CAZ Testing

Views: 441

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Gary Baggett on February 19, 2011 at 5:18pm
Looks to me like that is a picture of CAZ testing...it's a combustable appliance. I do like the idea of CAST though. I'll ponder that one as I eat a grinder...
Comment by A. Tamasin Sterner on February 12, 2011 at 5:58am
Exactly.  My point is that we find teaching the entire combustion testing protocol to be more effective and easier for people to learn when we are specific about the test - what we are actually testing. 
Comment by Michael Dunseith on February 10, 2011 at 8:24pm

For thoses that need more infomation then a quick title...

 

The women in this picture is actually testing for ambient CO (Bugaboo for accuracy!) as well as spillage on a atmospheric Domestic hot water heater that is in a combustion appliance zone. Following BPI's combustion safety test procedure for vented appliances. (procedures number 3 and 5). Just a sample photo of some of the tests that are conducted in a CAZ! Here in the North east when someone states they are conducting CAZ testing, it just means that they will be performing all the tests required for that specific  appliance type. Without adding more acronyms to and industry that has too many already, we could start a new one combustion appliance safety testing (CAST).

This is a photo not a Q/A report,  lunch meat on bread is called sandwich, hero, grinder, hoagie, sub.

A picture says a thousand words - testing in a CAZ

Comment by A. Tamasin Sterner on February 10, 2011 at 7:20pm
Would love to influence the industry to stop using "CAZ Testing" when what they really mean, in the case of this photo, spillage testing.  CAZ means "combustion appliance zone" and really, all we really test regarding the CAZ itself is its relationship to the rest of the house and the outdoors, under normal (natural) and when we attempt to depressurize it the most (net worst case CAZ depressurization).  We call our testing by the name of the test:  ambient CO testing; undiluted flue gas testing for CO; draft pressure testing; spillage testing; combustible gas leak testing...  not "CAZ testing" unless we are talking specifically about the CAZ.  Just a thought!  Bugaboo for accuracy!
Comment by Michael Dunseith on December 5, 2010 at 1:48pm
The pitch here is about 1/2" per foot
Comment by Christian Asdal on December 2, 2010 at 9:50pm
the vent pipe appears to have inverse fall based on this picture....:)

Photos

Loading…
  • Add Photos
  • View All

Latest Activity

Bob Blanchette liked Diane Chojnowski's discussion Now you can "LIKE" posts on Home Energy Pros!
47 minutes ago
JC NATALE posted photos
18 hours ago
Mike Burton replied to Amos Dunham's discussion ISO blower door or other equipment
"Are you still looking?  I have rarely used Minneapolis Blower Door and Duct Blaster Systems I…"
yesterday
Jonny Fisher posted a discussion

Used energy equipment for sale (blower door, duct blaster

I've got some used equipment that I need to sell. Let me know if you are interested in any of the…See More
yesterday
Joe Quiroz Jr. liked Don Hynek's discussion Superinsulation retrofit is Complete!
yesterday
Mick Lane replied to Rob Buchanan's discussion High-use headscratcher
"The geothermal heat pump is the most likely culprit.  The heat pump doesn't make heat it…"
yesterday
Mick Lane is now a member of Home Energy Pros
yesterday
Empower Efficiency added 2 discussions to the group Job Board
yesterday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service