CAZ Testing

Views: 441

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Gary Baggett on February 19, 2011 at 5:18pm
Looks to me like that is a picture of CAZ testing...it's a combustable appliance. I do like the idea of CAST though. I'll ponder that one as I eat a grinder...
Comment by A. Tamasin Sterner on February 12, 2011 at 5:58am
Exactly.  My point is that we find teaching the entire combustion testing protocol to be more effective and easier for people to learn when we are specific about the test - what we are actually testing. 
Comment by Michael Dunseith on February 10, 2011 at 8:24pm

For thoses that need more infomation then a quick title...

 

The women in this picture is actually testing for ambient CO (Bugaboo for accuracy!) as well as spillage on a atmospheric Domestic hot water heater that is in a combustion appliance zone. Following BPI's combustion safety test procedure for vented appliances. (procedures number 3 and 5). Just a sample photo of some of the tests that are conducted in a CAZ! Here in the North east when someone states they are conducting CAZ testing, it just means that they will be performing all the tests required for that specific  appliance type. Without adding more acronyms to and industry that has too many already, we could start a new one combustion appliance safety testing (CAST).

This is a photo not a Q/A report,  lunch meat on bread is called sandwich, hero, grinder, hoagie, sub.

A picture says a thousand words - testing in a CAZ

Comment by A. Tamasin Sterner on February 10, 2011 at 7:20pm
Would love to influence the industry to stop using "CAZ Testing" when what they really mean, in the case of this photo, spillage testing.  CAZ means "combustion appliance zone" and really, all we really test regarding the CAZ itself is its relationship to the rest of the house and the outdoors, under normal (natural) and when we attempt to depressurize it the most (net worst case CAZ depressurization).  We call our testing by the name of the test:  ambient CO testing; undiluted flue gas testing for CO; draft pressure testing; spillage testing; combustible gas leak testing...  not "CAZ testing" unless we are talking specifically about the CAZ.  Just a thought!  Bugaboo for accuracy!
Comment by Michael Dunseith on December 5, 2010 at 1:48pm
The pitch here is about 1/2" per foot
Comment by Christian Asdal on December 2, 2010 at 9:50pm
the vent pipe appears to have inverse fall based on this picture....:)

Latest Activity

Sean Lintow Sr replied to Martin Newmark's discussion Best Practice for Retrofit Insulation on Modern Knee Walls in Attics
"It gets down to the size of the crawl - I can't recall where I saw it but one contractor cuts…"
51 minutes ago
Green ID posted blog posts
13 hours ago
Home Energy Magazine's blog post was featured

New Report Shows Big Jump in Net-Zero Energy Homes

Net-zero energy homes seem to be growing their way out of a purely niche market. The number of zero…See More
14 hours ago
Home Energy Magazine posted a blog post

New Report Shows Big Jump in Net-Zero Energy Homes

Net-zero energy homes seem to be growing their way out of a purely niche market. The number of zero…See More
15 hours ago

Photos

Loading…
  • Add Photos
  • View All

© 2017   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service