Dense Packed Ducts

Return ducts used floor/ceiling joist and balloon frame wall cavities for return air. Once the walls were insulated the furnace suffocated and pulled all return air from the basement. The worst case CAZ was -12.3pa causing the furnace to backdraft and the basement to reach 97ppm of CO.

Views: 236

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Joseph J. Ilacqua on November 30, 2012 at 11:50am

Yes in my location in upstate NY this is a common practice. Even more common while dense packing tuck under garage ceilings. Be carefull and beware. That is why we do constant pre and post job inspections. Sometimes even with a great inspection these can be missed. Learn from someones else's mistakes and try not to make the same one.

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Hal Skinner replied to Richard Beyer's discussion Media Reports Spray Polyurethane Foam Insulation spontaneously combusted a $5M Connecticut Home... "The Conclusion"
""fire origin had overheated and ignited during the curing process." No attorney…"
9 hours ago
John Nicholas replied to Sean Lintow Sr's discussion Blower Doors & Methods Used in the group Best Practices (Residential)
"Different houses, different problems, different approaches. A multipoint gives you a slope. The…"
18 hours ago
John Nicholas replied to Sean Lintow Sr's discussion Blower Doors & Methods Used in the group Best Practices (Residential)
"Bud,  I pretty much agree with Sean's points.  Given the time it takes to set up the…"
18 hours ago
Bud Poll replied to Sean Lintow Sr's discussion Blower Doors & Methods Used in the group Best Practices (Residential)
"A multi-point will take longer, but what will it do for the home owner?  Will it change the…"
20 hours ago
Sean Lintow Sr replied to Sean Lintow Sr's discussion Blower Doors & Methods Used in the group Best Practices (Residential)
"Hmmm good question - personally for air-leakage I would go with multi-point, preferably run from…"
22 hours ago
Richard Beyer posted a discussion

Media Reports Spray Polyurethane Foam Insulation spontaneously combusted a $5M Connecticut Home... "The Conclusion"

OFFICE OF THE FIRE MARSHAL1212 WHITTEMORE RDMIDDLEBURY, CONNECTICUT Fire Investigation Report –…See More
yesterday
Profile IconDavid Hepinstall and Matthew joined Home Energy Pros
yesterday
Steve Leombruno posted a blog post

Static power energy box

Just wondering if You've heard of this Static power energy box that boasts energy consumption…See More
yesterday

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service