CleanEdison BPI Heating Specialist Training CA - Los Angeles Apr 28, 2014

Event Details

CleanEdison BPI Heating Specialist Training CA - Los Angeles Apr 28, 2014

Time: April 28, 2014 at 8am to May 2, 2014 at 5pm
Location: Hampton Inn - Arcadia, CA
Street: 311 East Huntington Drive
City/Town: Los Angeles
Website or Map: http://www.cleanedison.com/co…
Phone: 1-800-658-3656
Event Type: bpi, hers, certification, training
Organized By: CleanEdison
Latest Activity: Nov 28, 2013

Export to Outlook or iCal (.ics)

Event Description

Why Take This Course:

  • This BPI Certification, in conjunction with the BPI Building Analyst certification, will make your company eligible for BPI Accreditation. Only Accreditation allows your company to take advantage of federal, state and local incentives.
  • Heating systems account for 60% of residential energy use. This certification proves that you have the skills to make a significannt reduction in your clients' costs.

Who Should Take This Course:

There are no prerequisites, although the BPI Building Analyst Certification is highly recommended.

What You'll Learn:

CleanEdison's 38-hour Heating Specialist course focuses on understanding how the heating system of a residential building works within the house-as-a-system approach to energy efficiency

Course Objectives:

  • Have an understanding of the various types of heating systems within a home, their components and functions
  • Know the process of completing a BPI energy audit to Heating Specialist standards
  • Be able to conduct safety and performance tests to assess system condition and identify savings opportunities
  • Pass the BPI Heating Specialist written and field exams

Agenda:


Day 1 Course Outline:

  • 9:00 - 9:30 Introduction & Paperwork
  • 9:30 - 10:30 Section 1: Fundamentals of Heating Systems
  • 10:30 - 10:45 Break
  • 10:45 - 12:00 Section 1: Fundamentals of Heating Systems (cont)
  • 12:00 - 1:00 Lunch Break 
  • 1:00 - 2:30 Section 2: Types of Heating Systems
  • 2:30 - 2:45 Break
  • 2:45 - 3:30 Section 2: Types of Heating Systems (cont)
  • 3:30 - 4:00 Sectionn 3: Domestic Hot Water

Day 2 Course Outline:

  • 8:00 - 10:30 Section 4: Health & Satety
  • 10:30 - 10:45 Break
  • 10:45 - 12:00 Section 5: Ducted Systems
  • 12:00 - 1:00 Lunch Break
  • 1:00 - 2:30 Section 6: Manual D
  • 2:30 - 2:45 Break 
  • 2:45 - 4:00 Section 6: Manual D (cont)

Day 3 Course Outline:

  • 9:00 - 10:30 Section 7: Manual J
  • 10:30 - 10:45 Break
  • 10:45 - 12:00 Section 7: Manual K (cont)
  • 12:00 - 1:00 Lunch Break
  • 1:00 - 2:30 Equipment and Practice
  • 2:30 - 2:45 Break
  • 2:45 - 4:00 Equipment and Practice (cont)

Day 4 and 5 Course Outline

  • 9:00 - 12:00 Field Training 
  • 12:00 - 1:00 Lunch Break
  • 1:00 - 4:00 Field Training (cont)

What's Included:

  • 4-day course includes 18 hours of live classroom instruction and 20 hours of field training
  • CleanEdison BPI Heating Specialst Student Manual $95 value
  • All exam fees, written and field exam scheduling
  • CleanEdison Pass Guarantee: If you do not pass the certification exam on your first try, you may re-take the course at no additional cost

Comment Wall

Comment

RSVP for CleanEdison BPI Heating Specialist Training CA - Los Angeles Apr 28, 2014 to add comments!

Join Home Energy Pros

Attending (1)

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Richard Beyer replied to Howard Katzman's discussion UV lights on filters
"Howard, There are numerous manufacturer's who swear these systems work and then you have the…"
4 hours ago
Christopher Morin posted a blog post

How do You Test a TXV?

  Thermostatic Expansion Valves (TEV or TXV), one of the most popular metering devices for…See More
8 hours ago
Howard Katzman posted a discussion

UV lights on filters

 recently saw UV bulb installations in 2 HVAC systems in a home. Each system had the Lennox Healthy…See More
10 hours ago
Don Fitchett joined Michael Stuart's group
Thumbnail

INFRARED THERMOGRAPHY USERS

This group is dedicated to knowledge sharing and discussion of infrared thermography for building…See More
10 hours ago
Don Fitchett commented on Diane Chojnowski's group Pinterest
"While most of our (BIN95.com) energy post and boards are industrial related, there are crossovers…"
10 hours ago
Don Fitchett joined Diane Chojnowski's group
Thumbnail

Pinterest

Do you have a Pinterest board for energy topics?Post the link to your Pinterest energy board in the…See More
11 hours ago
Profile IconJosh Guenther, Deborah Green, Kenneth Brooks and 3 more joined Home Energy Pros
11 hours ago
Jim Gunshinan commented on Jim Gunshinan's blog post My Energy Upgrade California—The Numbers Are In
"Hi David, to answer one question, the crawlspace was covered with thick poly and the seams were…"
11 hours ago
David Eakin commented on Jim Gunshinan's blog post My Energy Upgrade California—The Numbers Are In
"Jim, Maybe a little more detail on the project is in order. You say that your crawlspace is now…"
12 hours ago
Jim Gunshinan commented on Jim Gunshinan's blog post My Energy Upgrade California—The Numbers Are In
"Ed, no problem, I caught your meaning. Ted, I made a judgement that a mini split would be the best…"
12 hours ago
tedkidd commented on Jim Gunshinan's blog post My Energy Upgrade California—The Numbers Are In
"That makes sense.   What are your criteria/metrics for determining what might be the…"
12 hours ago
Ed Voytovich commented on Jim Gunshinan's blog post My Energy Upgrade California—The Numbers Are In
"Yikes!  Not only did I misspell "roof" as "rood," I also meant to more…"
12 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service