Comment by Gary Baggett on February 19, 2011 at 5:18pm
Looks to me like that is a picture of CAZ testing...it's a combustable appliance. I do like the idea of CAST though. I'll ponder that one as I eat a grinder...
Comment by A. Tamasin Sterner on February 12, 2011 at 5:58am
Exactly.  My point is that we find teaching the entire combustion testing protocol to be more effective and easier for people to learn when we are specific about the test - what we are actually testing. 
Comment by Michael Dunseith on February 10, 2011 at 8:24pm

For thoses that need more infomation then a quick title...

 

The women in this picture is actually testing for ambient CO (Bugaboo for accuracy!) as well as spillage on a atmospheric Domestic hot water heater that is in a combustion appliance zone. Following BPI's combustion safety test procedure for vented appliances. (procedures number 3 and 5). Just a sample photo of some of the tests that are conducted in a CAZ! Here in the North east when someone states they are conducting CAZ testing, it just means that they will be performing all the tests required for that specific  appliance type. Without adding more acronyms to and industry that has too many already, we could start a new one combustion appliance safety testing (CAST).

This is a photo not a Q/A report,  lunch meat on bread is called sandwich, hero, grinder, hoagie, sub.

A picture says a thousand words - testing in a CAZ

Comment by A. Tamasin Sterner on February 10, 2011 at 7:20pm
Would love to influence the industry to stop using "CAZ Testing" when what they really mean, in the case of this photo, spillage testing.  CAZ means "combustion appliance zone" and really, all we really test regarding the CAZ itself is its relationship to the rest of the house and the outdoors, under normal (natural) and when we attempt to depressurize it the most (net worst case CAZ depressurization).  We call our testing by the name of the test:  ambient CO testing; undiluted flue gas testing for CO; draft pressure testing; spillage testing; combustible gas leak testing...  not "CAZ testing" unless we are talking specifically about the CAZ.  Just a thought!  Bugaboo for accuracy!
Comment by Michael Dunseith on December 5, 2010 at 1:48pm
The pitch here is about 1/2" per foot
Comment by Christian Asdal on December 2, 2010 at 9:50pm
the vent pipe appears to have inverse fall based on this picture....:)

Featured Forum Discussions

Lighting replacement - 300 watt LED flood light

Started by Mary Sinkler in General Forum. Last reply by Dennis Heidner 13 hours ago. 2 Replies

Glass Block Windows

Started by Ken Kalke in Best Practices. Last reply by Sean Lintow Sr on Saturday. 1 Reply

What's the Most Profitable HVAC Job for Your Company?

Started by Wayne Melancon in HVAC. Last reply by Ken Kalke on Friday. 1 Reply

EZ Green Home is Hiring!

Started by Chloe Chapman in General Forum Jan 5. 0 Replies

Videos

  • Add Videos
  • View All

Latest Activity

Horace Douglas Hunt, Jr. joined Tom White's group
Thumbnail

Weatherization

Share your concerns and successes as a weatherization professional, or information for this…See More
1 hour ago
Horace Douglas Hunt, Jr. joined Sean Lintow Sr's group
Thumbnail

Best Practices (Residential)

Best Building, Retrofitting, or even Auditing Practices - what are they, what should change, what…See More
1 hour ago
Horace Douglas Hunt, Jr. joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
1 hour ago
Dennis Heidner replied to Mary Sinkler's discussion Lighting replacement - 300 watt LED flood light
"Have you looked how much light you need in the backyard and where you need the light?  Often a…"
13 hours ago
Nate Adams liked tedkidd's discussion Home Performance is Failing - let's turn that around?
17 hours ago
Nate Adams replied to tedkidd's discussion Home Performance is Failing - let's turn that around?
"Ira, you're not alone. Here in Cleveland the gas company uses their own auditors, it killed…"
17 hours ago
Nate Adams replied to tedkidd's discussion Home Performance is Failing - let's turn that around?
"Website is finally up, albeit still imperfect. You can check out the very detailed case studies.…"
17 hours ago
Paul Mausteller liked Bruce Fillmore's photo
17 hours ago

Home Energy Pros

Welcome to Home Energy Pros – the unique digital community by and for those who work in the home energy performance arena.

Home Energy Pros was founded by the developers of Home Energy Saver Pro (supported by the U.S. Department of Energy) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network. Please honor our Guidelines

© 2017   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service