Excess parts - Who needs em?

The cylindrical gray device sitting on top of this geothermal heat pump is a liquid line refrigerant dryer shipped inside the unit. The instructions provide it is to be installed in the liquid refrigerant line to remove moisture and contaminants. I found it inside the unit still wrapped in plastic. Apparently the installer thought, he didn't need no stinking filter dryer. Now the homeowner has no warranty because the unit was not properly installed. It was also short some 6,000 BTUH, most likely a refrigerant issue. Notice the white horizontal tubing headed to the top of the water heater. This is a desuperheater line where PEX is not allowed. Of course there were no worries, because the desuperheater was NEVER TURNED ON. There were over 20 code violations in this 2 year old Energy Star home where the homeowner consistently complained about high bills. At least he got a 54 HERS Index.

Views: 119

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Eric Kjelshus on January 21, 2014 at 7:43am

I like to see 2 hot water heating tanks the 1st is for the desuper heater and 2nd is hooked up to power  with out 2 tanks there is not energy saving.

I like to see more support on all pipes just to much wiggle room to pinch pipe.

If you flush 3 times and super deep vack under 400 Microns but over 100 ( so not suck out oil)  some feel its not needed to put in a filter dryer,  The filter dryer lower the total EER a little bit.  I feel its worth the 2% just to keep the TXV clean and no call backs.

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Nate Adams's discussion was featured
5 minutes ago
Bud Poll replied to Bud Poll's discussion CO poisoning in Yarmouth Maine
"Hi Chad, I sure would like to hear the follow-up on what caused the CO issue down there.  As…"
3 hours ago
Chad Mcaulife replied to Bud Poll's discussion CO poisoning in Yarmouth Maine
"I got a call yesterday from a homeowner who had a direct vent furnace installed a year ago and she…"
4 hours ago
Windzer Pierre-Louis replied to Matthew P's discussion Needed: Gas Detector and CO Detector. What do you recommend?
"Matt, I am new to the industry, less than 6 months. I love the mission of the industry; to bring…"
4 hours ago
Todd Collins replied to Nate Adams's discussion One Knob and the Pain That Inspired It
"Home performance is about comfort and energy savings.  We are working on a document about…"
5 hours ago
tedkidd commented on Shawna Henderson's blog post Sales funnels are funny shaped things
"Nice Venn Diagram. Product sales vs Consultative Solutions sales. We like the Sandler Selling…"
5 hours ago
Andrew Aliferis replied to Patrick Michaelyan's discussion Proper means to "plug" flue pipes after testing gas appliances.
"Patrick, These are what works for the programs I am involved in New Jersey and Pennsylvania. They…"
5 hours ago
Profile IconTravis Thom and Amita Singh joined Home Energy Pros
6 hours ago

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service