ENERGY STAR Version 3 -- Rater Training

Event Details

ENERGY STAR Version 3 -- Rater Training

Time: April 21, 2011 at 8am to April 22, 2011 at 6pm
Location: Grand Junction, CO
Website or Map: http://www.nrglogic.com/estar…
Phone: 970.556.7194
Event Type: training
Organized By: EnergyLogic
Latest Activity: Apr 15, 2011

Export to Outlook or iCal (.ics)

Event Description

Grand Junction, Colorado
Trainer: Glenn Pease
Location: 569 S Westgate Drive, #3
Dates: April 21-22, 2011
Times: 8:00am - 5:00pm
Cost: $425.00
RESNET Professional Development Credits: 18
Minimum Class Size: 7

Training will cover the new requirements of ENERGY STAR for New Homes version 3 program. Detailed presentations will be given on an ENERGY STAR v3 Overview, Thermal Enclosure Rater Checklist, HVAC Quality Installation Rater Checklist, Water Management Builder Checklist, and problem solving for the HERS Rater. At the conclusion of the training each participant will be issued a proctored 2 hour written exam. Students will be issued a certificate of completion with a passing grade of 80% or greater on the exam. EnergyLogic will maintain your records and notify ENERGY STAR of you completion. All participants will be provided a learning management system login described below upon the completion of development.

 

The ENERGY STAR for Homes Version 3 guidelines are being phased in during 2011. Verification partners, including HERS Raters and Field Inspectors, must complete ENERGY STAR Version 3 Rater Training through a RESNET Accredited Training Provider such as EnergyLogic. Effective January 1, 2012, new raters must take this training to become partners. Raters who join prior to 2012 must complete the training by December 31, 2011 to remain ENERGY STAR partners.

EnergyLogic is committed to helping Raters across the country receive training and pass the exam for ENERGY STAR Version 3. As a RESNET Nationally Accredited Training, HERS, & HESP Provider, EnergyLogic brings extensive experience as a trainer, rater, and respected partner of ENERGY STAR. EnergyLogic is the proud recipient of the 2011 Partner of the Year Award for Sustained Excellence.

Comment Wall

Comment

RSVP for ENERGY STAR Version 3 -- Rater Training to add comments!

Join Home Energy Pros

Attending (1)

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.  Home Energy Pros is sponsored by the Better Buildings Residential Network.

Latest Activity

Hannah Finch posted a blog post

Want to Lead a Breakout Session at RaterFest! 2015?

We are adding something new to RaterFest! this year... attendee led breakout sessions on Saturday…See More
2 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"We're in climate zone 5 (near Santa Fe, NM) where it's dry as a bone. Gonna head to that…"
3 hours ago
Bud Poll replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"The two 4500 watt elements will never operate simultaneously.  It will be one or the…"
3 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Correction to this last posting... This model only operates one element at a time, not two in…"
3 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Agreed. Incidentally, I just called tech support at Bradford White (and actually spoke to a…"
3 hours ago
Hans Joachim Preiss replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Rod, Because the tank is not overheating, the behavior is either normal for this tank or there is a…"
4 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"Hey thanks Hans. I didn't know about the benefit of the heatpump units having the elements…"
4 hours ago
Rod Fox replied to Rod Fox's discussion Does calcification affect electric water heater aquastat temperature sensor performance?
"I'm not sure if the tank was flushed at the time of element replacement. I would have hoped…"
4 hours ago

© 2015   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service