The cylindrical gray device sitting on top of this geothermal heat pump is a liquid line refrigerant dryer shipped inside the unit. The instructions provide it is to be installed in the liquid refrigerant line to remove moisture and contaminants. I found it inside the unit still wrapped in plastic. Apparently the installer thought, he didn't need no stinking filter dryer. Now the homeowner has no warranty because the unit was not properly installed. It was also short some 6,000 BTUH, most likely a refrigerant issue. Notice the white horizontal tubing headed to the top of the water heater. This is a desuperheater line where PEX is not allowed. Of course there were no worries, because the desuperheater was NEVER TURNED ON. There were over 20 code violations in this 2 year old Energy Star home where the homeowner consistently complained about high bills. At least he got a 54 HERS Index.

Views: 125

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Eric Kjelshus on January 21, 2014 at 7:43am

I like to see 2 hot water heating tanks the 1st is for the desuper heater and 2nd is hooked up to power  with out 2 tanks there is not energy saving.

I like to see more support on all pipes just to much wiggle room to pinch pipe.

If you flush 3 times and super deep vack under 400 Microns but over 100 ( so not suck out oil)  some feel its not needed to put in a filter dryer,  The filter dryer lower the total EER a little bit.  I feel its worth the 2% just to keep the TXV clean and no call backs.

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Jerry Lawrence posted events
21 hours ago
Morgan M Audetat replied to Bryan Pringle's discussion Dense packed cellulose in basement?
"Right you are. You have to ask: what will the cellulose contribute.  Here in Minneapolis we…"
22 hours ago
Morgan M Audetat replied to Tony Hicks's discussion Slab-on-grade Insulation
"All slabs float. We have been installing radiant floors on various slab constructions since the…"
23 hours ago
Tony Hicks replied to Tony Hicks's discussion Slab-on-grade Insulation
"2" XPS foam. I'd love an R-20. Having foam thick enough to get an R-20 would be…"
23 hours ago
Morgan M Audetat replied to Larry Schaffert's discussion How to correctly insulate exterior wall in a 1900 house?
"Sorry, I did missed the "siding nailed directly to the framing", my grandfather would…"
yesterday
Morgan M Audetat replied to Larry Schaffert's discussion How to correctly insulate exterior wall in a 1900 house?
"My own farm house is sided with 1/2" t&g pine boards and vinyl. We foamed then from the…"
yesterday
Tony Hicks replied to Tony Hicks's discussion Slab-on-grade Insulation
"Great thought! I think that would work. I'll have to put the cost together and see where I…"
yesterday
Danny Gough replied to Tony Hicks's discussion Slab-on-grade Insulation
"This is a tough detail because the foam on the edge of a slab doesn't provide sufficient…"
yesterday

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service