CAZ Testing

Views: 441

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Gary Baggett on February 19, 2011 at 5:18pm
Looks to me like that is a picture of CAZ testing...it's a combustable appliance. I do like the idea of CAST though. I'll ponder that one as I eat a grinder...
Comment by A. Tamasin Sterner on February 12, 2011 at 5:58am
Exactly.  My point is that we find teaching the entire combustion testing protocol to be more effective and easier for people to learn when we are specific about the test - what we are actually testing. 
Comment by Michael Dunseith on February 10, 2011 at 8:24pm

For thoses that need more infomation then a quick title...

 

The women in this picture is actually testing for ambient CO (Bugaboo for accuracy!) as well as spillage on a atmospheric Domestic hot water heater that is in a combustion appliance zone. Following BPI's combustion safety test procedure for vented appliances. (procedures number 3 and 5). Just a sample photo of some of the tests that are conducted in a CAZ! Here in the North east when someone states they are conducting CAZ testing, it just means that they will be performing all the tests required for that specific  appliance type. Without adding more acronyms to and industry that has too many already, we could start a new one combustion appliance safety testing (CAST).

This is a photo not a Q/A report,  lunch meat on bread is called sandwich, hero, grinder, hoagie, sub.

A picture says a thousand words - testing in a CAZ

Comment by A. Tamasin Sterner on February 10, 2011 at 7:20pm
Would love to influence the industry to stop using "CAZ Testing" when what they really mean, in the case of this photo, spillage testing.  CAZ means "combustion appliance zone" and really, all we really test regarding the CAZ itself is its relationship to the rest of the house and the outdoors, under normal (natural) and when we attempt to depressurize it the most (net worst case CAZ depressurization).  We call our testing by the name of the test:  ambient CO testing; undiluted flue gas testing for CO; draft pressure testing; spillage testing; combustible gas leak testing...  not "CAZ testing" unless we are talking specifically about the CAZ.  Just a thought!  Bugaboo for accuracy!
Comment by Michael Dunseith on December 5, 2010 at 1:48pm
The pitch here is about 1/2" per foot
Comment by Christian Asdal on December 2, 2010 at 9:50pm
the vent pipe appears to have inverse fall based on this picture....:)

Featured Forum Discussions

What causes a temperature plane in a home

Started by Energy Wise Solutions in HVAC. Last reply by Peter Krych on Friday. 4 Replies

Velocity Pressure Testing

Started by Horace Douglas Hunt, Jr. in General Forum. Last reply by Horace Douglas Hunt, Jr. Apr 15. 2 Replies

Videos

  • Add Videos
  • View All

Latest Activity

Alana Barnett added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

Energy audit equipment -all very new

I have a FLIR infrared camera, E40bx. Only used a few times -box, camera, charger, it is all there,…See More
10 hours ago
Alana Barnett joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
10 hours ago
Crosbey Archery posted a blog post
15 hours ago
Profile IconRon Sarrick and Alana Barnett joined Home Energy Pros
yesterday
Jim Fowler posted a discussion

TREAT modeling of mid-rise apartments low heating load

Does anyone have experience using TREAT to model mid-rise (3-story) apartment buildings with…See More
Friday
Peter Krych replied to Energy Wise Solutions's discussion What causes a temperature plane in a home
"I also should have asked where the furnace was located,basement,1st or 2nd floor. In any case the…"
Friday
Profile IconJim Fowler, Jennifer Flanagan, Debra Smit and 2 more joined Home Energy Pros
Friday
Eric Sperline added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

Wanted: Energy Auditing Equipment for sale

I am looking to buy a door frame panel that will accept a duct blaster fan.  I don't need the…See More
Friday

Home Energy Pros

Welcome to Home Energy Pros – the unique digital community by and for those who work in the home energy performance arena.

Home Energy Pros was founded by the developers of Home Energy Saver Pro (supported by the U.S. Department of Energy) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network. Please honor our Guidelines

© 2017   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service