sealed soffits near fan exhaust

sealing some soffits to fix ice damming

Comment

You need to be a member of Home Energy Pros to add comments!

Join Home Energy Pros

Comment by Adin Maynard on July 30, 2011 at 4:47am
Bryce, thanks for the comment. Yes the flat was fully airsealed and brought up to R-60 with cellulose.  Each standard chute vent was improved, as can be seen in far left bay in image above. The few soffits near the bath fan were sealed to prevent exhaust air from bring brought back into the attic.  THere was plenty of 'low/high' ventilation, so this approach was taken. 
This past winter was crazy for ice damming. As a result, for attic retrofits, we are careful to improve and maintain soffit vents whenever possible.
Comment by Bryce Cramer on July 29, 2011 at 10:52am
Not sure if I understand how sealing the flow of air through the soffit will reduce ice damns. The better approach would be to stop the heat loss through the attic floor with a better insulation job. Then provide proper ventilation so that the roof deck remains cold and does not therefore melt snow that refreezes over a cold soffit. If the bathroom vent is just vented into the soffit area, I would think this would cause additional issues. The warm air (moist) air will hang inside the soffit area since the soffit is now sealed from the rest of the atiic....this should lead to moisture, mold and other problems in the roof deck above this soffit area.

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Kent Mitchell commented on Adam Swain's blog post Top Worst Crawl Space Insulation Ideas
"Hi Adam - It sounds like you may be referring to enclosed crawlspaces - Here in the NW we've…"
1 hour ago
peter chang replied to Damien Greenfield's discussion Is there is cost saving for you in having a tankless water heater?
"I think it is quite possible the greatest savings will be realized by the lowest volume users. I…"
1 hour ago
Marie Fuentes is now a member of Home Energy Pros
1 hour ago
peter chang replied to peter chang's discussion Programmable tstat for electric baseboard?
"Good plan, thanks. That looks pretty much like how I used to program mine (when I had one). Maybe…"
2 hours ago
Bob Blanchette replied to peter chang's discussion Programmable tstat for electric baseboard?
"Since the sun heats the house to 78f during the day, cutting the power from the time you leave for…"
4 hours ago
peter chang replied to peter chang's discussion Programmable tstat for electric baseboard?
"Yes, in fact I did just that for my kitchen toe-kick heater because the original thermostat was on…"
11 hours ago
Bob Blanchette replied to peter chang's discussion Programmable tstat for electric baseboard?
"Savings depends a LOT on how it's programmed. I've even done a setup with a contactor,…"
17 hours ago
Bob Blanchette replied to Hal Skinner's discussion Any success getting landlords to energy upgrade a single family rental unit?
"Sell utility subsidized services to the tenants. It has to pay back within a year though."
18 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service