SPECIAL CONTRACTOR CELLULOSE TRAINING EVENT LOCATED AT GREEN JOBS TRAINING CENTER

Event Details

SPECIAL CONTRACTOR CELLULOSE TRAINING EVENT LOCATED AT GREEN JOBS TRAINING CENTER

Time: June 28, 2012 from 8:30am to 4pm
Location: GREEN JOBS TRAINING CENTER
Street: 102-10 159 RD 2ND FL
City/Town: HOWARD BEACH NY 11414
Website or Map: http://GREENJOBTRAININGCENTER…
Phone: 718-659-1205
Event Type: training
Organized By: Green Jobs Training Center
Latest Activity: May 23, 2012

Export to Outlook or iCal (.ics)

Event Description

This is one full day training course, led by Bill Hulstrunk from National Fiber, and is designed to give contractors the proper technique to dense pack and open blow cellulose and in accordance with BPI (Building Performance Institute) and building codes. The course is also eligible for 4 BPI Continuing Ed Credits (CEU’s) for certified attendees.  The course is designed for contractors new to the field or experienced contractors who have not been formally trained in the proper way to install cellulose insulation.  Contractors attending the course will leave with knowledge of machine selection and use, dense pack hose configuration and optimization, how to test a blower machine, how to dense pack walls using the tube insertion method, and be able to pass the test box evaluation.  Learn from the experts at National Fiber about how to improve production and quality of your cellulose installations.

Comment Wall

Comment

RSVP for SPECIAL CONTRACTOR CELLULOSE TRAINING EVENT LOCATED AT GREEN JOBS TRAINING CENTER to add comments!

Join Home Energy Pros

Attending (1)

Videos

  • Add Videos
  • View All

Twitter

Latest Activity

Profile IconBrad Cook, Juan M San Miguel, Marla Meyer and 2 more joined Home Energy Pros
10 hours ago
Chris Clay posted photos
15 hours ago
Chris Clay replied to Blake Shurtz's discussion Testing spillage on induced draft furnace?
"Monitor the pressure in the vent, if its positive in the vent for more than a minute it is most…"
16 hours ago
Chris Clay replied to Blake Shurtz's discussion Testing spillage in mechanical closet?
"You can stand outside and read pressures. Be sure to have extra hose as you need CAZ wrt outside…"
16 hours ago
Chris Clay liked Blake Shurtz's discussion Testing spillage in mechanical closet?
16 hours ago
Diane Jackson posted photos
16 hours ago
Amber Vignieri posted a blog post
18 hours ago
Evan Mills commented on Tom White's video
Thumbnail

The Impact of Green Buildings on Cognitive Function

"Good to see work like this going on.  Findings seem qualitatively consistent with what…"
yesterday

© 2016   Created by Lawrence Berkeley National Laboratory.   Powered by

Badges  |  Report an Issue  |  Terms of Service