This webinar will cover two methods of accurately measuring the air flow rate through air handlers. We will cover the setup and operation of TEC's TrueFlow® Air Handler Flow Meter and the pressure matching method using the Duct Blaster® fan.

The air flow rate through air handlers is an important variable in estimating and optimizing the performance of heat pumps, air conditioners and furnaces. Numerous field studies of installed heating and cooling systems around the United States have found that insufficient air flow across the indoor coil is an extremely common problem. Low air flow can lead to decreased heating and cooling system capacity, increased energy use and comfort problems. This webinar will cover two methods of accurately measuring the air flow rate through air handlers. We will cover the setup and operation of The Energy Conservatory’s TrueFlow® Air Handler Flow Meter and the pressure matching method using the Duct Blaster® fan.

Register now!

Comment Wall

Comment

RSVP for Measuring Air Handler Flow Accurately - TrueFlow to add comments!

Join Home Energy Pros

Attending (1)

Photos

Loading…
  • Add Photos
  • View All

Latest Activity

Profile IconCharlie Ouellette, Karin Haerter and Juan joined Home Energy Pros
2 hours ago
Juan added a discussion to the group Energy Auditing Equipment for Sale, Trade or to Purchase
Thumbnail

Need Energy conservatory Blower door 3 + DG-700

Hello thanks for taking the time to read this post. I am currently looking for a blower door…See More
3 hours ago
Juan joined allen p tanner's group
Thumbnail

Energy Auditing Equipment for Sale, Trade or to Purchase

Discuss the pros and cons of the equipment you are interested in prior to purchase. Post equipment…See More
3 hours ago
Caoimhin P Connell replied to Rodney Fox's discussion Radon: Truth vs. Myth
"Good morning, Mr. Cullen – As I mentioned in another post – for the purposes under…"
4 hours ago
tedkidd replied to Rodney Fox's discussion Radon: Truth vs. Myth
"If putting the house under positive pressure using fresh air helps mitigate not just radon, but…"
5 hours ago
Rich Manning replied to Rodney Fox's discussion Radon: Truth vs. Myth
"Tell them the truth as you know it, and back it up with the facts!!"
6 hours ago
Rich Manning replied to Charles Ryan Weitzel's discussion Oil Fired Boiler Being Used as the Heating Source in Two Air Handlers of a Historic Home
"Yes, its a Hydro-air system. It uses one boiler to supply hot water to the coil in the supply side…"
6 hours ago
tedkidd replied to Rodney Fox's discussion Radon: Truth vs. Myth
";) I love uncovering absuedities... Funny how creatively and vehemently people will argue against…"