Information

Tools of the Trade

A hammer and a saw used to be the key tools for home contractors. Today, the best-in-breed also use high-tech equipment while performing a professional energy audit or verifying that construction has been done correctly.

Members: 103
Latest Activity: Apr 10

Add Tools to the Tools of the Trade Page

Add tools to the Tools of the Trade page by starting a new discussion. Click + Start Discussion in the Discussion Forum below to post.

Discussion Forum

Seeking a Flow Hood

Started by George Matthews Apr 10. 0 Replies

Affordable Manometers?

Started by Isaac Savage. Last reply by Pete Stoermer Feb 15, 2016. 3 Replies

Looking For A Retrotech Duct Tester ?

Started by Chris Schiewer. Last reply by Jamie Kaye Dec 16, 2015. 1 Reply

Buying Used Equipment

Started by Nick Semon May 18, 2015. 0 Replies

Used Blower Doors?

Started by Isaac Savage. Last reply by Cameron Millard Jan 16, 2014. 3 Replies

Instant read thermometers

Started by Ryan Moore. Last reply by David Meiland Apr 29, 2013. 3 Replies

Good Place to Compare Appliances?

Started by Donna Sanders Jan 12, 2013. 0 Replies

Smoke puffers

Started by Paul Raymer. Last reply by Jim Gunshinan Mar 15, 2012. 8 Replies

CO Testing for BPI

Started by Paul Raymer. Last reply by Chris Stratton Mar 2, 2012. 6 Replies

Comment Wall

Comment

You need to be a member of Tools of the Trade to add comments!

Comment by A. Tamasin Sterner on February 10, 2011 at 7:33pm
Ladies and Gentlemen, I have to tell ya, I'm a HUGE fan of flexible probes!  Love my flexible probe for my Testo 327 - NO more drilling!! and, the flexible, lighted probe on my video boroscope is awesome!  Today, I saw what was happening under a dryer - solved a combustion air issue by cleaning!
Comment by Graeme Nix on December 28, 2010 at 2:03pm

Ron, Paul,

First, the flow rings are always attached on the inlet side of the fan, regardless of whether you pressurizing or depressurizing. Admittedly, this does make it less convenient to change the rings if that becomes needed, since you'll have to remove the flex duct first.

The ability to test in either direction, however, is a key feature of the Retrotec DucTester. It is true, Ron, that if the grill mask holds tight, there should be very little difference in the results between depressurization and pressurization, however, the possibility does exist that if it's not properly secured, the grill mask can be pushed off a register, leading to faulty results, or a repeated test. Hence our recommendation. However, it must be clearly said that if there's a risk of polluted, dusty, or mouldy air being pulled into the house, the ducts do not need to be depressurized.

Comment by A. Tamasin Sterner on December 24, 2010 at 11:39am
We are using flexible probes for our combustion analyzers.  Great solution for checking undiluted flue gasses for CO content.  Instead of drilling holes in draft diverters in order to get the probe into the undiluted gasses, we use flexible probe.  Check out the photos I've uploaded.
Comment by Evan Mills on December 16, 2010 at 11:41pm

Some discussion over here on choosing IR cameras and blower doors.

Comment by Ron Jones on December 12, 2010 at 6:02pm

Thanks for that.  I've been curios since you raised the topic if there would be a difference.  I'll try it some time with my Energy Conservatory Duct Blaster and if I see anything funny I'll let you know.

Comment by Paul Raymer on December 11, 2010 at 8:05am

Ron -  As far as running the Retrotec duct tester either way, after your question, I was teaching a class yesterday, and we ran the duct tester both ways and got exactly the same result.  It was extremely handy to be able to leave the blower door installed to quickly do the Total Pressure and then the Pressure to outside.  (The ducts in the building I was testing were awful to say the least.  Even the theatrical smoke was diluted to the extent that it was hard to see.)

Comment by Paul Raymer on December 11, 2010 at 8:02am

Tamasin -

I have been using a Motion Computing J3500 for auditing.  It's built for field work with "Gorilla" glass and a solid state drive.  It is not cheap, but it's incredibly fast and extremely bright even in direct sunlight.  It takes a little getting used to - carrying this amazing machine in an attic or crawl space.  It takes pictures and even can serve as a telephone.

I have been playing with HomeGauge software.  It is designed primarily for Home Inspectors, but it does have an energy template.  I am working with them to refine the output, but it has a spreadsheet for BPI combustion safety testing, etc.  I like the idea that it is on my computer and I don't have to pay annual fees or individual use fees or any other fees.  I haven't done it yet, but they can take your data on-line so that your clients can download it.  It's really easy to add pictures and they have an enormous bucket full of pre-written comments like warnings about windows not being the first step in saving energy.  It does figure area weighted R values and the BAS as well.

The first report I did was about 35 pages long, which is very fancy, but too much information for the average homeowner.

Comment by A. Tamasin Sterner on December 10, 2010 at 5:28pm

Is anyone using Tablets for auditing? If so, what are you using and what software?  Do you like it?

Comment by Ron Jones on December 8, 2010 at 6:33pm
I don't think Retrotec's argument holds much water. Have they tested a hundred house systems both ways, pressurized and then depressurized, and measured the difference? I can't imagine it would be enough to impact my recommendations to a homeowner. I'm not giving you a hard time, it's just that this is the first time I've heard depressurizing ducts suggested, so the possibilities are intriguing. Have you done it?
Comment by Paul Raymer on December 8, 2010 at 6:53am
That certainly may happen. Retrotec advises depressurizing so that the duct masks are pulled more tightly against the grilles rather than being pushed off. Also, if a "Leakage to Outside" test is going to be done using the blower door, the blower door fan doesn't have to be turned around to blow air into the house. And if it is a cold winter day, blowing 25 Pa of outside air into the house may be more detrimental than some leakage from the crawl space.
 

Members (103)

 
 
 

Discussion Forum

Seeking a Flow Hood

Started by George Matthews Apr 10. 0 Replies

Affordable Manometers?

Started by Isaac Savage. Last reply by Pete Stoermer Feb 15, 2016. 3 Replies

Looking For A Retrotech Duct Tester ?

Started by Chris Schiewer. Last reply by Jamie Kaye Dec 16, 2015. 1 Reply

Buying Used Equipment

Started by Nick Semon May 18, 2015. 0 Replies

Used Blower Doors?

Started by Isaac Savage. Last reply by Cameron Millard Jan 16, 2014. 3 Replies

Videos

  • Add Videos
  • View All

Latest Activity

Chris Woods added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

Minneapolis Blower Door Fan and Door frame $990 OBO

I have a used Minneapolis blower door fan (fan only, no controls or panel) and the blower door…See More
2 hours ago
Profile IconManuela L Heyn and Paul Nagel joined Home Energy Pros
5 hours ago
Bill Spohn replied to Eric Sperline's discussion Wanted: Energy Auditing Equipment for sale in the group Energy Auditing Equipment for Sale, Trade or to Purchase
"If you choose to buy new, give TruTech at call at 1-888-224-3437 option 1"
8 hours ago
Home Energy Magazine's blog post was featured

The Legends of Home Performance

A project long in the making, we're happy to finally reveal some of our Legends of Home Performance…See More
9 hours ago
Quinn Korzeniecki replied to Larry R Waters's discussion BPI Anaylist
"Hi Larry, We're glad you're reaching out to hire some BPI folks! You can also submit…"
12 hours ago
Larry R Waters posted a discussion

BPI Anaylist

Industry leader in the north bay area California. Looking for experienced professionals and future…See More
19 hours ago
Larry R Waters joined Diane Chojnowski's group
Thumbnail

Job Board

This group is for posting jobs related to all aspects of the home performance industry including…See More
20 hours ago
John Nicholas replied to Jim Fowler's discussion TREAT modeling of mid-rise apartments low heating load
"So why is tenant behavior significantly different in this building?"
21 hours ago

Home Energy Pros

Welcome to Home Energy Pros – the unique digital community by and for those who work in the home energy performance arena.

Home Energy Pros was founded by the developers of Home Energy Saver Pro (supported by the U.S. Department of Energy) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network. Please honor our Guidelines

© 2017   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service