Looking at leaky can lights.

Leaky recessed-can lights were big energy wasters before they were sealed.

Views: 298

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Adam Zielinski on March 24, 2011 at 12:01pm

Sealing up a can light with a foam board box is a code violation and unsafe.  If you do it, you need to use a non combustible material, like drywall, or one of the tenmat mineral wood recessed light covers.  http://www.tenmat-us.com/

 

The Cree LR6 LED conversion kits are nice, and should cut down on air leakage.  However if you install them in a non-IC rated can light housing, you still are not supposed to put insulation over the top of them.  So you would still have to baffle around the can in the attic.   The best option for Non-IC can lights is to remove them and replace them with IC rated fixtures, or some other alternative lighting. 

 

Comment by Jim Gunshinan on January 24, 2011 at 2:42pm

Haven't heard of that Bob, thanks for the heads up!

 

Comment by Bob Small on January 20, 2011 at 3:04pm
Have you seen the Cree LR6 LED conversion? www.creeLLS.com Lets you switch to an LED bulb in a sealed unit that screws in to your existing can housing. Great price too.
Comment by Jim Gunshinan on December 20, 2010 at 10:55am

Sorry, that was five years ago when Larry wrote his article.

Comment by Jim Gunshinan on December 20, 2010 at 10:54am

Larry Armanda, who used to call himself the "Can Man" because he spent a lot of time looking at and fixing recessed can light leaks, wrote about it for Home Energy in 2005 "Further Wrestling with Recessed-Can Lights" (Sept/Oct). He didn't find a great retrofit kit, but Builders Best and Lithonia Lighting put out some good kits for sealing the can lights. That was ten years ago, so things may have changed.

 

At our house the contractors used a non-expanding spray foam to seal the lights where the fixture meets the ceiling. (The retrofit kits have a spongy gasket that does the same thing.) Then our contractor made boxes out of foam board to insulate the can-lights on the attic side. There was one problem—the can lights with incandescent lights stay on for about two hours and then the thermal cut off switch turns them off. The insulation makes the light fixture heat up rapidly inside. Without a thermal cutoff switch, the fire danger would be pretty serious. We put CFLs in the can-lights and fixed that problem. We need a brighter light in one room, over a desk, and still have an incandescent there. It cuts off after a few hours and I take it as a signal to get away from my desk for a while! They should be CFLs that give that kind of light but we haven't found it yet.

 

Hope this helps!

Comment by dale conner on December 20, 2010 at 7:36am

Do you know of a good kit for converting the leaky lights to sealed ones? I pulled my leaky lights out of my house and replaced them with sealed lights but only because I was able to access them via the attic space.

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Paul Raymer posted a blog post

Zonal Pressure Puzzle

I have a wonderful little (16 x 14 x 8) test cabin at Bristol Community College in Fall River, MA. …See More
5 hours ago
Sarah Holloway posted a blog post

Play Game of Homes, by EnergyLogic, Inc.

I'd like to introduce everyone to Game of Homes, our cutting edge scenario based training tool…See More
6 hours ago
Nate Adams replied to Rob Madden, Solar Home Broker's discussion Indoor Air Quality Monitors and Meters
"Rob, I've bought, borrowed, or been given a number of different monitors. I had an Air Advice…"
10 hours ago
tedkidd replied to Rob Madden, Solar Home Broker's discussion Indoor Air Quality Monitors and Meters
"Yep, steep price but you will learn a lot. We are hoping these new devices that homeowners can own…"
11 hours ago
tedkidd replied to Luis Hernandez's discussion ERV Configuration
"We don't recommend ERV's anymore. If you are in a green grass climate ventilating…"
11 hours ago
Home Energy Magazine's blog post was featured

Is the Perfect Wall Realistic?

Wrong question. The right…See More
12 hours ago
Chris Laumer-Giddens's blog post was featured

Building with Rocks, Rocks. Check out the Drying Potential

Building with Rocks, Rocks! Check out the Drying Potential.Check this out! This 24" x 48" x 2"…See More
12 hours ago
Dan McKee posted a blog post

Innovations for Heating and Cooling

Heating and cooling of indoor spaces is one of the major operations of modern households and…See More
17 hours ago

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service