DSC00711

Views: 57

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Gary Baggett on October 12, 2011 at 1:15pm
This job was one where I was just running audits for one of the states WAP agencies, so normally I'm just writing reports and work orders. This was basiclly a "911" call to the agency and it was repaired immediately while my guys went on to the next audit. I was going through some pictures today where I proctor in NYC and found all the ones from this house. I'll try to put them up later if I get the chance.
Comment by George Whiting on October 11, 2011 at 2:00pm
That would be some job to clean that boiler and flue.  Was there even a nozzle on the burner? LOL
Comment by Gary Baggett on October 11, 2011 at 1:08pm

George, it was an oil fired boiler that was only maybe 3 years old. Look at the Efficiency numbers. Did you see the photos of the exterior of the house? The owner "didn't realize there was a problem"...all the black soot above the unit on the ceiling didn't give anything away...nor the 4' circle it burned into the ground outside...

 

Comment by George Whiting on October 10, 2011 at 3:18pm
I've never seen numbers like that on CO!

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Alan Gindt replied to Alan Gindt's discussion Minneapolis Blower Door System for sale in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Hi, Malcolm, Yes, I still have the Minneapolis Blower Door for sale as seen above in picture. If…"
1 hour ago
Malcolm McKelvie replied to Alan Gindt's discussion Minneapolis Blower Door System for sale in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Hi Alan, is it still for sale?"
4 hours ago
Malcolm McKelvie joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
4 hours ago
Hannah Finch posted a blog post

Want to Lead a Breakout Session at RaterFest! 2015?

We are adding something new to RaterFest! this year... attendee led breakout sessions on Saturday…See More
15 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"We're in climate zone 5 (near Santa Fe, NM) where it's dry as a bone. Gonna head to that…"
16 hours ago
Bud Poll replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"The two 4500 watt elements will never operate simultaneously.  It will be one or the…"
16 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Correction to this last posting... This model only operates one element at a time, not two in…"
16 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Agreed. Incidentally, I just called tech support at Bradford White (and actually spoke to a…"
16 hours ago