Can you trust your Load Calc Software? 1 Reply

Attention Wrightsoft Users!  Have you ever completed a load calculation and it just seems like it was short of what you had expected?  Particularly when you are first starting out with a tool,…Continue

Started by Christopher Morin. Last reply by Eric Kjelshus Feb 18.

Attic insulation vs. Insulated roof deck 3 Replies

Can anyone tell me how Wrtightsoft treat a a insulated roof deck compared to a insulated flat attic.Continue

Started by Robert DV. Last reply by Robert DV Jul 6, 2012.

How Manual-J's Can Lead to Under-Sized Ducts

It difficult to imagine something bad happening as a result of doing something we feel is so good. But here's what is bound to happen, at least a few times...A manual-j load calculation is produced…Continue

Tags: sizing, duct, manual-j

Started by Isaac Savage Jul 6, 2012.

Support licensing in 2011 2 Replies

I previously purchased a license for Wrightsoft. Now that they have gone to an annual support fee in 2011, they won't even give me a new license key when I reloaded the software on the same machine…Continue

Tags: fees, license, WrightSoft

Started by Robert Zockoff. Last reply by Robert Zockoff Jun 20, 2011.

Comment Wall

Comment

You need to be a member of Wrightsoft - Manual J / Manual D to add comments!

Comment by Kristof Irwin on May 10, 2012 at 12:08pm

Anyone else have consistent issues when trying to transfer user license from one computer to another? Any tips? First computer registers removing the license. Then the second says it is still installed on previous computer. Getting a hold of tech support is always a long process - usually about an hour on hold (!?). 

Comment by dale conner on March 26, 2012 at 4:42pm

Besides a laptop computer what do you guys use ? ipad?

Comment by Steven Lewis on May 23, 2011 at 9:38am
Thank you
Comment by Steven Lewis on May 23, 2011 at 8:21am

I am having a SR Moment -

 To remove a room from the load calcs you do two things.  One is to select "NO" as to include the room in the calculations  but I cannot remember the second item/place to actually have the room excluded ffrom the calculation. 

 

I dont exclude rooms that often and as my father told me" Memory is the second thing to go and I don't remember what the first was"

 

Members (39)

 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Profile IconKevin Jordan, Hannah Strong, Rich Snyder and 1 more joined Home Energy Pros
5 hours ago
EnergyLogic Academy posted events
5 hours ago
EnergyLogic Academy updated an event
Thumbnail

RESCAZ- RESNET Combustion Safety Testing: North Carolina at Wilmington, NC

November 7, 2014 from 6pm to 7pm
The health and safety of the home energy auditor’s clients should be the top priority when…See More
5 hours ago
EnergyLogic Academy updated an event
Thumbnail

RESNET Phase 2 Rater Training - Field Training at EnergyLogic Academy - Berthoud CO

September 22, 2014 to September 24, 2014
The EnergyLogic Academy will be hosting the second phase of HERS Rater Training August 4th - 7th,…See More
5 hours ago
Hal Skinner replied to Scott Katznelson's discussion Database of zip code or county by climate zone
"Hi Scott. I dont know of a database that you are referring to.  I was always under the…"
6 hours ago
Rich Snyder joined Rich Brunco's group
Thumbnail

Cape Cod Energy Pros

Recent BPI classmates, a place to share referals and informationSee More
7 hours ago
Scott Katznelson posted a discussion

Database of zip code or county by climate zone

HI.  I'm looking for a database that could help me assess the average energy use of a home (per…See More
13 hours ago
Hal Skinner replied to Hal Skinner's discussion The 'Touchy - Feely' sales pitch. in the group Radiant Control Coatings
"The 2nd bestsales tool I ever came up with.  aI will be happy to send anyone a test strip like…"
19 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service