Excess parts - Who needs em?

The cylindrical gray device sitting on top of this geothermal heat pump is a liquid line refrigerant dryer shipped inside the unit. The instructions provide it is to be installed in the liquid refrigerant line to remove moisture and contaminants. I found it inside the unit still wrapped in plastic. Apparently the installer thought, he didn't need no stinking filter dryer. Now the homeowner has no warranty because the unit was not properly installed. It was also short some 6,000 BTUH, most likely a refrigerant issue. Notice the white horizontal tubing headed to the top of the water heater. This is a desuperheater line where PEX is not allowed. Of course there were no worries, because the desuperheater was NEVER TURNED ON. There were over 20 code violations in this 2 year old Energy Star home where the homeowner consistently complained about high bills. At least he got a 54 HERS Index.

Views: 125

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Eric Kjelshus on January 21, 2014 at 7:43am

I like to see 2 hot water heating tanks the 1st is for the desuper heater and 2nd is hooked up to power  with out 2 tanks there is not energy saving.

I like to see more support on all pipes just to much wiggle room to pinch pipe.

If you flush 3 times and super deep vack under 400 Microns but over 100 ( so not suck out oil)  some feel its not needed to put in a filter dryer,  The filter dryer lower the total EER a little bit.  I feel its worth the 2% just to keep the TXV clean and no call backs.

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Malcolm McKelvie replied to Alan Gindt's discussion Minneapolis Blower Door System for sale in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"yes I would pay the delivery fee!"
3 hours ago
Alan Gindt replied to Alan Gindt's discussion Minneapolis Blower Door System for sale in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"Malcolm, If you want to pay delivery from USA we can talk. Otherwise no thanks."
3 hours ago
Malcolm McKelvie replied to Alan Gindt's discussion Minneapolis Blower Door System for sale in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"How old is it? I assume it is in good working order? I'm interested in it but the price needs…"
5 hours ago
William H Nickerson replied to Kim Tanner's discussion Fantastic innovation
"So that's where you use those True Flow plates....."
8 hours ago
Colin Genge updated an event
Thumbnail

Passive House Testing Webinar with Kevin Brennan of the Passive House Academy at Online

September 29, 2015 from 1pm to 2pm
Tests needed to qualify as a passive houseWhy we’re seeing an increase in PH buildingsBest…See More
15 hours ago
Colin Genge updated an event
Thumbnail

DM32 Smart Gauge 101 Webinar at Online

September 22, 2015 from 1pm to 2pm
Webinar Learning Objectives:Gauge settings and operationCalculate results in the gaugeUpdate the…See More
15 hours ago
Colin Genge updated an event
Thumbnail

Blower Door 101 Webinar at Online

September 15, 2015 from 1pm to 2pm
See how easy it is to do your first test. Learn tips to perform your first duct test in only twenty…See More
15 hours ago
Colin Genge updated an event
Thumbnail

Zone Pressure Diagnostics (ZPD) with Bill Eckman of NME$A Webinar at Online

September 10, 2015 from 1pm to 2pm
Benefits and limitations of Zonal Pressure Diagnostics (ZPD).Best practices for accurate…See More
15 hours ago

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service