Comment by Gary Baggett on February 19, 2011 at 5:18pm
Looks to me like that is a picture of CAZ testing...it's a combustable appliance. I do like the idea of CAST though. I'll ponder that one as I eat a grinder...
Comment by A. Tamasin Sterner on February 12, 2011 at 5:58am
Exactly.  My point is that we find teaching the entire combustion testing protocol to be more effective and easier for people to learn when we are specific about the test - what we are actually testing. 
Comment by Michael Dunseith on February 10, 2011 at 8:24pm

For thoses that need more infomation then a quick title...

 

The women in this picture is actually testing for ambient CO (Bugaboo for accuracy!) as well as spillage on a atmospheric Domestic hot water heater that is in a combustion appliance zone. Following BPI's combustion safety test procedure for vented appliances. (procedures number 3 and 5). Just a sample photo of some of the tests that are conducted in a CAZ! Here in the North east when someone states they are conducting CAZ testing, it just means that they will be performing all the tests required for that specific  appliance type. Without adding more acronyms to and industry that has too many already, we could start a new one combustion appliance safety testing (CAST).

This is a photo not a Q/A report,  lunch meat on bread is called sandwich, hero, grinder, hoagie, sub.

A picture says a thousand words - testing in a CAZ

Comment by A. Tamasin Sterner on February 10, 2011 at 7:20pm
Would love to influence the industry to stop using "CAZ Testing" when what they really mean, in the case of this photo, spillage testing.  CAZ means "combustion appliance zone" and really, all we really test regarding the CAZ itself is its relationship to the rest of the house and the outdoors, under normal (natural) and when we attempt to depressurize it the most (net worst case CAZ depressurization).  We call our testing by the name of the test:  ambient CO testing; undiluted flue gas testing for CO; draft pressure testing; spillage testing; combustible gas leak testing...  not "CAZ testing" unless we are talking specifically about the CAZ.  Just a thought!  Bugaboo for accuracy!
Comment by Michael Dunseith on December 5, 2010 at 1:48pm
The pitch here is about 1/2" per foot
Comment by Christian Asdal on December 2, 2010 at 9:50pm
the vent pipe appears to have inverse fall based on this picture....:)

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Sean Lintow Sr replied to Jim Gunshinan's discussion When your shower is in your kitchen...
"Cool, I can start cooking dinner, hop in and take a shower while making sure that…"
24 minutes ago
Jim Gunshinan posted a discussion

When your shower is in your kitchen...

Interesting question by Leanne Maxwell, former colleague at Home Energy:"Aside from all of the…See More
58 minutes ago
Carly@AirCycler posted a discussion

Using Two Exhaust Fans with AirCycler g2/FanConnect

A customer of ours recently asked if it was possible to operate two exhaust fans in two different…See More
3 hours ago
Brian Clavette added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

FLIR i-7 thermal imaging camera

Hi,I have a very lightly used FLIR 1-7 for sale.   i-7, serial # 60101-4267.  Full hard case and…See More
18 hours ago
Don Fitchett commented on Home Energy Magazine's blog post At Home with the Internet of Annoying Things
"True, for the smart consumer, the power savings should offset the additional power usage. For the…"
20 hours ago
Michael Dunseith posted an event

BPI Exams - All at Green Jobs Training Center

March 2, 2015 at 10am to March 31, 2015 at 2pm
Green Jobs Training Center is currently providing written and field exams for all of BPI…See More
21 hours ago
Michael Dunseith posted photos
21 hours ago
Dennis Heidner commented on Home Energy Magazine's blog post At Home with the Internet of Annoying Things
"Nice article. I am an electrical engineer, creating sensors for data collection and "possibly…"
22 hours ago

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service