Comment by Gary Baggett on February 7, 2011 at 6:05pm
Jack, I added some pics for you
Comment by Gary Baggett on February 7, 2011 at 5:53pm
lol...I didn't want to say that...I actually have a better picture of this somewhere. I should post a few on my "page"
Comment by Jack Baikoff on February 7, 2011 at 5:50pm
Yeah, thanks, sorry I did not notice it had an ambient CO display.
Comment by Gary Baggett on February 7, 2011 at 4:30pm
no, that was the co in the flu gases...which 400 constitutes an "emergency"
Comment by Jack Baikoff on February 7, 2011 at 4:25pm
OMG! What was the ambient CO reading?
Comment by Gary Baggett on February 7, 2011 at 12:44pm
Hey...I know where that picture came from...
Comment by Michael Dunseith on December 27, 2010 at 2:56pm
A friend of mind shared this with me the other day. I don't recommend keeping your very expense testing equipment in the flue any longer then need be.   Once you determined that the CO is excessive, does it really matter if its 500 ppm or more?  Note the efficiency!

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Eve Dunham replied to Kim Tanner's discussion Facebook page targeting and privacy in the group Marketing Energy Efficiency
"I have used the targeted ads feature for age, location, etc. I have had moderate success with this.…"
1 hour ago
Home Energy Magazine's blog post was featured
19 hours ago
Hannah Finch posted a blog post
19 hours ago
Profile Iconpank and Carrie Sturrock joined Home Energy Pros
20 hours ago
tedkidd commented on Amber Vignieri's blog post Chicago Winter No Match for Retrofitted Logan Square Building
"This case study is an example of how hard it is simply to do a compelling case study. Everyone has…"
22 hours ago
B. M. Lubin posted an event
Thumbnail

GPRO Construction Management Class at USGBC-LI headquarters in Hauppauge, NY at USGBC-LI Headquarters

September 19, 2016 at 9am to September 20, 2016 at 2pm
Taught by industry experts using real-life classroom exercises, GPRO CM gives experienced building…See More
yesterday
B. M. Lubin is now a member of Home Energy Pros
yesterday
Eric Kjelshus replied to tedkidd's discussion Dear DOE, PACE sucks - please fix or make it go away...
"Most HVAC system upgrade - change outs and attic seals-R-49 end up $20-30K   Most house -…"