Excess parts - Who needs em?

The cylindrical gray device sitting on top of this geothermal heat pump is a liquid line refrigerant dryer shipped inside the unit. The instructions provide it is to be installed in the liquid refrigerant line to remove moisture and contaminants. I found it inside the unit still wrapped in plastic. Apparently the installer thought, he didn't need no stinking filter dryer. Now the homeowner has no warranty because the unit was not properly installed. It was also short some 6,000 BTUH, most likely a refrigerant issue. Notice the white horizontal tubing headed to the top of the water heater. This is a desuperheater line where PEX is not allowed. Of course there were no worries, because the desuperheater was NEVER TURNED ON. There were over 20 code violations in this 2 year old Energy Star home where the homeowner consistently complained about high bills. At least he got a 54 HERS Index.

Views: 125

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Eric Kjelshus on January 21, 2014 at 7:43am

I like to see 2 hot water heating tanks the 1st is for the desuper heater and 2nd is hooked up to power  with out 2 tanks there is not energy saving.

I like to see more support on all pipes just to much wiggle room to pinch pipe.

If you flush 3 times and super deep vack under 400 Microns but over 100 ( so not suck out oil)  some feel its not needed to put in a filter dryer,  The filter dryer lower the total EER a little bit.  I feel its worth the 2% just to keep the TXV clean and no call backs.

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Lars olsen posted a blog post
7 hours ago
Eric Kjelshus replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"The heat exchanger gets burnt out, if presser is to high or if mix is to rich, then I see holes in…"
18 hours ago
Hans Joachim Preiss replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"Good discussion. I came across this comprehensive presentation by Gas Consultants on the effects at…"
19 hours ago
Dale Pickard replied to Rod Fox's discussion Does altitude affect AFUE? or just the input/output BTUs?
"Excellent reply Hans. I think that there isnt' a good general answer to this question but that…"
22 hours ago
Mary Desilva posted blog posts
23 hours ago
David Heslam joined David Eggleton's group
Thumbnail

1000 Home Challenge

Linda Wigington distinguished between deep retrofits & deep energy reductions, thus expanding…See More
yesterday
Jose Macho commented on Charlie Hewitt's blog post Revisiting Heat Pump Water Heaters
"I am aware of homeowner dissatisfaction of hybrid units not performing due to location,…"
yesterday
KC Brown added a discussion to the group Job Board
Thumbnail

Job Opening: SR. ENERGY ENGINEER - CLEAResult, Energy Efficiency Leader (Pennsylvania)

POSITION:  Sr. Energy EngineerREFERNCE CODE:  2015-2197 JOB DESCRIPTION:CLEAResult is a leading…See More
yesterday

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service