An ingenius way to vent out your bathroom fan.

An ingenius way to vent out your bathroom fan.

Sometimes the things we see are mind-blowing.

Views: 981

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Jim Mikel on March 20, 2011 at 6:52pm

Jack, that is too funny!  I can only imagine how fast the blower door was turned off.  I had a similar situation where the owner had their dryer vent hooked up mutually with their bathroom fan (that the owner said did not work).  The only difference is that when the blower door turned on, lint was flying around that had been stuck in the bathroom vent!

Comment by Jack Baikoff on March 20, 2011 at 6:37pm
It's in Long Island, New York state. The owner did this himself after the installation of a bathroom fan. I've heard of at least one other instance of a bathroom fan being vented into a soil stack since I've taken this picture. There, when an auditor started the blower-door test the house filled with the stench coming from the bathroom fan.
Comment by Jim Mikel on March 19, 2011 at 7:44pm
Where was this?  In Missouri the building inspection codes are sooooo tough.  They would never allow it.
Comment by Eric Gribin on February 11, 2011 at 7:23am

What are they spending on air freshener?

Comment by Michael Dunseith on February 7, 2011 at 5:38pm

Mark,

BPI  requires that bath fans be vented outside.

No mention of soil stack pipes!

Kinda defeats the purpose of a bath fan to remove odors!

Comment by Mark Richardson on February 7, 2011 at 4:35pm

Yea, and the inside too!

wow...

Comment by Michael Dunseith on February 7, 2011 at 3:53pm
LOL, Thats a good one. Hose straight, no bends or Kinks. Love the duct tape. Cant make this stuff up.  I wonder what the program people would say? After all it is vented to the outside!

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Evan Mills replied to Sandra K. Adomatis, SRA's discussion Green Mortgage Appraisal Roundtable
"Would love see your slides, but the AI site requires login.  Can you post them here or email…"
2 hours ago
Colin Genge posted a blog post

What needs to be done to get builders to follow Code for duct and envelope leakage?

“Have you been ripped off for $100,000 by your builder?  Let us help you get what you paid for! …See More
8 hours ago
Green Training USA posted an event
Thumbnail

Proctor’s Without Borders at Online

July 29, 2015 to August 7, 2015
Complete your training at your own pace and take exams when you want and where you want. No…See More
17 hours ago
Gar Swaffar commented on Gar Swaffar's blog post Cost of using a BPI QCI?
"Ip.s., I would presume there will be a difference between the Left Coast and nearly everywhere else."
yesterday
Gar Swaffar posted a blog post

Cost of using a BPI QCI?

I'd like to find out if there is a consensus on a rule of thumb cost of a QCI onsite for…See More
yesterday
Gar Swaffar is now a member of Home Energy Pros
yesterday
Colin Genge posted an event

Infiltration and Duct Leakage with BPI at Online

July 30, 2015 from 1pm to 2pm
Blower door and duct test requirementsCalculating resultsCertification optionsTest preparation and…See More
yesterday
Stacy Hunt posted an event

Volunteers needed for the upcoming U.S. Department of Energy Solar Decathlon in Irvine, CA at Orange County Great Park

October 8, 2015 at 11am to October 18, 2015 at 7pm
Volunteer for the upcoming U.S. Department of Energy Solar Decathlon 2015, taking place Oct. 8-18…See More
yesterday

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service