Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Gary Baggett on February 19, 2011 at 5:18pm
Looks to me like that is a picture of CAZ testing...it's a combustable appliance. I do like the idea of CAST though. I'll ponder that one as I eat a grinder...
Comment by A. Tamasin Sterner on February 12, 2011 at 5:58am
Exactly.  My point is that we find teaching the entire combustion testing protocol to be more effective and easier for people to learn when we are specific about the test - what we are actually testing. 
Comment by Michael Dunseith on February 10, 2011 at 8:24pm

For thoses that need more infomation then a quick title...

 

The women in this picture is actually testing for ambient CO (Bugaboo for accuracy!) as well as spillage on a atmospheric Domestic hot water heater that is in a combustion appliance zone. Following BPI's combustion safety test procedure for vented appliances. (procedures number 3 and 5). Just a sample photo of some of the tests that are conducted in a CAZ! Here in the North east when someone states they are conducting CAZ testing, it just means that they will be performing all the tests required for that specific  appliance type. Without adding more acronyms to and industry that has too many already, we could start a new one combustion appliance safety testing (CAST).

This is a photo not a Q/A report,  lunch meat on bread is called sandwich, hero, grinder, hoagie, sub.

A picture says a thousand words - testing in a CAZ

Comment by A. Tamasin Sterner on February 10, 2011 at 7:20pm
Would love to influence the industry to stop using "CAZ Testing" when what they really mean, in the case of this photo, spillage testing.  CAZ means "combustion appliance zone" and really, all we really test regarding the CAZ itself is its relationship to the rest of the house and the outdoors, under normal (natural) and when we attempt to depressurize it the most (net worst case CAZ depressurization).  We call our testing by the name of the test:  ambient CO testing; undiluted flue gas testing for CO; draft pressure testing; spillage testing; combustible gas leak testing...  not "CAZ testing" unless we are talking specifically about the CAZ.  Just a thought!  Bugaboo for accuracy!
Comment by Michael Dunseith on December 5, 2010 at 1:48pm
The pitch here is about 1/2" per foot
Comment by Christian Asdal on December 2, 2010 at 9:50pm
the vent pipe appears to have inverse fall based on this picture....:)

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

tedkidd commented on Scott Mellberg's blog post Lessons from Energy Efficiency Advisors: Getting Homeowners Onboard with Home Performance
"David,  I don't think forcing people to do things works out well for anyone.  Any…"
37 minutes ago
David Eakin commented on Scott Mellberg's blog post Lessons from Energy Efficiency Advisors: Getting Homeowners Onboard with Home Performance
""I believe it is our job to educate the consumer, understand the problems, help them…"
50 minutes ago
Profile IconGary Fitzgerald, LOUIS ANDERSON and Jeremy Hargreaves joined Home Energy Pros
1 hour ago
eric anderson replied to Tom Conlon's discussion Whole House Fans - Love 'Em or Not?
"In Connecticut’s climate, I am not in favor of them . Either they are the big old style that…"
2 hours ago
Don Fitchett replied to Brandon Walton's discussion 12 Things Every Home Performance Contractor Should Have on Their Work Truck
"Every little bit helps. :)"
2 hours ago
Tom White commented on Scott Mellberg's blog post Lessons from Energy Efficiency Advisors: Getting Homeowners Onboard with Home Performance
"Ted, I understand and share your concern about the lack of guidance on the part of the "Home…"
2 hours ago
Mike Kandel added a discussion to the group Building Performance Institute (BPI)
3 hours ago
Mike Kandel posted a discussion
4 hours ago
tedkidd commented on Scott Mellberg's blog post Lessons from Energy Efficiency Advisors: Getting Homeowners Onboard with Home Performance
"David,  Please think some of these things through.  If programs suck so much, how can…"
4 hours ago
Hannah Finch posted a blog post

Stump Duncan, Innovate with Colby, and Save on RaterFest! 2014

RaterFest! 2014 Speaker Spotlight!Presenter:  Duncan PrahlTopic: Duck, Ducks, and more Ducts…See More
5 hours ago
David Eakin commented on Scott Mellberg's blog post Lessons from Energy Efficiency Advisors: Getting Homeowners Onboard with Home Performance
"Consultation and education are all well and good, but we have found that the…"
5 hours ago
Kari Sauder commented on Scott Mellberg's blog post Lessons from Energy Efficiency Advisors: Getting Homeowners Onboard with Home Performance
"I just had a customer bail out of the whole house approach over the weekend.  It is a small…"