INFRARED THERMOGRAPHY USERS

Information

INFRARED THERMOGRAPHY USERS

This group is dedicated to knowledge sharing and discussion of infrared thermography for building sciences and energy applications.

Members: 152
Latest Activity: yesterday

Discussion Forum

Google Thermal View? 1 Reply

As most of you know, there is more to an energy audit or energy rating (such as a HERS rating) than just the thermal imaging - but this start up company is using it to get a nationwide database going.........Here's a link to the article on…Continue

Tags: Audit, business, Energy, Google, imaging

Started by Joshua Knittel. Last reply by Nick Helmholdt yesterday.

Infrared Image - What is it? 6 Replies

We thought it'd be fit to share this infrared image we received from group member, CK Ang, in New Zealand. Just wanted to spark some discussion here on what you guys think this image is of, and what the problem could be. A little background on the…Continue

Tags: Fluke, Ti55FT, telephoto, lens, Ang

Started by Fluke Thermal Imaging. Last reply by Dale Sherman Apr 26, 2012.

Timber Home with no effective air barrier 1 Reply

Hi folks,just another image of a brand new timber home without an effective air barrier, and without sealing tapes.…Continue

Started by Davide Lanzoni. Last reply by Sean Lintow Sr Apr 11, 2012.

New article on infrared thermography 1 Reply

The Journal of Light Construction has long been respected as a place where builders can educate themselves and share information. I was recently asked to write an article introducing their readers to thermography and how it can be used in the…Continue

Started by John Snell. Last reply by Jim Klebes Nov 17, 2011.

Moisture detection, a fascinating thermal signature

I don't mean to derail folks from this website to ours (I often send folks here too!) but that is exactly what I'm going to do because www.IRTalk.com has a fascinating discussion about thermal signatures of…Continue

Started by John Snell Sep 9, 2011.

New York first passivhaus ... 4 Replies

... with windows with a better R-value than walls ?…Continue

Started by Davide Lanzoni. Last reply by John Snell Aug 25, 2011.

Using thermal imagers in the summer 5 Replies

Too many thermographers leave their imagers in the case during the summer. This comes, in part, from the way we used to work when imagers were not nearly as sensitive and our understanding of how to use them was limited to winter work.Get the darned…Continue

Started by John Snell. Last reply by Tyson Pischel Jul 7, 2011.

Expert Eye Needed 15 Replies

Hi AllWanted to get the opinion of an expert.Attached is a photo of a customer's window.... as you can see there is a large cold spot above the window... Here's my opinion..am I right?The large horizontal cold spot is thermal bridging from the…Continue

Tags: windows, ir

Started by Matthew P. Last reply by Ed Minch Jun 30, 2011.

IR and Moisture Meters 12 Replies

As many of you know the new RESNET Guidelines are being worked on and I am advocating for the use of Moisture Meters to ensure potential serious moisture problems in sidewalls and building substrate material is not being overlooked when identified…Continue

Started by Bret Monroe. Last reply by allen p tanner Jun 23, 2011.

Certification for RESNET Thermographers 12 Replies

I’m just back from the RESNET national conference in Orlando and I am very excited to report that RESNET certification is now available! What’s needed?• You must be a RESNET Building Performance Auditor or a Rater• You must have 3 months experience…Continue

Started by John Snell. Last reply by Mark Cleminson Mar 22, 2011.

Comment Wall

Comment

You need to be a member of INFRARED THERMOGRAPHY USERS to add comments!

Comment by Joshua Knittel on May 21, 2012 at 4:46am

As most of you know, there is more to an energy audit or energy rating (such as a HERS rating) than just the thermal imaging - but this start up company has a good idea on how to get a nationwide database going.....

Here's a link to the Treehugger article:

http://www.treehugger.com/clean-technology/startup-takes-google-str...

Comment by John Snell on May 26, 2011 at 5:09pm
No, despite what some suggest, it is not a simple process to determine R-value or otherwise quantify heat transfer based on a single thermal image. Still, images can be very compelling and other tests can fill in the numbers.
Comment by Hal Skinner on May 26, 2011 at 5:02pm

That was what I had somewhat envisioned for that test.

 

One room in a home.  Half the wall painted with the coating and half with regular paint and thermal picture from the outside to show the heat energy reduction.

 

The 2nd test would be painting the coating on a section of a wall and regular paint on the EXTERIOR wall, again both on the same wall of a room - half and half, to show the reduction.

 

What I am most curious to see is if what it shows on the thermal picture can be measured in some form.  Or, is that going to require other measuring equipment to determine exactly what % of reduction we are looking at in the thermal picture.

 

What radiation / heat energy they see on one half vs what they see on the other.  Can a thermal inage akone determine that?

Comment by John Snell on May 26, 2011 at 4:50pm

Hal, One of the issues you run right into using thermography to show the impact of insulating coatings is that the imagers SEE radiation. Thus if the coating reflects radiation in the wavelengths detected by the imager, you'll see that but that doesn't necessarily show how effective the coating is. Better to paint some of the interior wall surfaces and leave others unpainted and then look at the wall from the exterior; of course this assumes all walls are same construction (except the coating) and that all thermal influences on both sides of the wall are similar. 

I know some folks have tried this sort of test but I'm not convinced they "dotted all their i's and crossed all their t's" if you know what I mean.

It might be more effective to design a demonstration on a smaller scale, say a couple of cardboard boxes with the same internal heat source. If the coating actually reduced heat transfer, it would show up on the exterior side. John N. is correct, however, in that most people would not accept a couple of cardboard boxes as good science!

Comment by John Nicholas on May 26, 2011 at 9:04am

Hal,

 

If you set it up so you could follow a standardized testing protocol, such as RESNET, ANSI, or ASTM perhaps you could make a claim.  Would your claim be accepted by the building performance industry?  Some would, some wouldn't.

 

Your best bet to establish a insulative value for any product claiming to retard heat transfer is to pay an independent lab to do a guarded hot box test on it.  That will actually measure the heat loss per sf in each sample.  The test is repeatable, and is not subject to interpretation.  With this independent test, you can get DOE, RESNET, BPI and other entities that are recognized within the industry to use the information.

Comment by Hal Skinner on May 26, 2011 at 7:57am

Hi Michael.

 

I have a question;  How exact a science is thermal imaging?  I have many years working with an insulating coating but ZERO experiences with thermal imaging.

 

Hypothetical situation;  If we painted an insulating coating on the interior sheetrock of a home, say we painted half a wall, I would expect a themal image showing a reduction in the loss of heat through that wall to the outside colder air.

 

Is thermal imaging an exact enough science so that those images can be analyzed to determine the exact amount of heat loss reduced and thereby calculate it's equivolent R-rating? 

 

Thanks and my apologies if this sounds like a dumb question.

Comment by Michael Stuart on February 3, 2011 at 4:14pm
I apologize that I have not posted anything interesting the group lately... but I have been a busy guy!   However, I attended ACI Northwest this week down in Portland, Oregon and had a great time.   On Monday of this week, I had an opportunity to perform a fun infrared inspection and blower door test with some other colleagues on a south Portland home.   I will share some of the images as soon as I get a chance to get them out of my Ti32 imager.  I also strongly encourage all other members of this group to post examples of your work, ask questions, and prod us into meaningful discussions.
Comment by Michael Stuart on December 23, 2010 at 10:19am

Happy Holidays to all on HEP!  May all of your season's wishes come true!  And may we all have a prosperous New Year!

Comment by Michael Stuart on December 13, 2010 at 1:42pm

TJ,

 

Thanks for the follow up with all of us.   Interesting developments.  Thanks for the added images as well.

Comment by TJ Ewing on December 12, 2010 at 7:43pm

Hi all,

Sorry it took me so long to update, I’ve been in a mad dash to the holidays!  So we did take the bulletin board off (which showed evidence of wetting/rot on its backside) and the church reps were more than eager to do a destructive core given the many decades of trouble with this wall. So they did! We learned we have 4" block with at most a 1/2" air gap to the brick that is most likely impeded in many places by mortar. No vapor or air barrier present and no block insulation or filling.  We saw no direct evidence of internal wall moisture. There's been a lot of confusion by the church reps on when the wetness appears. But at this point we have an externally concentrated drainage area of a large portion of roof, potential irrigation spray onto the brick during summer, less than adequate drainage away from the external side of the brick veneer wall, a weak drainage plane, no weeps in the wall, and some contact between the brick and concrete. Controlling water sources is primary in our minds as we think the wall is wicking bulk moisture via the wall surface and from the ground. When the morning sun hits the SE facing wall, it drives the moisture in which condenses underneath the interior wall paint. The church is replacing the bulletin board with standoffs and we are leaving our core hole open for now.  We aim to control moisture first, and when the event happens again, take more details of the internal and external conditions when it does.

Have a great holiday season,
TJ 

 



 

Members (152)

 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy, under the American Recovery and Reinvestment Act) and brought to you in partnership with Home Energy magazine.

Latest Activity

Dennis Heidner replied to Jose Macho's discussion Why Are Energy-Saving Home Inprovements Down??
"Ben,  the German highway system concept actually started BEFORE Nazi Germany during  the…"
7 hours ago
Stan Kuhn replied to Patrick Michaelyan's discussion Hot Upper Stories
"You note overheating on the south side (naturally.)  Assuming the typical roof overhang of…"
12 hours ago
Patrick Michaelyan replied to Patrick Michaelyan's discussion Hot Upper Stories
"Thanks a lot Ed. And thanks to all who have added their two cents. I think I know where to take…"
13 hours ago
Ed Minch replied to Patrick Michaelyan's discussion Hot Upper Stories
"We have successfully treated this same problem in perhaps 1000 of this same house in the…"
14 hours ago
Craig Savage commented on Craig Savage's video
Thumbnail

What is a Heat Pump Water Heater

"Hello Tom We are working with A.O. Smith, GE and Stiebel Eltron on a Building America task to…"
15 hours ago
Tom Delconte commented on Craig Savage's video
Thumbnail

What is a Heat Pump Water Heater

"Craig: I was serious, since my propane price jumped from .98 to 1.85! according to everyone the GE…"
16 hours ago
Ben Jacobs replied to Jose Macho's discussion Why Are Energy-Saving Home Inprovements Down??
"I think that government support for good ideas results in major benefits over the long haul. Please…"
17 hours ago
Craig Savage commented on Craig Savage's video
Thumbnail

What is a Heat Pump Water Heater

"Hello Tom Not sure if you are being sarcastic, but a serious answer would be that GE is selling…"
19 hours ago
Tom Delconte commented on Craig Savage's video
Thumbnail

What is a Heat Pump Water Heater

"Craig: do you have a diagram of one that will run longer than one year? They don't really seem…"
20 hours ago
Cory Chovanec replied to Bachi Brunato's discussion Boxing and Insulating Around Non-ICAT Cans
"All good points brought up. My advice is not to leave the lights. When you said halogen I think…"
21 hours ago
Jon Haehnel replied to Jose Macho's discussion Why Are Energy-Saving Home Inprovements Down??
"The first 2 answers by Tom and Sean jive with my thinking and experience. Thank you Don for…"
22 hours ago
Tom Smith replied to Patrick Michaelyan's discussion Hot Upper Stories
"The most bang for your buck will come from airsealing the attic plane and sealing the…"
22 hours ago