CAZ Testing

Views: 421

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Gary Baggett on February 19, 2011 at 5:18pm
Looks to me like that is a picture of CAZ testing...it's a combustable appliance. I do like the idea of CAST though. I'll ponder that one as I eat a grinder...
Comment by A. Tamasin Sterner on February 12, 2011 at 5:58am
Exactly.  My point is that we find teaching the entire combustion testing protocol to be more effective and easier for people to learn when we are specific about the test - what we are actually testing. 
Comment by Michael Dunseith on February 10, 2011 at 8:24pm

For thoses that need more infomation then a quick title...

 

The women in this picture is actually testing for ambient CO (Bugaboo for accuracy!) as well as spillage on a atmospheric Domestic hot water heater that is in a combustion appliance zone. Following BPI's combustion safety test procedure for vented appliances. (procedures number 3 and 5). Just a sample photo of some of the tests that are conducted in a CAZ! Here in the North east when someone states they are conducting CAZ testing, it just means that they will be performing all the tests required for that specific  appliance type. Without adding more acronyms to and industry that has too many already, we could start a new one combustion appliance safety testing (CAST).

This is a photo not a Q/A report,  lunch meat on bread is called sandwich, hero, grinder, hoagie, sub.

A picture says a thousand words - testing in a CAZ

Comment by A. Tamasin Sterner on February 10, 2011 at 7:20pm
Would love to influence the industry to stop using "CAZ Testing" when what they really mean, in the case of this photo, spillage testing.  CAZ means "combustion appliance zone" and really, all we really test regarding the CAZ itself is its relationship to the rest of the house and the outdoors, under normal (natural) and when we attempt to depressurize it the most (net worst case CAZ depressurization).  We call our testing by the name of the test:  ambient CO testing; undiluted flue gas testing for CO; draft pressure testing; spillage testing; combustible gas leak testing...  not "CAZ testing" unless we are talking specifically about the CAZ.  Just a thought!  Bugaboo for accuracy!
Comment by Michael Dunseith on December 5, 2010 at 1:48pm
The pitch here is about 1/2" per foot
Comment by Christian Asdal on December 2, 2010 at 9:50pm
the vent pipe appears to have inverse fall based on this picture....:)

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Amina Lang posted an event

19th International Passive House Conference at Congress Center Leipzig

April 17, 2015 at 9am to April 18, 2015 at 6pm
The Passive House Standard enables every building owner to benefit from the energy revolution, with…See More
30 minutes ago
Don Hynek replied to Luis Hernandez's discussion Non-continuous exterior insulation
"This is a matter of far more than R-values. Average exterior temp, heating load vs. cooling load,…"
16 hours ago
Patrick Michaelyan replied to Luis Hernandez's discussion Non-continuous exterior insulation
"Don, I'd like to ask you specifically about your comments on putting the structure at great…"
21 hours ago
Patrick Michaelyan replied to Casey Gesell's discussion Looking for home improvement companies to join our dealer network!
"Casey, Time frame for relocating is late spring to early summer. I am considering both counties…"
22 hours ago
Dennis Heidner replied to Patrick Michaelyan's discussion Vinyl Siding with Integral Insulation
"The observation about rot is important.   I agree. One of my complaints with some of the…"
Friday
Jennifer Schenk added a discussion to the group Job Board
Thumbnail

Job Opening - Energy Programs Manager - Frisco, CO

Energy Programs Manager - High Country Conservation CenterJob DescriptionGeneral Description of…See More
Friday
Jennifer Schenk joined Diane Chojnowski's group
Thumbnail

Job Board

This group is for posting jobs related to all aspects of the home performance industry including…See More
Friday
Avi Yashchin posted a status
""Will Online Learning Replace the Classroom?" Read my full article on HuffPost. http://huff.to/1cNCOie"
Friday

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service