Skinner's discussion How our ceramic based RCC works in the group Radiant Control Coatings
"So it seems that what you're saying is for heat-transfer the stuff has little resistance or…"
6 hours ago
Hal Skinner added a discussion to the group Radiant Control Coatings
Thumbnail

How our ceramic based RCC works

How our RCC worksEveryone knows, understands and accepts that RCCs reflect heat away from roofs,…See More
7 hours ago
Mike Kandel posted a discussion

Earn BPI CEUs at 3rd Annual Building Performance Forum

If you're searching for BPI CEUs, you'll find plenty at the 3rd Annual Building Performance Forum…See More
12 hours ago
Mike Kandel added a discussion to the group Building Performance Institute (BPI)
Thumbnail

Earn BPI CEUs at 3rd Annual Building Performance Forum

If you're searching for BPI CEUs, you'll find plenty at the 3rd Annual Building Performance Forum…See More
12 hours ago
Sean Lintow Sr commented on Christopher Morin's blog post UPDATED: Big Changes for Duct Testing in MA
"4% TOTAL Ted - Leakage to outside was stripped from the codes & for good reason"
15 hours ago
tedkidd commented on Christopher Morin's blog post UPDATED: Big Changes for Duct Testing in MA
"Wait!  4% total leakage or 4% leakage to outdoors? "
15 hours ago
Tom White's video was featured

Alliant Energy's PowerHouse TV: Sealing Leaky Ductwork

The PowerHouse television shows are written and produced by Alliant Energy, an energy services company based in Madison, Wis. The first PowerHouse episode was aired in September 1996 on KCRG-TV9 in Cedar Rapids, Iowa, and appears in six broadcast…
18 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service