Foundation Thermal Sketch

This is here to point out the total lack of recognition of heat-transfer, we just patch up the problem with some insulation here, some vapor barrier there.

Views: 66

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Tom Mallard on March 28, 2011 at 8:02am

The foundation is hard to control for heat-transfer due the compression loads, can't say I've solved anything other than to ponder insulation that can handle the loads to replace the board joists are usually nailed that's anchored to the concrete. That would be a worthy new product for energy conservation in home construction.

Another I've thought of tho' is where joists are open to the interior floor, that first foot needs to breathe but my opinion needs to be stuffed with insulation with the paper torn off to allow breathing of condensation but killing direct air movement.

That area is like a chiller in winter, the cold air from the wood gets warmed enough right there to rise and creep along the floor above the typical insulation just from sag between it and the wood!!

Comment by Tom Mallard on March 28, 2011 at 6:03am
Too true ... I'm such a misfit ...
Comment by Jim Peck on March 28, 2011 at 3:50am
As specie whom claims such intelligence, we do seem remarkably shortsighted

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Ed Minch commented on Tom White's video
Thumbnail

Measured Home Performance: Assessment with a Infrared Camera

"I find it best to scan one time before the Blower Door is used to check for insulation and…"
yesterday
Profile IconLarry Kinney and teplie_poly joined Home Energy Pros
yesterday
Dan Antonioli replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"Okay, a couple of things. The 1.0 kW per square meter reference is only under the most ideal lab…"
yesterday
Hans Joachim Preiss replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"Dan, Let me attempt to compare apples with apples: My solar thermal system is located in…"
yesterday
Dan Antonioli replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"Hi Hans, I don't know where you're located but where I am a 2.5 kw pv system costs closer…"
yesterday
Hans Joachim Preiss replied to Dan Antonioli's discussion Net Zero Energy Hot Water
"I use the combination of solar PV and heatpump water heaters in the vast majority of net-zero…"
Friday
Amber Vignieri posted a blog post
Friday
William Zwack added a discussion to the group Job Board
Thumbnail

Residental Energy Specialist: Washington, DC (or possibly telework)

Position Summary: CSRA Incorporated is searching for a Sr. Residential Building Energy Efficiency…See More
Friday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service