ConfusedThermostat

Do you think that the HVAC Guy knew that this was not the optimal location for this thermostat? If we could only get everyone in our industries to do the right thing! Right Lee?

Views: 202

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Guy DuBois on January 17, 2012 at 4:54pm

It is a return and yes, I too believe that the problem is the cold air in the wall cavity that the T-stat is mounted to. This is a kneewall. I've heard some say that a T-stat in proximity to a return = bad. Seems to me that as you pointed out, the problem is with outdoor air migration into any cavity on which the stat may be mounted.

Comment by Evan Mills on December 9, 2011 at 9:51am

Help us understand a little more about what's implied by this photo.

Are we looking at a supply grill with cold air coming up the plenum behind the tstat, or are we looking at a return with some sort of cold air leakage into the return?  Judging by the warm grille surface, I'm assuming it's a return.  If so, isn't the problem more about the entry of cold air into the wall cavity (and influencing the tstat) than it is about the tstat location per se?

Either way, tstat surface seems to be at a similar temp as the rest of the room surfaces, but of course quite cold on/in the wall it's mounted to.  What's do we know about the resulting temperature where its sensor is?

Comment by Chris Heenan on December 1, 2011 at 4:37pm

shame shame. 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Colin Genge's video was featured

Passive House Testing Webinar (Feb 13, 2014)

We covered: - Measuring air leakage in a tight house; - New passive house testing equipment; - Powered flow hoods for accurate measurement of HRV ERV flow ra...
1 hour ago
Colin Genge posted events
9 hours ago
John Nicholas replied to Sean Lintow Sr's discussion Duct Testing - is a change in order? in the group Best Practices (Residential)
"Yes,  I was connected to the AH cabinet.  I find it easier in this area, given the common…"
11 hours ago
Colin Genge replied to Kim Tanner's discussion Blower Door Applications Guide in the group Multifamily Buildings
"This is a great guide that anyone testing with multiple fans should get hold  of. "
12 hours ago
Colin Genge added a discussion to the group Multifamily Buildings
Thumbnail

Just posted a lot of Multi-Family oriented blower door videos.

Just posted a lot of Multi-Family oriented blower door videos. Everything to do with Multi-Fan…See More
12 hours ago
Colin Genge joined Norm Bourassa's group
Thumbnail

Multifamily Buildings

For too long there has been relatively little EE focus on multifamily, but some new programs have…See More
12 hours ago
Colin Genge replied to Sean Lintow Sr's discussion Duct Testing - is a change in order? in the group Best Practices (Residential)
"I would assume you tested that high air leakage from the equipment cabinet and not on a flex…"
12 hours ago
Colin Genge replied to Sean Lintow Sr's discussion Blower Doors & Methods Used in the group Best Practices (Residential)
"For those of you who need  a Tectite report, FanTestic's report Generator is powerful…"