The Snell Group - Level I - Infrared for Building Applications

Event Details

The Snell Group - Level I - Infrared for Building Applications

Time: October 29, 2012 to November 2, 2012
Location: Holiday Inn Express Hotel & Suites
Street: 805 West Arrowood Road
City/Town: Charlotte, NC 28217
Website or Map: http://www.thesnellgroup.com/…
Phone: 1.800.636.9820
Event Type: training, educational, course, certification
Organized By: The Snell Group
Latest Activity: Nov 14, 2011

Export to Outlook or iCal (.ics)

Event Description

Continuing Education Credits/Units Available for This Course.

 

This 32 hour class is designed for energy auditors, weatherization contractors, home inspectors and facility maintenance personnel who use thermal imaging or are considering adding the technology to their program. The class will meet the needs of a thermographer looking to inspect residential and small commercial facilities for insulation defects, air leakage problems and moisture related issues including roof systems. 

Participants will also learn how to apply IR to inspect electrical systems in both residential and small commercial buildings as well as scan mechanical equipment including motors, bearings, pumps, pipes, and HVAC systems.

There are several hands-on simulations and exercises built into the course. While owning an infrared camera is not required for attendance, participants are encouraged to bring their cameras to class. Completion of this course prepares students to successfully apply infrared technology to residential energy audits.

Level I - Infrared for Building Applicationsis designed to meet the proposed BPI and RESNET standards for infrared.  This class also satisfies the Level I infrared educational requirements established by the American Society of Non-Destructive Testing (ASNT) and in Canada is designed to meet the new National Master Specifications (NMS) Section 02 27 13, Thermographic Assessment; Building Envelope.

 

Overview of course topics and applications:    

  • Infrared camera basics
  • Hands-on practice
  • Heat transfer theory
  • Radiometric theory
  • Moisture thermodynamics
  • Principles of building inspections
  • Conduction inspections
  • Air leakage inspections
  • Blower Doors
  • Building moisture inspections
  • Roof moisture inspections
  • Facility electrical and mechanical systems
  • Building standards
  • Report and Analysis software  

Attendees learn inspection techniques based on accepted industry and international inspection procedures.

 

Comment Wall

Comment

RSVP for The Snell Group - Level I - Infrared for Building Applications to add comments!

Join Home Energy Pros

Attending (1)

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Jerry Lawrence posted events
15 hours ago
Morgan M Audetat replied to Bryan Pringle's discussion Dense packed cellulose in basement?
"Right you are. You have to ask: what will the cellulose contribute.  Here in Minneapolis we…"
16 hours ago
Morgan M Audetat replied to Tony Hicks's discussion Slab-on-grade Insulation
"All slabs float. We have been installing radiant floors on various slab constructions since the…"
17 hours ago
Tony Hicks replied to Tony Hicks's discussion Slab-on-grade Insulation
"2" XPS foam. I'd love an R-20. Having foam thick enough to get an R-20 would be…"
17 hours ago
Morgan M Audetat replied to Larry Schaffert's discussion How to correctly insulate exterior wall in a 1900 house?
"Sorry, I did missed the "siding nailed directly to the framing", my grandfather would…"
18 hours ago
Morgan M Audetat replied to Larry Schaffert's discussion How to correctly insulate exterior wall in a 1900 house?
"My own farm house is sided with 1/2" t&g pine boards and vinyl. We foamed then from the…"
18 hours ago
Tony Hicks replied to Tony Hicks's discussion Slab-on-grade Insulation
"Great thought! I think that would work. I'll have to put the cost together and see where I…"
19 hours ago
Danny Gough replied to Tony Hicks's discussion Slab-on-grade Insulation
"This is a tough detail because the foam on the edge of a slab doesn't provide sufficient…"
yesterday