Looking for Trainers in the Northeast

I'm looking for a trainer or two who would be willing to come in and train for BA and EP courses in CT. Please email me concerning details at gbaggett@usgbd.com or call my office at 203-296-2207Continue

Started by Gary Baggett Feb 14.

2013 Manual-S Speedsheet Now Available

Hello Trainers,You're invited to check out the latest and greatest Manual-S Speedsheet.It actually HELPS…Continue

Tags: design, HVAC, ACCA, Speedsheet, Manual-S

Started by Isaac Savage Apr 7, 2013.

Protecting presentations 5 Replies

PowerPoint presentations take hours to create - about an hour a slide, I have found.  When I am asked to put on a training session these days or make a presentation at a conference, I am essentially…Continue

Tags: presentations, Powerpoint

Started by Paul Raymer. Last reply by Tom Conlon Nov 1, 2012.

Conflict Resolution 7 Replies

I'm currently training in Washington, DC and one of the grants my organization has involves training individuals with non-violent criminal backgrounds recently released from incarceration in the…Continue

Started by Chase Counts. Last reply by Rodney Purnell Oct 17, 2012.

Request your feedback on the new BPI WHALCI certification training 10 Replies

My training center is presently training the new BPI installer certification.Is anyone else training this course? What is your impression? Have you developed your own curriculum or are you using…Continue

Started by Matthew Redmond. Last reply by Debra Monte Mar 15, 2012.

Mentors, What Serves As a "Compass"? 1 Reply

Engagement with people in process can lead into fog, quicksand, smoke and other urgencies and uncertainties. Assuming that mentors are made, not born, what do you recommend as preparation and/or…Continue

Tags: process, human being, people, engagement

Started by David Eggleton. Last reply by David Eggleton Aug 31, 2011.

Commercial Energy Services---Commercial Audit Training? 6 Replies

Hi.I am a residential energy auditor. Does anyone know where Commercial Energy Audit training is offered? I have seen some online commercial audit training.  Is this reputable training?…Continue

Started by Donna Sanders. Last reply by Donna Sanders Jul 5, 2011.

ACI's National Trainer's Conference

Wanted to make sure you all knew that ACI is hosting a Trainer's conference in Charlotte, NC in November. We are confirming the agenda and looking forward to something great. Who Should…Continue

Tags: energy, home, trainer, conference, trainers

Started by Jennifer Luitwieler Jun 22, 2011.

Training Materials and Resources 5 Replies

The resources, whether they be PowerPoint files, videos, or anything else, that trainers are using seems to come from all over the map. Some trainers and training organizations are working with truly…Continue

Tags: curriculum, training

Started by Graeme Nix. Last reply by Silvie Votrubova Mar 21, 2011.

Comment Wall

Comment

You need to be a member of Trainers and Mentors to add comments!

Comment by Judi Lyall on May 30, 2013 at 5:36pm

Hi Folks,

   I have decided to retire and hopefully some lucky person will be able to take advantage of the tools I have. I bought these tools 2 years ago brand new.

1. ENERGY CONSERVATORY BLOWER DOOR W/ DG700 W/ USB PORT AND XTRA HOSE KIT, PADDED CASE                                                                                         2400.00

2. ENERGY CONSERVATORY DUCT BLASTER W/ DG700 W/ USB PORT                                                                                                         1500.00

3. ENERGY CONSERVATORY LARGE AND SMALL RESSURE PANS  150.00

4. FLUKE TiR INFARED CAMERA EXTRAS INCLUDE CAR CHARGER AND SUNSHEILD                                                                                              3600.00

5. TSI ACCU BALANCE MODEL 8371                                                      2700.00

6. 20 PC ZIP POLES AND DUC BLOCS                                                   1500.00

7.BACHARACH FYRITE TECH 60 COMBUSTION ANALYZER                400.00

8. BACHARACH INFORMANT 2 LEAK DETECTOR W/ RUBBER CASING AND FLASHLIGHT HOLDER                                                                              300.00

9. INSULATION GRABBER                                                                           45.00

10. 2 3/8" TELESCOPING LED LIGHT, INSPECTION MIRROR                  10.00

THAT'S ALL FOLKS

EMAIL ME JUDI@SHEBUILDSGREEN OR CALL 818.625.0987

THANKS FOR READING AND CONSIDERING.

Comment by Stephen Smith on March 15, 2012 at 2:28pm

Just from the BPI group, lots of talk about the new 4 certifacations.... Any ideas on how BPI intends to test for these when we have no trainers/proctors for these?  As of yet, there is no real info on what will be needed for these other than if you have H.S. education, clean record and years of experiance in the construction/energy industries.

Comment by Mahendra Shah on January 6, 2011 at 5:54pm

 

Program Director GoingEvergreen

GoingEvergreen.org

 

Bringing Business, Schools, colleges, and Community together to

define, deploy, train, mentor High School and Tech Graduates to become Green Energy Technologist, Professional with program and projects based learning.. Achieve Virtual Green Energy application goals.

 

Comment by Rick Williams on January 4, 2011 at 12:53pm
Good day.  I have been providing the How To Finance Energy Upgrades for the CBPCA since August.    Despite the loss of PACE, there are many good financing options available.   The new PowerSaver Pilot from FHA will become available in March and will offer 50% up front funding and low interest rates.   Our challenge is to provide additonal value in the home.  Any comments are welcome
Comment by A. Tamasin Sterner on December 8, 2010 at 2:53am
Thanks, Dale. Curious - have you compared draft pressure measurements using the three different probes/tubes you mentioned? It would be interesting to see the data.
Comment by Dale Sherman on December 7, 2010 at 7:59pm
Hey, Paul and Tamasin. Dwyer Instruments has some nice info on measuring low velocity static pressure (draft). Straight in is the best way to measure the low velocity airflow in a stack. An 'L' shape would be better for measuring duct velocities, but a regular 'L' shaped pitot tube will also work for measuring the static pressure, just ignore the velocity pressure port on a pitot tube.
Comment by A. Tamasin Sterner on December 7, 2010 at 2:54pm
Thanks Tom for reminding me to register The Pure Energy Center on the HE Guide to Training Programs!
Comment by A. Tamasin Sterner on December 7, 2010 at 2:53pm
Oh, Paul, you are my idol! We have done some research on which probes to use to measure draft pressure because we found different pressures with the two different probes while testing the same appliance... We started out using the static pressure probe tips. Then we moved to straight probes and found inconsistent results. We've decided to always use the static pressure probe tips. And, because we do QA and QC (Final Inspections) after work is complete, we have the responsibility to be as or MORE accurate than the contractors (because we have the power to fail jobs). If our probe measures low draft pressure and the contractor's probe measured a stronger draft, we might fail a job for inadequate draft pressure. This isn't OK if we aren't using the correct probe. So we use the static pressure probe tips.

We didn't know about the warranty void for drilling holes in draft diverters. At least we fill the holes with chrome hole plugs (at a buck a piece!).
Comment by Paul Raymer on December 5, 2010 at 8:58am
Drilling draft diverters
There are some You Tube videos and other training programs that promote drilling the draft diverter in order to access the undiluted CO more easily. It is my understanding that doing so will void the warranty on the water heater and that it is better to use an 'L' shaped adapter to reach the undiluted flue gases.

I also think we should arrive at consensus on whether or not using a straight tube or 'L' shaped static pressure probe is the right way to measure draft. Seems like the straight tubes go into the flue at a variety of angles and inconsistent depths.
Comment by A. Tamasin Sterner on November 24, 2010 at 6:40pm
Howdee, Friends! Pure Energy is opening a training center called The Pure Energy Center near Lavina Montana. Yep, in the middle of nowhere! Check out www.PureEnergyCenter.org.
 

Members (122)

 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Kurt Shafer replied to Tom Conlon's discussion Whole House Fans - Love 'Em or Not?
"Graham, what "large fan" are you referring to?  I am fascinated by your comment…"
5 hours ago
Profile IconTom Mallard, Eugene Swier and 2 other members joined Hal Skinner's group
Thumbnail

Radiant Control Coatings

A group where people who work with radiant barrier coatings can let others know all of their uses.See More
6 hours ago
Graham Irwin replied to Tom Conlon's discussion Whole House Fans - Love 'Em or Not?
"I think it is important to check the energy consumption of such a large fan, even assuming it can…"
7 hours ago
Hal Skinner added a discussion to the group Radiant Control Coatings
Thumbnail

Rooftop A/C units and exposed ductwork

Lets start a discussion about rooftop A/C units and exposed ductwork. The worst place to put a…See More
8 hours ago
Richard Beyer posted discussions
8 hours ago
Brandon Walton replied to Brandon Walton's discussion EFAZ and APS Hosting Huge Welcome Party!!
8 hours ago
Brandon Walton shared their discussion on Facebook
8 hours ago
Brandon Walton posted a discussion

EFAZ and APS Hosting Huge Welcome Party!!

If your in Arizona on August 20th, stop on by and check it out!APS Home Performance Program Q&A…See More
8 hours ago
Brandon Walton posted an event

Efficiency First AZ is Hosting Huge Meeting August 20th! at Rennick's Restaurant in the Hilton Phoenix Airport Hotel

August 20, 2014 from 5:30pm to 7pm
APS Home Performance Program Q&A w/new leader Maggie Gibbs!Join Efficiency First Arizona (EFAZ)…See More
8 hours ago
Dennis Heidner replied to Jamie Kaye's discussion Flickering LED lights
""CFLs produce light by using electricity to instigate a chemical recation between mercury…"
10 hours ago
Richard Beyer joined Michael Stuart's group
Thumbnail

INFRARED THERMOGRAPHY USERS

This group is dedicated to knowledge sharing and discussion of infrared thermography for building…See More
10 hours ago
Profile IconTomás León, Tauran Ivall, Alex Burnham and 1 more joined Home Energy Pros
10 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service