CleanEdison BPI Envelope Professional Training CA - San Diego Jun 09, 2014

Event Details

CleanEdison BPI Envelope Professional Training CA - San Diego Jun 09, 2014

Time: June 9, 2014 at 8am to June 14, 2014 at 5pm
Location: Holiday Inn Downtown - San Diego
Street: 1617 First Ave
City/Town: San Diego
Website or Map: http://www.cleanedison.com/co…
Phone: 1-800-658-3656
Event Type: class
Organized By: CleanEdison
Latest Activity: Nov 22, 2013

Export to Outlook or iCal (.ics)

Event Description

Why Take This Course:

  • This BPI Certification, in conjunction with the BPI Building Analyst certification, will make your company eligible to apply for BPI Accreditation. Accreditation allows your firm to take advantage of federal, state and local incentive programs that are available only to firms with accreditation.
  • The classroom portion of the course can be taken either in person or online

Who Should Take This Course:

There are no prerequisites, although the BPI Building Analyst Certification is recommended. Most individuals take the BPI Building Analyst / Envelope Professional Combo.

What You'll Learn:

CleanEdison's 18-hour Envelope Professional course focuses on the thermal and pressure boundaries of a building as well as ways to enhance the building envelope through insulation and air-sealing techniques.

Course Objectives:

  • Have an understanding of the various types of styems within a home, their components and functions and how they inter-operate
  • Know the process of completing a BPI Enevelope Professional and be able to communicate this to Customers
  • Be able to conduct safety and performance tests to assess system condition, identify savings opportunities and prepare a "workscope" with meaningful, cost effective retrofit solutions
  • Pass the BPI Enevlope Professional written and fields exam

Agenda:

Day 1 Course Outline:

  • Section 1: Energy Basics
  • Section 2: Moisture
  • Section 3: Thermal Boundary
  • Section 4: Pressured Boundary
  • Section 5: Mechanical Ventilation
  • Section 6: Pressure Diagnostics
  • Section 7: Forced Air Distribution System
  • Section 8: Combustion Safety
  • Recap of BPI Standards

Day 2 Course Outline:

Field Training

  • Blower Door testing
  • CAZ testing
  • Duct Blaster testing
  • Heat loss determination
  • Recommendations

 

What's Included:

  • 3-day course includes 10 hours of classroom instruction (live or online) and 8 hours of live field training
  • Online materials for self-study before the course
  • CleanEdison Envelope Professional Student Manual ($95 value)
  • A copy of the BPI Technical Standards
  • Live review session with practice questions
  • All exam fees, written and field exam scheduling
  • CleanEdison Pass Guarantee: if you do not pass the certification exam on your first try, you may re-take the course at no additional cost

Comment Wall

Comment

RSVP for CleanEdison BPI Envelope Professional Training CA - San Diego Jun 09, 2014 to add comments!

Join Home Energy Pros

Attending (1)

Home Energy Pros

Home Energy Pros was founded by the developers of Home Energy Saver Pro (sponsored by the U.S. Department of Energy,) and brought to you in partnership with Home Energy magazine.

Latest Activity

Mike Kandel commented on David Byrnes's blog post Strategies To Keep Millennials At Their Peak Performance In A Home Performance Company
"David - I'd like to speak with you about this article. Please email me at mkandel@bpi.org."
2 minutes ago
Hal Skinner replied to Richard Beyer's discussion Spontaneous Combustion and Flash Fire regarding Spray Foam Insulation
"This thread has certainly turned into what sounds like  a thread from a fire safety website…"
3 hours ago
Barbara Smith replied to Mike Kandel's discussion Our Homes Suck – And That's Why Our Kids Have Sinus Problems
"RIVEC is a project of the Lawrence Berkeley Lab.  It's a residential ventilation fan…"
3 hours ago
tedkidd replied to Mike Kandel's discussion Our Homes Suck – And That's Why Our Kids Have Sinus Problems
"Richard, I don't "Know" that the earth is not flat, but I'm pretty confident it…"
4 hours ago
Shawn O'Neill replied to Mike Kandel's discussion Our Homes Suck – And That's Why Our Kids Have Sinus Problems
"    Great discussion and points brought up via this "fuse" lit.  More…"
4 hours ago
John Proctor commented on Christopher Morin's blog post How do You Test a TXV?
"Oh yes one more item. There has to be a combination of water and ice to achieve 32 degrees F. That…"
5 hours ago
John Proctor commented on Christopher Morin's blog post How do You Test a TXV?
"Thank you for the nice post. Remember that the important thing is the actual superheat that…"
5 hours ago
Robert (Bob) Bacon commented on Kurt Shafer's blog post What is your opinion about members promoting products here?
"Hi Kurt, Great question - I've been there. I am a business owner specializing in window…"
5 hours ago
daniel manriquez replied to Trip's discussion Starting a Home Weatherization Business. Considering it...
"I would talk to Daniel Tait at http://www.nexusenergycenter.org/ . They do a lot of work with…"
6 hours ago
Tom White's video was featured

Main St Nevada City, Historic Victorian energy upgrade story, Balance Point HP, Debra Little

Energy upgrade of historic 1866 Victorian by Gavin Healy & Dan Perunko of Balance Point Home Performance; Nevada City, CA. Extensive retrofit: attic, wall & ...
7 hours ago
Profile IconRamon Aguirre, John Kane, Bobby Hight and 3 more joined Home Energy Pros
9 hours ago
Jim Gunshinan commented on Jim Gunshinan's blog post My Energy Upgrade California—The Numbers Are In
"Thanks Nate for more good stuff to chew on—and nutritional! We may be running out to Home…"
18 hours ago

© 2014   Created by Lawrence Berkeley National Laboratory.

Badges  |  Report an Issue  |  Terms of Service