Excess parts - Who needs em?

The cylindrical gray device sitting on top of this geothermal heat pump is a liquid line refrigerant dryer shipped inside the unit. The instructions provide it is to be installed in the liquid refrigerant line to remove moisture and contaminants. I found it inside the unit still wrapped in plastic. Apparently the installer thought, he didn't need no stinking filter dryer. Now the homeowner has no warranty because the unit was not properly installed. It was also short some 6,000 BTUH, most likely a refrigerant issue. Notice the white horizontal tubing headed to the top of the water heater. This is a desuperheater line where PEX is not allowed. Of course there were no worries, because the desuperheater was NEVER TURNED ON. There were over 20 code violations in this 2 year old Energy Star home where the homeowner consistently complained about high bills. At least he got a 54 HERS Index.

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Eric Kjelshus on January 21, 2014 at 7:43am

I like to see 2 hot water heating tanks the 1st is for the desuper heater and 2nd is hooked up to power  with out 2 tanks there is not energy saving.

I like to see more support on all pipes just to much wiggle room to pinch pipe.

If you flush 3 times and super deep vack under 400 Microns but over 100 ( so not suck out oil)  some feel its not needed to put in a filter dryer,  The filter dryer lower the total EER a little bit.  I feel its worth the 2% just to keep the TXV clean and no call backs.

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Kelly replied to Chad Mcaulife's discussion BPI QCI Cert.
"Hi Chad, I got the QCI during the pilot, but the written test hasn't changed much. The quiz…"
20 minutes ago
Hal Skinner posted a discussion

Any success getting landlords to energy upgrade a single family rental unit?

Any success getting landlords to energy upgrade a single family rental unit? Multi-family dwelling…See More
23 minutes ago
Steve Waclo replied to Linda Wigington's discussion Low-cost electricity monitoring: Accuracy & Applications in the group 1000 Home Challenge
"Trying again:"
2 hours ago
Steve Waclo replied to Linda Wigington's discussion Low-cost electricity monitoring: Accuracy & Applications in the group 1000 Home Challenge
"Upload issues with pics."
2 hours ago
Steve Waclo replied to Linda Wigington's discussion Low-cost electricity monitoring: Accuracy & Applications in the group 1000 Home Challenge
"Hello all, Finally made time to install the Efergy E2 system I bought and here's an email I…"
2 hours ago
Jason posted a discussion

Crawl Encapsulation

Hello All,I'm just looking to the forum to see what you guys think of my crawl encapsulation and if…See More
2 hours ago
David Krueger added a discussion to the group Job Board
Thumbnail

Northern California Energy Efficiency Enthusiast Needed

We're busy and we are hiring retrofit technicians and energy auditors. You are immediately eligible…See More
3 hours ago
Al Tibbs posted photos
3 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service