INFRARED THERMOGRAPHY USERS

Information

INFRARED THERMOGRAPHY USERS

This group is dedicated to knowledge sharing and discussion of infrared thermography for building sciences and energy applications.

Members: 152
Latest Activity: yesterday

Discussion Forum

Google Thermal View? 1 Reply

As most of you know, there is more to an energy audit or energy rating (such as a HERS rating) than just the thermal imaging - but this start up company is using it to get a nationwide database going.........Here's a link to the article on…Continue

Tags: Audit, business, Energy, Google, imaging

Started by Joshua Knittel. Last reply by Nick Helmholdt yesterday.

Infrared Image - What is it? 6 Replies

We thought it'd be fit to share this infrared image we received from group member, CK Ang, in New Zealand. Just wanted to spark some discussion here on what you guys think this image is of, and what the problem could be. A little background on the…Continue

Tags: Fluke, Ti55FT, telephoto, lens, Ang

Started by Fluke Thermal Imaging. Last reply by Dale Sherman Apr 26, 2012.

Timber Home with no effective air barrier 1 Reply

Hi folks,just another image of a brand new timber home without an effective air barrier, and without sealing tapes.…Continue

Started by Davide Lanzoni. Last reply by Sean Lintow Sr Apr 11, 2012.

New article on infrared thermography 1 Reply

The Journal of Light Construction has long been respected as a place where builders can educate themselves and share information. I was recently asked to write an article introducing their readers to thermography and how it can be used in the…Continue

Started by John Snell. Last reply by Jim Klebes Nov 17, 2011.

Moisture detection, a fascinating thermal signature

I don't mean to derail folks from this website to ours (I often send folks here too!) but that is exactly what I'm going to do because www.IRTalk.com has a fascinating discussion about thermal signatures of…Continue

Started by John Snell Sep 9, 2011.

New York first passivhaus ... 4 Replies

... with windows with a better R-value than walls ?…Continue

Started by Davide Lanzoni. Last reply by John Snell Aug 25, 2011.

Using thermal imagers in the summer 5 Replies

Too many thermographers leave their imagers in the case during the summer. This comes, in part, from the way we used to work when imagers were not nearly as sensitive and our understanding of how to use them was limited to winter work.Get the darned…Continue

Started by John Snell. Last reply by Tyson Pischel Jul 7, 2011.

Expert Eye Needed 15 Replies

Hi AllWanted to get the opinion of an expert.Attached is a photo of a customer's window.... as you can see there is a large cold spot above the window... Here's my opinion..am I right?The large horizontal cold spot is thermal bridging from the…Continue

Tags: windows, ir

Started by Matthew P. Last reply by Ed Minch Jun 30, 2011.

IR and Moisture Meters 12 Replies

As many of you know the new RESNET Guidelines are being worked on and I am advocating for the use of Moisture Meters to ensure potential serious moisture problems in sidewalls and building substrate material is not being overlooked when identified…Continue

Started by Bret Monroe. Last reply by allen p tanner Jun 23, 2011.

Certification for RESNET Thermographers 12 Replies

I’m just back from the RESNET national conference in Orlando and I am very excited to report that RESNET certification is now available! What’s needed?• You must be a RESNET Building Performance Auditor or a Rater• You must have 3 months experience…Continue

Started by John Snell. Last reply by Mark Cleminson Mar 22, 2011.

Comment Wall

Comment

You need to be a member of INFRARED THERMOGRAPHY USERS to add comments!

Comment by Michael Stuart on November 10, 2010 at 7:23pm
Dale, another good thought. I believe that the apparatus at the bottom is a heater system. Rod and I also asked the same questions about the bulletin board mounting.

TJ... are you still out there? ;-)
Comment by dale garren on November 10, 2010 at 3:04pm
has anyone checked the water barrier detail around that beam pocket in the masonary portion

what is the apparatus at base of wall?

is the bullitin board "stood off" from wall?
Comment by Michael Stuart on November 10, 2010 at 12:36pm
This is another of TJ's images of the situation... I just applied a low-temperature color alarm to highlight the area of concern.
Comment by Michael Stuart on November 10, 2010 at 12:33pm

Comment by Michael Stuart on November 10, 2010 at 12:31pm
Concrete masonry.
Comment by Rod Hoff on November 10, 2010 at 12:24pm
Are we looking at firred out sheetrock or masonry?
Comment by Michael Stuart on November 10, 2010 at 12:16pm
Thanks for jumping in, Rod! (I am glad that I am not the only one who asks lots of questions.) I believe that the wall is painted... but do not know how permeable the paint is.
Comment by Rod Hoff on November 10, 2010 at 10:19am
Thank you for the invite to join the discussion. If you have not heard of Restoration Consultants allow me please to introduce our company to you. It is owned by Jim Holland, who is well known in the water damage restoration industry. He has been a major player and influencer in the creation of the S500 (water damage restoration standards of practice) and S520 (mold remediation standards) Restoration Consultants Inc provides three services: (1) Environmental consulting, (2) training classes in water damage restoration and mold remediation plus a variety of other classes.. see www.restcon.com (3) distributor of Fluke IR cameras and training in the use of thermography for moisture investigations and building envelope investigations. I teach a 2 day Applied Thermography Training class and a self paced onlline course covering basically the same information. see www.moistureview.com

Relative to the discussion about the anomaly on the masonry wall, temperature differentials, as you know, can be the result of a host of things. It can be a result of evaporative cooling or it can be heat transmission issues (gain/loss). Evaporative cooling happens under the right circumstances as a result of water intrusion that reaches the surface or condensation on the surface. Assuming that a moisture meter was used to verify the presence of moisture (forgive me if you have already answered these questions in your discussions) the big question is 'what's the source?'. In the process of investigating the issue it would be critical to know the make up of the wall. Like Michael said: Is the information board flush with the wall or attached to the wall with strips? Is the wall sheetrock that is firred out from the masonry? And if so, is it painted or covered with vinyl wall paper? It would be helpful to know the ambient temperature inside and outside, the relative humidity inside and outside and the dew point inside and outside. This information can help (using a psychrometric chart) us determine the humidity ratio (specific humidity) and thus the vapor pressure. If there is no vapor barrier and the vapor pressure is greater outside than inside then there will be moisture movement from outside to inside.

To find out if evaporative cooling is happening at the moment you can spray a little water on the wall and use the camera to see if a temperature drop occurs (3-5 degrees probably). If evaporative cooling is happening then the next question is 'Is the surface permeable?'. If, for example, the surface is vinyl wall paper or some non-permeable surface then we can assume that the drop in temperature is not the result of evaporative cooling due to water intrusion. The positive reading on the moisture meter under these circumstances is probably a result of evaporative cooling due to condensation.

Another question would be relative to the type of mechanical heating unit. Is it a water based system or electrical? Does it provide cooling in the summer?

Sorry for all of the questions but the more questions we can ask the more likely we can come to a conclusion.
Comment by Michael Stuart on November 9, 2010 at 10:32am
I'm going to also ask a friend of mine who is a thermographer/educator, specializing in "restoration and remediation" thermography down in Sacramento, to chime in. This is the kind of stuff where he excels.
Comment by Michael Stuart on November 9, 2010 at 10:23am
Interesting... One more question... Is the bulletin board mounted directly to the wall, or is it mounted on any kind of standoffs at all? In other words, is there any appreciable "breathing air" between the board and the wall? No air flow and a wall that does not breath well would possibly lead to condensation issues... but would not necessarily explain the area above the bulletin board.

I guess my biggest question is why would there be an area conducive to condensation at this spot, and nowhere else? Why is this area "cooler" than other areas on the same masonry wall so that condensation will occur when the humidity arises?

Thinking out loud: I am wondering if an initial leak into the wall allowed enough moisture to enter that it just cannot dry out sufficiently (even though the initial leak may have been repaired).

Anyone want to step in with other comments, questions, or hypotheses?

Regards,

Michael
 

Members (152)

 
 
 

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy, under the American Recovery and Reinvestment Act) and brought to you in partnership with Home Energy magazine.

Latest Activity

Dennis Heidner replied to Jose Macho's discussion Why Are Energy-Saving Home Inprovements Down??
"Ben,  the German highway system concept actually started BEFORE Nazi Germany during  the…"
2 hours ago
Stan Kuhn replied to Patrick Michaelyan's discussion Hot Upper Stories
"You note overheating on the south side (naturally.)  Assuming the typical roof overhang of…"
8 hours ago
Patrick Michaelyan replied to Patrick Michaelyan's discussion Hot Upper Stories
"Thanks a lot Ed. And thanks to all who have added their two cents. I think I know where to take…"
8 hours ago
Ed Minch replied to Patrick Michaelyan's discussion Hot Upper Stories
"We have successfully treated this same problem in perhaps 1000 of this same house in the…"
10 hours ago
Craig Savage commented on Craig Savage's video
Thumbnail

What is a Heat Pump Water Heater

"Hello Tom We are working with A.O. Smith, GE and Stiebel Eltron on a Building America task to…"
11 hours ago
Tom Delconte commented on Craig Savage's video
Thumbnail

What is a Heat Pump Water Heater

"Craig: I was serious, since my propane price jumped from .98 to 1.85! according to everyone the GE…"
12 hours ago
Ben Jacobs replied to Jose Macho's discussion Why Are Energy-Saving Home Inprovements Down??
"I think that government support for good ideas results in major benefits over the long haul. Please…"
12 hours ago
Craig Savage commented on Craig Savage's video
Thumbnail

What is a Heat Pump Water Heater

"Hello Tom Not sure if you are being sarcastic, but a serious answer would be that GE is selling…"
15 hours ago
Tom Delconte commented on Craig Savage's video
Thumbnail

What is a Heat Pump Water Heater

"Craig: do you have a diagram of one that will run longer than one year? They don't really seem…"
15 hours ago
Cory Chovanec replied to Bachi Brunato's discussion Boxing and Insulating Around Non-ICAT Cans
"All good points brought up. My advice is not to leave the lights. When you said halogen I think…"
16 hours ago
Jon Haehnel replied to Jose Macho's discussion Why Are Energy-Saving Home Inprovements Down??
"The first 2 answers by Tom and Sean jive with my thinking and experience. Thank you Don for…"
17 hours ago
Tom Smith replied to Patrick Michaelyan's discussion Hot Upper Stories
"The most bang for your buck will come from airsealing the attic plane and sealing the…"
18 hours ago

© 2013   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service