CleanEdison BPI Envelope Professional Training WA - Seattle May 12, 2014

Event Details

CleanEdison BPI Envelope Professional Training WA - Seattle May 12, 2014

Time: May 12, 2014 at 8am to May 17, 2014 at 5pm
Location: Best Western Kent
Street: 24415 Russell Road
City/Town: Seattle
Website or Map: http://www.cleanedison.com/co…
Phone: 1-800-658-3656
Event Type: class
Organized By: CleanEdison
Latest Activity: Nov 22, 2013

Export to Outlook or iCal (.ics)

Event Description

Why Take This Course:

  • This BPI Certification, in conjunction with the BPI Building Analyst certification, will make your company eligible to apply for BPI Accreditation. Accreditation allows your firm to take advantage of federal, state and local incentive programs that are available only to firms with accreditation.
  • The classroom portion of the course can be taken either in person or online

Who Should Take This Course:

There are no prerequisites, although the BPI Building Analyst Certification is recommended. Most individuals take the BPI Building Analyst / Envelope Professional Combo.

What You'll Learn:

CleanEdison's 18-hour Envelope Professional course focuses on the thermal and pressure boundaries of a building as well as ways to enhance the building envelope through insulation and air-sealing techniques.

Course Objectives:

  • Have an understanding of the various types of styems within a home, their components and functions and how they inter-operate
  • Know the process of completing a BPI Enevelope Professional and be able to communicate this to Customers
  • Be able to conduct safety and performance tests to assess system condition, identify savings opportunities and prepare a "workscope" with meaningful, cost effective retrofit solutions
  • Pass the BPI Enevlope Professional written and fields exam

Agenda:

Day 1 Course Outline:

  • Section 1: Energy Basics
  • Section 2: Moisture
  • Section 3: Thermal Boundary
  • Section 4: Pressured Boundary
  • Section 5: Mechanical Ventilation
  • Section 6: Pressure Diagnostics
  • Section 7: Forced Air Distribution System
  • Section 8: Combustion Safety
  • Recap of BPI Standards

Day 2 Course Outline:

Field Training

  • Blower Door testing
  • CAZ testing
  • Duct Blaster testing
  • Heat loss determination
  • Recommendations

 

What's Included:

  • 3-day course includes 10 hours of classroom instruction (live or online) and 8 hours of live field training
  • Online materials for self-study before the course
  • CleanEdison Envelope Professional Student Manual ($95 value)
  • A copy of the BPI Technical Standards
  • Live review session with practice questions
  • All exam fees, written and field exam scheduling
  • CleanEdison Pass Guarantee: if you do not pass the certification exam on your first try, you may re-take the course at no additional cost

Comment Wall

Comment

RSVP for CleanEdison BPI Envelope Professional Training WA - Seattle May 12, 2014 to add comments!

Join Home Energy Pros

Attending (1)

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Hal Skinner replied to Hal Skinner's discussion How much heat energy is lost through the floor of a house?
"I found the buildingscience article interesting.  Interesting that they noted the wet bottom…"
10 hours ago
Bud Poll replied to Hal Skinner's discussion How much heat energy is lost through the floor of a house?
"With conduction that ends at the bottom of the joists and convection that is naturally suppressed…"
11 hours ago
Hal Skinner replied to Hal Skinner's discussion How much heat energy is lost through the floor of a house?
"Good morning Bud, Took a quick look at the site and a couple others listed on the Yahoo…"
13 hours ago
Bud Poll replied to Hal Skinner's discussion How much heat energy is lost through the floor of a house?
"Hi Hal, Search "Basecalc basement heat loss".  From memory Canada (nrcan) has/had a…"
14 hours ago
Michael Dunseith posted photos
yesterday
Hal Skinner replied to Hal Skinner's discussion How much heat energy is lost through the floor of a house?
"II just remembered seeing a report by a federal adency, many years ago, that basically said …"
yesterday
Don Fitchett commented on Tom White's video
Thumbnail

Alliant Energy's PowerHouse TV: Sealing Leaky Ductwork

"Very educational. thanks for sharing Tom."
yesterday
Hal Skinner posted a discussion

How much heat energy is lost through the floor of a house?

I am asking this as I do not recall anyone speaking of any study to this end.  Many comments about…See More
yesterday

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service